These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

98 related articles for article (PubMed ID: 9510297)

  • 41. A rational algorithm for duplex scan surveillance after carotid endarterectomy.
    Roth SM; Back MR; Bandyk DF; Avino AJ; Riley V; Johnson BL
    J Vasc Surg; 1999 Sep; 30(3):453-60. PubMed ID: 10477638
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Routine early postoperative duplex scanning is unnecessary following uncomplicated carotid endarterectomy.
    Skelly CL; Meyerson SL; Curi MA; Desai TR; Bassiouny HS; McKinsey JF; Gewertz BL; Schwartz LB
    Vasc Endovascular Surg; 2002; 36(2):115-22. PubMed ID: 11951098
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Carotid Ultrasound Examinations: Indications Correlated With Abnormal Findings.
    Naidich JB; Weiss A; Grimaldi GM; Kohn N; Naidich JJ; Pellerito JS
    Ultrasound Q; 2018 Sep; 34(3):183-189. PubMed ID: 30020270
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Duplex Doppler sonography of the carotid artery: velocity measurements in an artery with contralateral stenosis.
    Grajo JR; Barr RG
    Ultrasound Q; 2007 Sep; 23(3):199-202. PubMed ID: 17805190
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Persistent hypoglossal artery: An anomaly leading to false-positive carotid duplex sonography.
    Widmann MD; Sumpio BE
    Ann Vasc Surg; 1992 Mar; 6(2):176-8. PubMed ID: 1599838
    [TBL] [Abstract][Full Text] [Related]  

  • 46. [Segmental occlusion of the internal carotid artery with collateral reinjection downstream from the carotid sinus].
    Böge G; Prodhomme O; Piciche M; Dauzat M; Laroche JP; Quéré I; Vernhet H
    J Mal Vasc; 2007 Feb; 32(1):47-52. PubMed ID: 17276640
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Carotid string sign resulting from an aberrant branch of the internal carotid artery.
    Brooks AJ; Behm GM; Baxter BT; Lynch TG
    J Cardiovasc Surg (Torino); 1998 Apr; 39(2):163-5. PubMed ID: 9638998
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Use of limited color-flow duplex for a carotid screening project.
    Carsten CG; Elmore JR; Franklin DP; Thomas DD; Mordan F; Wood GC
    Am J Surg; 1999 Aug; 178(2):173-6. PubMed ID: 10487273
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Transcranial Doppler sonography and magnetic resonance angiography in the assessment of collateral hemispheric flow in patients with carotid artery disease.
    Anzola GP; Gasparotti R; Magoni M; Prandini F
    Stroke; 1995 Feb; 26(2):214-7. PubMed ID: 7831690
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Detection of total occlusion, string sign, and preocclusive stenosis of the internal carotid artery by color-flow duplex scanning.
    Mansour MA; Mattos MA; Hood DB; Hodgson KJ; Barkmeier LD; Ramsey DE; Sumner DS
    Am J Surg; 1995 Aug; 170(2):154-8. PubMed ID: 7631921
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Utility of routine carotid duplex screening in patients who have claudication.
    Marek J; Mills JL; Harvich J; Cui H; Fujitani RM
    J Vasc Surg; 1996 Oct; 24(4):572-7; discussion 577-9. PubMed ID: 8911405
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Magnetic resonance angiography in the evaluation of carotid stent patency.
    Rizzo JA; Dodge A; White P; Martin ED
    Perspect Vasc Surg Endovasc Ther; 2010 Dec; 22(4):261-3. PubMed ID: 21411467
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Carotid Doppler velocity measurements and anatomic stenosis: correlation is futile.
    Beach KW; Leotta DF; Zierler RE
    Vasc Endovascular Surg; 2012 Aug; 46(6):466-74. PubMed ID: 22786979
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Ageing affects the accuracy of duplex ultrasonography in grading carotid artery stenosis.
    Schreuder FH; Mess WH; Hoeks AP
    Cerebrovasc Dis; 2009; 27(1):75-83. PubMed ID: 19018141
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Stent-angioplasty for internal-to-external carotid artery anastomotic stenosis: a case report.
    Lesley WS; Buckley CJ
    Vasc Endovascular Surg; 2007; 41(3):262-4. PubMed ID: 17595396
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Screening for asymptomatic internal carotid artery stenosis: duplex criteria for discriminating 60% to 99% stenosis.
    Moneta GL; Edwards JM; Papanicolaou G; Hatsukami T; Taylor LM; Strandness DE; Porter JM
    J Vasc Surg; 1995 Jun; 21(6):989-94. PubMed ID: 7776480
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Transcranial Doppler sonography: collateral pathways in internal carotid artery obstructions.
    Rosenkranz K; Langer R; Felix R
    Angiology; 1991 Oct; 42(10):819-26. PubMed ID: 1952270
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Duplex ultrasound velocity criteria for the stented carotid artery.
    Lal BK; Hobson RW; Tofighi B; Kapadia I; Cuadra S; Jamil Z
    J Vasc Surg; 2008 Jan; 47(1):63-73. PubMed ID: 18178455
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Evaluation of carotid artery stenosis: is duplex ultrasonography sufficient?
    Muto PM; Welch HJ; Mackey WC; O'Donnell TF
    J Vasc Surg; 1996 Jul; 24(1):17-22; discussion 22-4. PubMed ID: 8691519
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Duplex criteria for determining ≥50% and ≥80% internal carotid artery stenosis following carotid endarterectomy with patch angioplasty.
    Aburahma AF
    Vascular; 2011 Feb; 19(1):15-20. PubMed ID: 21489922
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.