These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

154 related articles for article (PubMed ID: 9508327)

  • 21. Underevaluation of HIV-1 plasma viral load by a commercially available assay in a cluster of patients infected with HIV-1 A/G circulating recombinant form (CRF02).
    Amendola A; Bordi L; Angeletti C; Visco-Comandini U; Abbate I; Cappiello G; Budabbus MA; Eljhawi OA; Mehabresh MI; Girardi E; Antinori A; Ippolito G; Capobianchi MR
    J Acquir Immune Defic Syndr; 2002 Dec; 31(5):488-94. PubMed ID: 12473837
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Low-level viremia associated with the use of TaqMan assay.
    Szabo S; Moffett LE; Cantwell-McNelis K; James CW; Joseph A
    J Int Assoc Physicians AIDS Care (Chic); 2010; 9(4):203-5. PubMed ID: 20530465
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Problems in the interpretation of HIV-1 viral load assays using commercial reagents.
    O'Shea S; Chrystie I; Cranston R; Mullen J; Corbett K; Murphy G; Parry JV; De Ruiter A; Banatvala J
    J Med Virol; 2000 Jun; 61(2):187-94. PubMed ID: 10797373
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Rates of and reasons for failure of commercial human immunodeficiency virus type 1 viral load assays in Brazil.
    Drexler JF; de Souza Luna LK; Pedroso C; Pedral-Sampaio DB; Queiroz AT; Brites C; Netto EM; Drosten C
    J Clin Microbiol; 2007 Jun; 45(6):2061-3. PubMed ID: 17392448
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Comparative performance of three viral load assays on human immunodeficiency virus type 1 (HIV-1) isolates representing group M (subtypes A to G) and group O: LCx HIV RNA quantitative, AMPLICOR HIV-1 MONITOR version 1.5, and Quantiplex HIV-1 RNA version 3.0.
    Swanson P; Soriano V; Devare SG; Hackett J
    J Clin Microbiol; 2001 Mar; 39(3):862-70. PubMed ID: 11230396
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Multicenter study of the LCx HIV RNA quantitative assay--a new competitive reverse transcriptase-PCR which targets pol genomic region of HIV-1 for the measurement of type B, non-type B and group O HIV-1 RNA.
    Troonen H; Grey H; Michel G
    Clin Chem Lab Med; 2002 Jul; 40(7):698-704. PubMed ID: 12241017
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Comprehensive comparison of the VERSANT HIV-1 RNA 3.0 (bDNA) and COBAS AMPLICOR HIV-1 MONITOR 1.5 assays on 1,000 clinical specimens.
    Galli R; Merrick L; Friesenhahn M; Ziermann R
    J Clin Virol; 2005 Dec; 34(4):245-52. PubMed ID: 16286047
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Evaluation of the clinical sensitivities of three viral load assays with plasma samples from a pediatric population predominantly infected with human immunodeficiency virus type 1 subtype G and BG recombinant forms.
    Antunes R; Figueiredo S; Bártolo I; Pinheiro M; Rosado L; Soares I; Lourenço H; Taveira N
    J Clin Microbiol; 2003 Jul; 41(7):3361-7. PubMed ID: 12843094
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Clinical comparison of branched DNA and reverse transcriptase-PCR and nucleic acid sequence-based amplification assay for the quantitation of circulating recombinant form_BC HIV-1 RNA in plasma.
    Pan P; Tao X; Zhang Q; Xing W; Sun X; Pei L; Jiang Y
    AIDS; 2007 Dec; 21 Suppl 8():S27-32. PubMed ID: 18172387
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Discordance between viral loads determined by Roche COBAS AMPLICOR human immunodeficiency virus type 1 monitor (version 1.5) Standard and ultrasensitive assays caused by freezing patient plasma in centrifuged becton-dickinson vacutainer brand plasma preparation tubes.
    Salimnia H; Moore EC; Crane LR; Macarthur RD; Fairfax MR
    J Clin Microbiol; 2005 Sep; 43(9):4635-9. PubMed ID: 16145119
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Impact of HIV type 1 subtype variation on viral RNA quantitation.
    Parekh B; Phillips S; Granade TC; Baggs J; Hu DJ; Respess R
    AIDS Res Hum Retroviruses; 1999 Jan; 15(2):133-42. PubMed ID: 10029245
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Evaluation of a new real-time PCR assay kit for quantification of human immunodeficiency virus RNA in plasma].
    Sudo K; Shima T; Kondo M; Kato S; Mitsunobu I
    Kansenshogaku Zasshi; 2007 Jan; 81(1):1-5. PubMed ID: 17338309
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Comparison of three commercial assays for the quantification of HIV-1 RNA in plasma from individuals infected with different HIV-1 subtypes.
    Chew CB; Herring BL; Zheng F; Browne C; Saksena NK; Cunningham AL; Dwyer DE
    J Clin Virol; 1999 Oct; 14(2):87-94. PubMed ID: 10588451
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Impact of human immunodeficiency virus type 1 (HIV-1) genetic diversity on performance of four commercial viral load assays: LCx HIV RNA Quantitative, AMPLICOR HIV-1 MONITOR v1.5, VERSANT HIV-1 RNA 3.0, and NucliSens HIV-1 QT.
    Swanson P; de Mendoza C; Joshi Y; Golden A; Hodinka RL; Soriano V; Devare SG; Hackett J
    J Clin Microbiol; 2005 Aug; 43(8):3860-8. PubMed ID: 16081923
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Amplicor HIV monitor, NASBA HIV-1 RNA QT and quantiplex HIV RNA version 2.0 viral load assays: a Canadian evaluation.
    Prud'homme IT; Kim JE; Pilon RG; Minkus T; Hawley-Foss N; Cameron W; Rud EW
    J Clin Virol; 1998 Dec; 11(3):189-202. PubMed ID: 9949955
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Clinical evaluation of an in-house reverse transcription-competitive PCR for quantitation of human immunodeficiency virus type 1 RNA in plasma.
    Zazzi M; Romano L; Catucci M; Venturi G; De Milito A; Valensin PE
    J Clin Microbiol; 1999 Feb; 37(2):333-8. PubMed ID: 9889213
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Multisite comparison of reproducibility and recovery from the standard and ultrasensitive Roche AMPLICOR HIV-1 MONITOR assays.
    Brambilla DJ; Granger S; Jennings C; Bremer JW
    J Clin Microbiol; 2001 Mar; 39(3):1121-3. PubMed ID: 11230438
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Quantitation of human immunodeficiency virus type 1 RNA in different biological compartments.
    Shepard RN; Schock J; Robertson K; Shugars DC; Dyer J; Vernazza P; Hall C; Cohen MS; Fiscus SA
    J Clin Microbiol; 2000 Apr; 38(4):1414-8. PubMed ID: 10747117
    [TBL] [Abstract][Full Text] [Related]  

  • 39. The significance of HIV viral load assay precision: a review of the package insert specifications of two commercial kits.
    Chernoff DN
    J Int Assoc Physicians AIDS Care (Chic); 2002; 1(4):134-40. PubMed ID: 12942672
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Comparative evaluation of hepatitis C virus RNA quantitation by branched DNA, NASBA, and monitor assays.
    Lunel F; Cresta P; Vitour D; Payan C; Dumont B; Frangeul L; Reboul D; Brault C; Piette JC; Huraux JM
    Hepatology; 1999 Feb; 29(2):528-35. PubMed ID: 9918931
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.