69 related articles for article (PubMed ID: 951832)
1. Platelet response to long-term spiral coiled membrane lung bypass without heparin using a carbon silicone rubber membrane.
Kolobow T; Tomlinson T; Pierce J; Gattinoni L
Trans Am Soc Artif Intern Organs; 1976; 22():110-8. PubMed ID: 951832
[No Abstract] [Full Text] [Related]
2. Blood compatibility of methyl, methyl vinyl, methyl phenyl, and trifluoropropylmethylvinyl silicone rubber without silica fillers in the spiral-coiled membrane lung.
Kolobow T; Tomlinson TA; Pierce JE
J Biomed Mater Res; 1977 Jul; 11(4):471-81. PubMed ID: 873940
[TBL] [Abstract][Full Text] [Related]
3. Improved platelet economy using filler free silicone rubber in long term membrane lung perfusion.
Zapol WM; Bloom S; Carvalho A; Wonders T; Skoskiewicz M; Schneider R; Snider M
Trans Am Soc Artif Intern Organs; 1975; 21():587-92. PubMed ID: 167494
[No Abstract] [Full Text] [Related]
4. Superior blood compatibility of silicone rubber free of silica filler in the membrane lung.
Kolobow T; Stool EW; Weathersby PK; Pierce J; Hayano F; Suaudeau J
Trans Am Soc Artif Intern Organs; 1974; 20A():269-76. PubMed ID: 4450347
[No Abstract] [Full Text] [Related]
5. Effects of filler-free silicone rubber on platelets during bovine extracorporeal membrane oxygenation.
Yates WG; Schaap RN; Baumann GC
Trans Am Soc Artif Intern Organs; 1978; 24():644-9. PubMed ID: 716072
[No Abstract] [Full Text] [Related]
6. Platelet lifespan and gas exchange during perfusion with spiral coil membrane lungs coated with ethylcellulose perfluorobutyrate.
Bloom SR; Snider MT; Petersen R; Wonders TR; Zapol WM
Trans Am Soc Artif Intern Organs; 1976; 22():119-27. PubMed ID: 951833
[No Abstract] [Full Text] [Related]
7. Hematologic responses to prolonged extracorporeal circulation (ECC) with microporous membrane devices.
Bartlett RH; Fong SW; Woldanski C; Hung E; Styler D; MacArthur C
Trans Am Soc Artif Intern Organs; 1975; 21():250-7. PubMed ID: 1145997
[TBL] [Abstract][Full Text] [Related]
8. Platelet destruction during 24 hour membrane lung perfusion.
Bloom S; Zapol W; Wonders T; Berger S; Salzman E
Trans Am Soc Artif Intern Organs; 1974; 20A():299-305. PubMed ID: 4450351
[No Abstract] [Full Text] [Related]
9. Biocompatibility of standard and silica-free silicone rubber membrane oxygenators.
Fountain SW; Duffin J; Ward CA; Osada H; Martin BA; Cooper JD
Am J Physiol; 1979 Feb; 236(2):H371-5. PubMed ID: 420320
[TBL] [Abstract][Full Text] [Related]
10. The toroidal membrane oxygenator: design, performance, and prolonged bypass testing of a clinical model.
Bartlett RH; Drinker PA; Burns NE; Fong SW; Hyans T
Trans Am Soc Artif Intern Organs; 1972; 18(0):369-74. PubMed ID: 4679890
[No Abstract] [Full Text] [Related]
11. Dispersion-casting thin and ultrathin fabric-reinforced silicone rubber membrane for use in the membrane lung.
Kolobow T; Hayano F; Weathersby PK
Med Instrum; 1975; 9(3):124-8. PubMed ID: 1128319
[TBL] [Abstract][Full Text] [Related]
12. Nature of thrombus in a hollow fiber oxygenator.
Schneider MD
Am J Vet Res; 1973 Feb; 34(2):151-68. PubMed ID: 4568247
[No Abstract] [Full Text] [Related]
13. Fate of indium 111-labeled platelets during cardiopulmonary bypass performed with membrane and bubble oxygenators.
Peterson KA; Dewanjee MK; Kaye MP
J Thorac Cardiovasc Surg; 1982 Jul; 84(1):39-43. PubMed ID: 7087539
[TBL] [Abstract][Full Text] [Related]
14. Platelet function during cardiac operation: comparison of membrane and bubble oxygenators.
Edmunds LH; Ellison N; Colman RW; Niewiarowski S; Rao AK; Addonizio VP; Stephenson LW; Edie RN
J Thorac Cardiovasc Surg; 1982 Jun; 83(6):805-12. PubMed ID: 7087507
[TBL] [Abstract][Full Text] [Related]
15. Measurement of emboli in extracorporeal perfusion systems.
Dutton RC; Edmunds LH
J Thorac Cardiovasc Surg; 1973 Apr; 65(4):523-30. PubMed ID: 4697441
[No Abstract] [Full Text] [Related]
16. The effect of sulfinpyrazone on platelet and pulmonary responses to onset of membrane oxygenator perfusion.
Birek A; Duffin J; Glynn MF; Cooper JD
Trans Am Soc Artif Intern Organs; 1976; 22():94-101. PubMed ID: 951897
[No Abstract] [Full Text] [Related]
17. Pathophysiology and mechanics of membrane lung performance deterioration.
Ward BD; Hood AG; Hershgold EJ
Trans Am Soc Artif Intern Organs; 1975; 21():206-15. PubMed ID: 1145993
[No Abstract] [Full Text] [Related]
18. Iloprost (ZK36374), a stable analogue of prostacyclin, preserves platelets during simulated extracorporeal circulation.
Addonizio VP; Fisher CA; Jenkin BK; Strauss JF; Musial JF; Edmunds LH
J Thorac Cardiovasc Surg; 1985 Jun; 89(6):926-33. PubMed ID: 2582210
[TBL] [Abstract][Full Text] [Related]
19. Improving the efficiency of a tubular membrane oxygenator.
Zingg W; Matthews EI
Med Prog Technol; 1976; 4(3):139-45. PubMed ID: 1018702
[TBL] [Abstract][Full Text] [Related]
20. A new gas permeable membrane for blood oxygenators.
Eiseman B; Birnbaum D; Leonard R; Martinez FJ
Surg Gynecol Obstet; 1972 Nov; 135(5):732-6. PubMed ID: 5084244
[No Abstract] [Full Text] [Related]
[Next] [New Search]