These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

108 related articles for article (PubMed ID: 9509341)

  • 1. Rotary bending fatigue of coils and wires used in cardiac lead design.
    Altman PA; Meagher JM; Walsh DW; Hoffmann DA
    J Biomed Mater Res; 1998; 43(1):21-37. PubMed ID: 9509341
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Quantitative, low cycle, crack initiation fatigue testing of fine wires and CENELEC standard pacing coil.
    Hildebrand LB; Schmidt JA; Prentice JK; Stotts LJ
    J Biomed Mater Res; 1999; 48(3):251-7. PubMed ID: 10398028
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A study of the fatigue properties of small diameter wires used in intramuscular electrodes.
    Scheiner A; Mortimer JT; Kicher TP
    J Biomed Mater Res; 1991 May; 25(5):589-608. PubMed ID: 1869576
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Stresses from flexure in composite helical implantable leads.
    Meagher JM; Altman P
    Med Eng Phys; 1997 Oct; 19(7):668-73. PubMed ID: 9457700
    [TBL] [Abstract][Full Text] [Related]  

  • 5. High compressive pre-strains reduce the bending fatigue life of nitinol wire.
    Gupta S; Pelton AR; Weaver JD; Gong XY; Nagaraja S
    J Mech Behav Biomed Mater; 2015 Apr; 44():96-108. PubMed ID: 25625888
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Fatigue behavior in Co-Cr-Ni-Mo medical wires drawn with different drawing practices.
    Gvk SS; Liu Z; Tan MJ
    J Mech Behav Biomed Mater; 2019 Nov; 99():134-152. PubMed ID: 31351403
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Embrittlement phenomenon of Ag core MP35N cable as lead conductor in medical device.
    Wang L; Li B; Zhang H
    J Mech Behav Biomed Mater; 2013 Feb; 18():213-8. PubMed ID: 23231759
    [TBL] [Abstract][Full Text] [Related]  

  • 8. High-cycle fatigue behavior of beta-titanium orthodontic wires.
    Murakami T; Iijima M; Muguruma T; Yano F; Kawashima I; Mizoguchi I
    Dent Mater J; 2015; 34(2):189-95. PubMed ID: 25740165
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Fatigue failure of as-received and retrieved NiTi orthodontic archwires.
    Bourauel C; Scharold W; Jäger A; Eliades T
    Dent Mater; 2008 Aug; 24(8):1095-101. PubMed ID: 18289660
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effects of raw material and rotational speed on the cyclic fatigue of ProFile Vortex rotary instruments.
    Gao Y; Shotton V; Wilkinson K; Phillips G; Johnson WB
    J Endod; 2010 Jul; 36(7):1205-9. PubMed ID: 20630300
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dynamic Torsional and Cyclic Fracture Behavior of ProFile Rotary Instruments at Continuous or Reciprocating Rotation as Visualized with High-speed Digital Video Imaging.
    Tokita D; Ebihara A; Miyara K; Okiji T
    J Endod; 2017 Aug; 43(8):1337-1342. PubMed ID: 28578890
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Rotary-bending fatigue characteristics of medical-grade Nitinol wire.
    Pelton AR; Fino-Decker J; Vien L; Bonsignore C; Saffari P; Launey M; Mitchell MR
    J Mech Behav Biomed Mater; 2013 Nov; 27():19-32. PubMed ID: 23838356
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Physical and mechanical characterization and the influence of cyclic loading on the behaviour of nickel-titanium wires employed in the manufacture of rotary endodontic instruments.
    Bahia MG; Martins RC; Gonzalez BM; Buono VT
    Int Endod J; 2005 Nov; 38(11):795-801. PubMed ID: 16218971
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A fatigue-resistant microcable for small diameter leads of active implantable medical devices.
    Jung M; Liu Z; Gvk SS; Julien E; Shan N
    J Mech Behav Biomed Mater; 2021 Apr; 116():104348. PubMed ID: 33571841
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of the mechanical behaviour of PathFile and ProGlider pathfinding nickel-titanium rotary instruments.
    Elnaghy AM; Elsaka SE
    Int Endod J; 2015 Sep; 48(9):894-901. PubMed ID: 25266920
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A mechanical analysis informed fractography study on load-specific fatigue behaviors of Pt-Ir coils used in implantable medical leads.
    Li L; Jiang C; Wang H; Xie H; Li L
    J Mech Behav Biomed Mater; 2021 Apr; 116():104364. PubMed ID: 33545415
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of environment on fatigue failure of controlled memory wire nickel-titanium rotary instruments.
    Shen Y; Qian W; Abtin H; Gao Y; Haapasalo M
    J Endod; 2012 Mar; 38(3):376-80. PubMed ID: 22341078
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Synergistic effect of wire bending and salivary pH on surface properties and mechanical properties of orthodontic stainless steel archwires.
    Hobbelink MG; He Y; Xu J; Xie H; Stoll R; Ye Q
    Prog Orthod; 2015; 16():37. PubMed ID: 26501207
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Influence of cyclic torsional preloading on cyclic fatigue resistance of nickel - titanium instruments.
    Pedullà E; Lo Savio F; Boninelli S; Plotino G; Grande NM; Rapisarda E; La Rosa G
    Int Endod J; 2015 Nov; 48(11):1043-50. PubMed ID: 25353957
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Low-cycle fatigue of rotary NiTi endodontic instruments in hypochlorite solution.
    Cheung GS; Darvell BW
    Dent Mater; 2008 Jun; 24(6):753-9. PubMed ID: 17996288
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.