BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

282 related articles for article (PubMed ID: 9511465)

  • 1. Matrix effect in quantitative LC/MS/MS analyses of biological fluids: a method for determination of finasteride in human plasma at picogram per milliliter concentrations.
    Matuszewski BK; Constanzer ML; Chavez-Eng CM
    Anal Chem; 1998 Mar; 70(5):882-9. PubMed ID: 9511465
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS.
    Matuszewski BK; Constanzer ML; Chavez-Eng CM
    Anal Chem; 2003 Jul; 75(13):3019-30. PubMed ID: 12964746
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Determination of a cyclic hexapeptide, a novel antifungal agent, in human plasma by high-performance liquid chromatography with ion spray and turbo ion spray tandem mass spectrometric detection.
    Chavez-Eng CM; Schwartz M; Constanzer ML; Matuszewski BK
    J Chromatogr B Biomed Sci Appl; 1999 Jan; 721(2):229-38. PubMed ID: 10052695
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Standard line slopes as a measure of a relative matrix effect in quantitative HPLC-MS bioanalysis.
    Matuszewski BK
    J Chromatogr B Analyt Technol Biomed Life Sci; 2006 Jan; 830(2):293-300. PubMed ID: 16310419
    [TBL] [Abstract][Full Text] [Related]  

  • 5. High perfomance liquid chromatography in pharmaceutical analyses.
    Nikolin B; Imamović B; Medanhodzić-Vuk S; Sober M
    Bosn J Basic Med Sci; 2004 May; 4(2):5-9. PubMed ID: 15629016
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Picogram determination of finasteride in human plasma and semen by high-performance liquid chromatography with atmospheric-pressure chemical-ionization tandem mass spectrometry.
    Constanzer ML; Chavez CM; Matuszewski BK
    J Chromatogr B Biomed Appl; 1994 Aug; 658(2):281-7. PubMed ID: 7820256
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Simultaneous determination of Aprepitant and two metabolites in human plasma by high-performance liquid chromatography with tandem mass spectrometric detection.
    Chavez-Eng CM; Constanzer ML; Matuszewski BK
    J Pharm Biomed Anal; 2004 Sep; 35(5):1213-29. PubMed ID: 15336366
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Determination of a prostaglandin D2 antagonist and its acyl glucuronide metabolite in human plasma by high performance liquid chromatography with tandem mass spectrometric detection--a lack of MS/MS selectivity between a glucuronide conjugate and a phase I metabolite.
    Schwartz MS; Desai RB; Bi S; Miller AR; Matuszewski BK
    J Chromatogr B Analyt Technol Biomed Life Sci; 2006 Jun; 837(1-2):116-24. PubMed ID: 16716772
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of the sample matrix on the determination of indinavir in human urine by HPLC with turbo ion spray tandem mass spectrometric detection.
    Fu I; Woolf EJ; Matuszewski BK
    J Pharm Biomed Anal; 1998 Nov; 18(3):347-57. PubMed ID: 10096829
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Quantitative determination of Orlistat (tetrahydrolipostatin, Ro 18-0647) in human plasma by high-performance liquid chromatography coupled with ion spray tandem mass spectrometry.
    Bennett PK; Li YT; Edom R; Henion J
    J Mass Spectrom; 1997 Jul; 32(7):739-49. PubMed ID: 9241856
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Determination of dextromethorphan and its metabolite dextrorphan in human urine using high performance liquid chromatography with atmospheric pressure chemical ionization tandem mass spectrometry: a study of selectivity of a tandem mass spectrometric assay.
    Constanzer ML; Chavez-Eng CM; Fu I; Woolf EJ; Matuszewski BK
    J Chromatogr B Analyt Technol Biomed Life Sci; 2005 Feb; 816(1-2):297-308. PubMed ID: 15664362
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Simultaneous determination of a novel KDR kinase inhibitor and its N-oxide metabolite in human plasma using 96-well solid-phase extraction and liquid chromatography/tandem mass spectrometry.
    Xu Y; Du L; Soli ED; Braun MP; Dean DC; Musson DG
    J Chromatogr B Analyt Technol Biomed Life Sci; 2005 Mar; 817(2):287-96. PubMed ID: 15686997
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Determination of rofecoxib (MK-0966), a cyclooxygenase-2 inhibitor, in human plasma by high-performance liquid chromatography with tandem mass spectrometric detection.
    Chavez-Eng CM; Constanzer ML; Matuszewski BK
    J Chromatogr B Biomed Sci Appl; 2000 Oct; 748(1):31-9. PubMed ID: 11092584
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Finasteride in biological fluids: extraction and separation by a graphitized carbon black cartridge and quantification by high-performance liquid chromatography.
    Carlucci G; Mazzeo P
    J Chromatogr B Biomed Sci Appl; 1997 May; 693(1):245-8. PubMed ID: 9200544
    [TBL] [Abstract][Full Text] [Related]  

  • 15. High-performance liquid chromatographic-tandem mass spectrometric evaluation and determination of stable isotope labeled analogs of rofecoxib in human plasma samples from oral bioavailability studies.
    Chavez-Eng CM; Constanzer ML; Matuszewski BK
    J Chromatogr B Analyt Technol Biomed Life Sci; 2002 Feb; 767(1):117-29. PubMed ID: 11863283
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A rapid and specific assay, based on liquid chromatography-atmospheric pressure chemical ionization mass spectrometry, for the determination of MK-434 (a 5 alpha-reductase inhibitor) and its metabolites in plasma.
    Olah TV; Gilbert JD; Barrish A; Greber TF; McLoughlin DA
    J Pharm Biomed Anal; 1994 May; 12(5):705-12. PubMed ID: 7948192
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Development, validation and transfer of a hydrophilic interaction liquid chromatography/tandem mass spectrometric method for the analysis of the tobacco-specific nitrosamine metabolite NNAL in human plasma at low picogram per milliliter concentrations.
    Pan J; Song Q; Shi H; King M; Junga H; Zhou S; Naidong W
    Rapid Commun Mass Spectrom; 2004; 18(21):2549-57. PubMed ID: 15468159
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Low level determination of a novel 4-azasteroid and its carboxylic acid metabolite in human plasma and semen using high-performance liquid chromatography with atmospheric pressure chemical ionization tandem mass spectrometry.
    Constanzer ML; Chavez CM; Matuszewski BK; Carlin J; Graham D
    J Chromatogr B Biomed Sci Appl; 1997 May; 693(1):117-29. PubMed ID: 9200525
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Determination of finasteride in human plasma by liquid-liquid extraction and high-performance liquid chromatography.
    Ptácek P; Macek J; Klíma J
    J Chromatogr B Biomed Sci Appl; 2000 Feb; 738(2):305-10. PubMed ID: 10718648
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Synthesis of 5,6,6-[2H3]finasteride and quantitative determination of finasteride in human plasma at picogram level by an isotope-dilution mass spectrometric method.
    Guarna A; Danza G; Bartolucci G; Marrucci A; Dini S; Serio M
    J Chromatogr B Biomed Appl; 1995 Dec; 674(2):197-204. PubMed ID: 8788149
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.