These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

180 related articles for article (PubMed ID: 9513250)

  • 1. An investigation into vascular prosthesis modified with an electron beam.
    Lowkis B; Szymonowicz M; Rutkowski J
    Polim Med; 1997; 27(3-4):19-26. PubMed ID: 9513250
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An assessment of athrombogenic properties of electret polyethylene film.
    Lowkis B; Szymonowicz M
    Polim Med; 1998; 28(1-2):3-13. PubMed ID: 9513254
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of the electret-blood contact time on the adhesion of human blood platelets.
    Lowkis B; Szymonowicz M
    Polim Med; 1993; 23(3-4):21-30. PubMed ID: 8029154
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Does the liquid method of electret forming influence the adhesion of blood platelets?
    Lowkis B; Szymanowicz M
    Polim Med; 1995; 25(1-2):3-13. PubMed ID: 7479426
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of electric charge on the adhesion of human blood platelets.
    Lowkis B; Szymonowicz M
    Polim Med; 1993; 23(3-4):15-9. PubMed ID: 8029153
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Effect of different vascular prosthesis materials on blood platelets, blood clotting and fibrinolysis].
    Głowiński S; Worowski K; Worowska A; Raczyński K; Głowiński J; Kondracki S
    Polim Med; 1992; 22(4):17-29. PubMed ID: 1305964
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Influence of distribution of density of surface charge on adhesion of human blood platelets.
    Lowkis B; Szymonowicz M
    Polim Med; 1994; 24(1-2):21-9. PubMed ID: 7971531
    [No Abstract]   [Full Text] [Related]  

  • 8. Ex vivo and in vitro platelet adhesion on RFGD deposited polymers.
    Kiaei D; Hoffman AS; Hanson SR
    J Biomed Mater Res; 1992 Mar; 26(3):357-72. PubMed ID: 1613026
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Antithrombogenic polynitrosated polyester/poly(methyl methacrylate) blend for the coating of blood-contacting surfaces.
    Seabra AB; da Silva R; de Souza GF; de Oliveira MG
    Artif Organs; 2008 Apr; 32(4):262-7. PubMed ID: 18370938
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Clinical evaluation of a polyester vascular prosthesis impregnated with albumins from material of the Vascular Surgical Clinic AM in Wrocław in the years 1994-1997. Introductory report].
    Barć P; Dorobisz A; Patrzałek D; Wołyniec A; Pupka A; Chudoba P; Polak W; Kałuza G
    Polim Med; 1997; 27(3-4):33-7. PubMed ID: 9513252
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Differentiated biocompatible design of luminal and outer graft surfaces. Photocurable extracellular matrices, fabrication, and cellular response.
    Kito H; Nakajima N; Matsuda T
    ASAIO J; 1993; 39(3):M506-11. PubMed ID: 8268588
    [TBL] [Abstract][Full Text] [Related]  

  • 12. No platelet can adhere--largely improved blood compatibility on nanostructured superhydrophobic surfaces.
    Sun T; Tan H; Han D; Fu Q; Jiang L
    Small; 2005 Oct; 1(10):959-63. PubMed ID: 17193377
    [No Abstract]   [Full Text] [Related]  

  • 13. [Comparison of cathepsin D activity of DALLON-standard and DALLON-double velour grafts implanted into the abdominal aorta].
    Głowiński S; Worowski K; Raczyński K
    Polim Med; 1992; 22(4):63-8. PubMed ID: 1305967
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Attempts at modification of the polyester vascular prosthesis].
    Paluch D; Staniszewska-Kuś J; Rutowski R; Szymonowicz M; Solski L
    Polim Med; 1992; 22(4):77-86. PubMed ID: 1305969
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Albumin coated and critical point dried polyester prostheses as substitutes in the thoracic aorta of dogs.
    Guidoin RG; King MW; Awad J; Martin L; Domurado D; Marois M; Sigot-Luizard MF; Gosselin C; Gunasekera K; Gagnon D
    Trans Am Soc Artif Intern Organs; 1983; 29():290-5. PubMed ID: 6673241
    [No Abstract]   [Full Text] [Related]  

  • 16. Luminal surface microgeometry affects platelet adhesion in small-diameter synthetic grafts.
    Losi P; Lombardi S; Briganti E; Soldani G
    Biomaterials; 2004 Aug; 25(18):4447-55. PubMed ID: 15046935
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Local activation of blood coagulation by polyester prostheses implanted into defects of the abdominal aorta of dogs.
    Głowiński S; Worowski K
    Polim Med; 1977; 7(4):241-3. PubMed ID: 614538
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Tissue reaction following the implantation of a DALLON H vascular prosthesis in the thoracic aorta defect. Experimental tests.
    Milewski A; Staniszewska-Kuś J; Rutowski R; Solski L; Pielka S
    Polim Med; 2002; 32(1-2):23-40. PubMed ID: 12391781
    [TBL] [Abstract][Full Text] [Related]  

  • 19. In vivo biocompatibility of sulfonated PEO-grafted polyurethanes for polymer heart valve and vascular graft.
    Han DK; Park K; Park KD; Ahn KD; Kim YH
    Artif Organs; 2006 Dec; 30(12):955-9. PubMed ID: 17181836
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Intraoperative studies and studies on selected parameters of coagulation and fibrinolysis following implantation of DALLON H prostheses with greater surface wettability.
    Paluch D; Szymonowicz M; Rutowski R; Milewski A; Pielka S; Solski L; Raczyński K
    Polim Med; 2002; 32(1-2):65-79. PubMed ID: 12391783
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.