These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
63 related articles for article (PubMed ID: 9514468)
1. Limitation of long-term atrial pacing via floating ring electrode using overlapping biphasic impulse stimulation in ambulatory-paced patients. Tse HF; Lau CP; Leung SK Am J Cardiol; 1998 Mar; 81(5):645-7. PubMed ID: 9514468 [TBL] [Abstract][Full Text] [Related]
2. Single lead DDD system: a comparative evaluation of unipolar, bipolar, and overlapping biphasic stimulation and the effects of right atrial floating electrode location on atrial pacing and sensing thresholds. Tse HF; Lau CP; Leung SK; Leung Z; Mehta N Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 2):1758-63. PubMed ID: 8945035 [TBL] [Abstract][Full Text] [Related]
3. Atrial sensing and pacing with a single pass ventricular lead. Tse HF; Lau CP Chin Med J (Engl); 1998 Dec; 111(12):1118-23. PubMed ID: 11263378 [TBL] [Abstract][Full Text] [Related]
4. Current density distribution by ring and diagonally arranged half-ring electrodes in bipolar and overlapping biphasic impulse stimulation. Suzuki S; Ishikawa N; Inoue Y; Cho Y; Inoue S; Hashizume K; Aoki Y Pacing Clin Electrophysiol; 2010 Sep; 33(9):1063-73. PubMed ID: 20456642 [TBL] [Abstract][Full Text] [Related]
5. Long-term performance of steroid-eluting lead in dual chamber pacing. Hua W; Mond H Chin Med Sci J; 1997 Jun; 12(2):118-20. PubMed ID: 11324497 [TBL] [Abstract][Full Text] [Related]
6. [Single-lead DDD cardiac pacing: state of the art and future perspectives]. Romanò M; Spinelli A; Grieco A Ital Heart J Suppl; 2000 Dec; 1(12):1553-60. PubMed ID: 11221584 [TBL] [Abstract][Full Text] [Related]
7. A new approach for DDD(R) pacing using a single-pass DDD lead. Naegeli B; Straumann E; Gerber A; Niederhäuser U; Bertel O Am J Cardiol; 1997 Sep; 80(5):643-5. PubMed ID: 9295001 [TBL] [Abstract][Full Text] [Related]
8. First results of the Canadian and European Single lead DDD Studies. A report of two multicenter studies on Vena Cava Atrial Stimulation (VECATS). Res JC; Lau C; Pacing Clin Electrophysiol; 2000 Nov; 23(11 Pt 2):1804-8. PubMed ID: 11139929 [TBL] [Abstract][Full Text] [Related]
9. Differences in pacing from the atrial appendage and the lateral atrial free wall on left ventricular filling and haemodynamics during DDD pacing. van Campen CM; de Cock CC; Kamp O; Visser CA Europace; 2001 Jan; 3(1):52-5. PubMed ID: 11271952 [TBL] [Abstract][Full Text] [Related]
10. [Epicardial atrial pacing using an active fixation bipolar endocardial lead in children]. Noma M; Atsumi N; Hiramatsu Y; Horigome H; Takahashi M; Enomoto Y; Matsushita S; Sakakibara Y Kyobu Geka; 2007 Feb; 60(2):117-20. PubMed ID: 17305077 [TBL] [Abstract][Full Text] [Related]
12. Long-term performance of single-pass physiological pacing. Kar AK; Roy D; Mondal M; Dutta I Indian Heart J; 2001; 53(4):477-80. PubMed ID: 11759938 [TBL] [Abstract][Full Text] [Related]
13. Feasibility of dual-chamber (DDD) pacing via a single-pass (VDD) pacing lead employing a floating atrial ring (dipole): case series, future considerations, and refinements. Kassotis J; Voigt L; Mongwa M; Reddy CV Angiology; 2005; 56(3):323-9. PubMed ID: 15889201 [TBL] [Abstract][Full Text] [Related]
14. Inadvertent transvenous left ventricular pacing through an unsuspected atrial septal defect. Kumar S; Ghosh P; Ghosh AK; Banerjee S; Banerjee S; Majumder S J Indian Med Assoc; 2006 Sep; 104(9):522-4. PubMed ID: 17388012 [TBL] [Abstract][Full Text] [Related]