These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 9517158)

  • 1. [Early detection of obstructive sleep apnea by statistical analysis of phase angle changes in respiratory tract impedance].
    Reisch S; Timmer J; Rühle KH; Geiger K; Guttmann J
    Biomed Tech (Berl); 1997; 42 Suppl():295-7. PubMed ID: 9517158
    [No Abstract]   [Full Text] [Related]  

  • 2. A simplified method for monitoring respiratory impedance during continuous positive airway pressure.
    Navajas D; Duvivier C; Farré R; Peslin R
    Eur Respir J; 2000 Jan; 15(1):185-91. PubMed ID: 10678644
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Self-adjusting nasal continuous positive airway pressure therapy based on measurement of impedance: A comparison of two different maximum pressure levels.
    Randerath WJ; Parys K; Feldmeyer F; Sanner B; Rühle KH
    Chest; 1999 Oct; 116(4):991-9. PubMed ID: 10531164
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Extent of variations in minimal CPAP pressure requirements during a single night].
    Hein H; Müllauer B; Magnussen H
    Pneumologie; 1997 Aug; 51 Suppl 3():786-8. PubMed ID: 9340642
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Effect of automatically titrated CPAP systems on sleep and respiration in sleep apnea syndrome].
    Hoster M; Schlenker E; Rühle KH
    Wien Med Wochenschr; 1996; 146(13-14):385-7. PubMed ID: 9012194
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Long-term analysis of respiration in sleep].
    Schüttler F; Juhász J; Pankow W; Penzel T
    Wien Med Wochenschr; 1996; 146(13-14):382-4. PubMed ID: 9012193
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Home assessment of sleep disorders by portable monitoring.
    Broughton R; Fleming J; Fleetham J
    J Clin Neurophysiol; 1996 Jul; 13(4):272-84. PubMed ID: 8858490
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Identifying respiratory events and artifacts using oscillatory impedance measurement in aPAP therapy.
    Harms R; Graetz B; Schöller B
    Biomed Tech (Berl); 2002; 47 Suppl 1 Pt 1():313-4. PubMed ID: 12451850
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Significance of oscillatory impedance in etiological determination of arousal in sleep related respiratory disorders].
    Schlenker E; Hoster M; Rühle KH
    Wien Med Wochenschr; 1996; 146(13-14):379-81. PubMed ID: 9012192
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Practice parameters for the use of portable recording in the assessment of obstructive sleep apnea. Standards of Practice Committee of the American Sleep Disorders Association.
    Sleep; 1994 Jun; 17(4):372-7. PubMed ID: 7973322
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Midsagittal jaw movements as a sleep/wake marker.
    Senny F; Destiné J; Poirrier R
    IEEE Trans Biomed Eng; 2009 Feb; 56(2):303-9. PubMed ID: 19342328
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Analog circuit for real-time computation of respiratory mechanical impedance in sleep studies.
    Farré R; Rotger M; Montserrat JM; Navajas D
    IEEE Trans Biomed Eng; 1997 Nov; 44(11):1156-9. PubMed ID: 9353995
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Objective measurement of work of breathing with CPAP and BiLEVEL ventilation].
    Negele C; Genger H; Eichmeier J
    Biomed Tech (Berl); 1997; 42 Suppl():301-4. PubMed ID: 9517161
    [No Abstract]   [Full Text] [Related]  

  • 14. [Spectral analysis of blood pressure in patients with sleep related respiratory disorders].
    Penzel T; Brandenburg U; Greinke S; Grote L
    Wien Med Wochenschr; 1996; 146(13-14):359-61. PubMed ID: 9012184
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Validating a 7-channel ambulatory polygraph unit. 2: Simultaneous polysomnography].
    Verse T; Pirsig W; Junge-Hülsing B; Kroker B
    HNO; 1999 Apr; 47(4):256-61. PubMed ID: 10407730
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ambulatory management of patients with sleep apnea: is there a place for portable monitor testing?
    Sunwoo B; Kuna ST
    Clin Chest Med; 2010 Jun; 31(2):299-308. PubMed ID: 20488288
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Detecting blood pressure variation using spectral analysis in obstructive sleep apnea syndrome with and without nCPAP therapy].
    Brandenburg U; Greinke S; Penzel T; Peter JH
    Pneumologie; 1995 Mar; 49 Suppl 1():116-20. PubMed ID: 7617592
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Machine-assisted detection of individually effective minimal CPAP pressure using the Vitalog HMS 5000 monitor].
    Juhász J; Schillen J; Urbigkeit A; Penzel T; Becker H; Peter JH
    Pneumologie; 1995 Mar; 49 Suppl 1():199-204. PubMed ID: 7617615
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Forced oscillation technique in the sleep apnoea/hypopnoea syndrome: identification of respiratory events and nasal continuous positive airway pressure titration.
    Lemes LN; Melo PL
    Physiol Meas; 2003 Feb; 24(1):11-25. PubMed ID: 12636184
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Parameters for determining the effective treatment pressure in nCPAP therapy of sleep apnea].
    Becker H; Stammnitz A; Ploch TH; Peter JH
    Pneumologie; 1995 Mar; 49 Suppl 1():195-8. PubMed ID: 7617614
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.