130 related articles for article (PubMed ID: 9507480)
1. A doorless entry system for high-energy radiation therapy rooms. Dawson DJ; Wissing WW; Tonks RE Med Phys; 1998 Feb; 25(2):199-201. PubMed ID: 9507480 [TBL] [Abstract][Full Text] [Related]
2. Estimation of the dose at the maze entrance for x-rays from radiotherapy linear accelerators. Al-Affan IA Med Phys; 2000 Jan; 27(1):231-8. PubMed ID: 10659762 [TBL] [Abstract][Full Text] [Related]
3. An alternative to conventional shielding for megavoltage therapy rooms. Fitzgerald LT Med Phys; 1987; 14(5):889-90. PubMed ID: 2824974 [TBL] [Abstract][Full Text] [Related]
4. AAPM code of practice for radiotherapy accelerators: report of AAPM Radiation Therapy Task Group No. 45. Nath R; Biggs PJ; Bova FJ; Ling CC; Purdy JA; van de Geijn J; Weinhous MS Med Phys; 1994 Jul; 21(7):1093-121. PubMed ID: 7968843 [No Abstract] [Full Text] [Related]
5. Shielding considerations for an operating room based intraoperative electron radiotherapy unit. Mills MD; Almond PR; Boyer AL; Ochran TG; Madigan W; Rich TA; Dally EB Int J Radiat Oncol Biol Phys; 1990 May; 18(5):1215-21. PubMed ID: 2112121 [TBL] [Abstract][Full Text] [Related]
6. Influence of shielding blocks on the output of photon beams as a function of energy and type of treatment unit. Van Dam J; Bridier A; Lasselin C; Blanckaert N; Dutreix A Radiother Oncol; 1992 May; 24(1):55-9. PubMed ID: 1620888 [TBL] [Abstract][Full Text] [Related]
7. Shaping of photon beams from electron linear accelerators in radiation therapy. Izewska J Med Phys; 1993; 20(1):171-7. PubMed ID: 8455496 [TBL] [Abstract][Full Text] [Related]
8. Operational radiation protection in high-energy physics accelerators: implementation of ALARA in design and operation of accelerators. Fassò A; Rokni S Radiat Prot Dosimetry; 2009 Nov; 137(1-2):94-9. PubMed ID: 19783841 [TBL] [Abstract][Full Text] [Related]
9. Evaluation of a new high-density shielding material. Barish RJ Health Phys; 1993 Apr; 64(4):412-6. PubMed ID: 8449724 [TBL] [Abstract][Full Text] [Related]
11. Levels of leakage radiation from electron collimators of a linear accelerator. Das KR; Cramb JA; Millar RM; Kenny MB; Patterson WR; Ackerly TL; Perkins AE; Chongkitivitya K Med Phys; 1990; 17(6):1058-63. PubMed ID: 2126336 [TBL] [Abstract][Full Text] [Related]
12. Shielding design for the ceiling of a 6-MV accelerator in an existing facility. Biggs PJ Health Phys; 1987 Apr; 52(4):491-3. PubMed ID: 3106262 [No Abstract] [Full Text] [Related]
13. Neutron dose rate evaluation for medical linear accelerators. Facure A; Falcão RC; Da Silva AX; Crispim VR Radiat Prot Dosimetry; 2004; 111(1):101-3. PubMed ID: 15367778 [TBL] [Abstract][Full Text] [Related]
14. Dose reduction of scattered photons from concrete walls lined with lead: Implications for improvement in design of megavoltage radiation therapy facility mazes. Al-Affan IA; Hugtenburg RP; Bari DS; Al-Saleh WM; Piliero M; Evans S; Al-Hasan M; Al-Zughul B; Al-Kharouf S; Ghaith A Med Phys; 2015 Feb; 42(2):606-614. PubMed ID: 28102603 [TBL] [Abstract][Full Text] [Related]
15. Evaluation of a diode detector array for use as a linear accelerator QC device. Watts RJ Med Phys; 1998 Feb; 25(2):247-50. PubMed ID: 9507488 [TBL] [Abstract][Full Text] [Related]
16. Evaluation of the contribution of capture gamma rays, x-ray leakage, and scatter to the photon dose at the maze door for a high energy medical electron accelerator using a Monte Carlo particle transport code. McGinley PH; Dhaba'an AH; Reft CS Med Phys; 2000 Jan; 27(1):225-30. PubMed ID: 10659761 [TBL] [Abstract][Full Text] [Related]
17. Evaluation of the radiation field and shielding assessment of the experimental area of HIE-ISOLDE. Romanets Y; Bernardes AP; Dorsival A; Gonçalves IF; Kadi Y; di Maria S; Vaz P; Vlachoudis V; Vollaire J Radiat Prot Dosimetry; 2014 Oct; 161(1-4):347-51. PubMed ID: 24591727 [TBL] [Abstract][Full Text] [Related]
18. Shielding design for multiple-energy linear accelerators. Barish RJ Health Phys; 2014 May; 106(5):614-7. PubMed ID: 24670911 [TBL] [Abstract][Full Text] [Related]
19. Shielding assessment of a mobile electron accelerator for intra-operative radiotherapy. Krechetov AS; Goer D; Dikeman K; Daves JL; Mills MD J Appl Clin Med Phys; 2010 Sep; 11(4):3151. PubMed ID: 21081870 [TBL] [Abstract][Full Text] [Related]
20. Leakage radiation from electron applicators on a medical accelerator. Pennington EC; Jani SK; Wen BC Med Phys; 1988; 15(5):763-5. PubMed ID: 3141759 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]