These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

108 related articles for article (PubMed ID: 951850)

  • 1. Automatic control of the artificial heart.
    Pierce WS; Landis D; O'Bannon W; Donachy JH; White W; Phillips W; Brighton JA
    Trans Am Soc Artif Intern Organs; 1976; 22():347-56. PubMed ID: 951850
    [TBL] [Abstract][Full Text] [Related]  

  • 2. On the control of artificial hearts.
    Crosby MJ
    Adv Biomed Eng Med Phys; 1970; 3():89-114. PubMed ID: 5527800
    [No Abstract]   [Full Text] [Related]  

  • 3. Continuous flow total artificial heart: modeling and feedback control in a mock circulatory system.
    Khalil HA; Kerr DT; Franchek MA; Metcalfe RW; Benkowski RJ; Cohn WE; Tuzun E; Radovancevic B; Frazier OH; Kadipasaoglu KA
    ASAIO J; 2008; 54(3):249-55. PubMed ID: 18496274
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Development of a microcontroller-based automatic control system for the electrohydraulic total artificial heart.
    Kim HC; Khanwilkar PS; Bearnson GB; Olsen DB
    IEEE Trans Biomed Eng; 1997 Jan; 44(1):77-89. PubMed ID: 9214786
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Vascular tone estimation in patients implanted with the AbioCor implantable replacement heart.
    Kung RT; Zhang H
    Artif Organs; 2004 Jun; 28(6):543-8. PubMed ID: 15153146
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Design and haemodynamic evaluation of the ellipsoid heart for total heart replacement].
    Unger F
    Wien Klin Wochenschr Suppl; 1977; 65():1-17. PubMed ID: 264718
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effects of a total artificial heart right stroke volume limiter on left-right hemodynamic balance.
    Fukamachi K; Massiello AL; Kiraly RJ; Chen JF; Himley S; Davies C; Fukumura F; Muramoto K; Olsen E; Golding LA
    ASAIO J; 1993; 39(3):M410-4. PubMed ID: 8268568
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In vitro and in vivo evaluation of a left-right balancing capacity of an interatrial shunt in an electrohydraulic total artificial heart system.
    Tatsumi E; Nakamura M; Masuzawa T; Taenaka Y; Sohn YS; Nishimura T; Nakata M; Nakatani T; Ohno T; Endo S; Takiura K; Takewa Y; Kakuta Y; Takano H
    ASAIO J; 1997; 43(5):M619-25. PubMed ID: 9360119
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An atrial hydraulic shunt in a total artificial heart. A balance mechanism for the bronchial shunt.
    Kung RT; Yu LS; Ochs B; Parnis S; Frazier OH
    ASAIO J; 1993; 39(3):M213-7. PubMed ID: 8268531
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Adaptive full-ejection point detection for automatic control of the electrohydraulic total artificial heart.
    Kim HC; Khanwilkar PS; Long JW; Olsen DB
    ASAIO J; 1993; 39(4):899-903. PubMed ID: 8123924
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Left ventricular assist device weaning: hemodynamic response and relationship to stroke volume and rate reduction protocols.
    Slaughter MS; Sobieski MA; Koenig SC; Pappas PS; Tatooles AJ; Silver MA
    ASAIO J; 2006; 52(3):228-33. PubMed ID: 16760709
    [TBL] [Abstract][Full Text] [Related]  

  • 12. In vivo long-term evaluation of the Utah electrohydraulic total artificial heart.
    Tatsumi E; Khanwilkar PS; Rowles JR; Chiang BY; Burns GL; Long JW; Hansen AC; Holfert JW; Bearnson GB; Crump KR
    ASAIO J; 1993; 39(3):M373-80. PubMed ID: 8268562
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Determining arterial pressure, left atrial pressure and cardiac output from the left pneumatic drive line of the total artificial heart.
    Rosenberg G; Landis DL; Phillips WM; Stallsmith J; Pierce WS
    Trans Am Soc Artif Intern Organs; 1978; 24():341-4. PubMed ID: 362675
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Use of left atrial pressure as a control parameter for total left heart bypass.
    Klopp EH; Jacobs LA; Hoffman BF; Seamone W; Gott VL
    Trans Am Soc Artif Intern Organs; 1969; 15():391-9. PubMed ID: 5791415
    [No Abstract]   [Full Text] [Related]  

  • 15. Fuzzy logic automatic control of the Phoenix-7 total artificial heart.
    Hsu CH
    J Artif Organs; 2004; 7(2):69-76. PubMed ID: 15309673
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The effect of left ventricular function and drive pressures on the filling and ejection of a pulsatile pediatric ventricular assist device in an acute animal model.
    Lukic B; Zapanta CM; Khalapyan T; Connell J; Pae WE; Myers JL; Wilson RP; Undar A; Rosenberg G; Weiss WJ
    ASAIO J; 2007; 53(3):379-84. PubMed ID: 17515733
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Cardiac output regulation in the moving actuator total artificial heart without a compliance chamber.
    Kim HC; Min BG
    ASAIO J; 1992; 38(4):846-50. PubMed ID: 1450484
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Use of M-mode and Doppler echocardiography to investigate the cardiotoxicity of minoxidil in beagle dogs.
    Hanton G; Gautier M; Bonnet P
    Arch Toxicol; 2004 Jan; 78(1):40-8. PubMed ID: 12937890
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Pressure-flow studies in man: effect of atrial systole on left ventricular function.
    Ruskin J; McHale PA; Harley A; Greenfield JC
    J Clin Invest; 1970 Mar; 49(3):472-8. PubMed ID: 5415675
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Control system implementation in the air-driven artificial heart.
    Brickman AD; Landis DL; O'Bannon W; Mortimer VD; Nisley E; Pierce WE
    Trans Am Soc Artif Intern Organs; 1974; 20 B():680-4. PubMed ID: 4450316
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.