These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
47 related articles for article (PubMed ID: 951866)
1. New methods for the in vitro investigations of the flow patterns in artificial hearts. Affeld K; Zartnack F; Mohnhaupt R; Bücherl ES Trans Am Soc Artif Intern Organs; 1976; 22():460-7. PubMed ID: 951866 [TBL] [Abstract][Full Text] [Related]
2. Numerical dye washout method as a tool for characterizing the heart valve flow: study of three standard mechanical heart valves. Goubergrits L; Kertzscher U; Affeld K; Petz C; Stalling D; Hege HC ASAIO J; 2008; 54(1):50-7. PubMed ID: 18204316 [TBL] [Abstract][Full Text] [Related]
3. Characterization of an artificial valve flow using the numerical dye washout visualization technique: application to the monoleaflet valve with purged flow. Goubergrits L; Timmel T; Affeld K; Petz C; Stalling D; Hege HC Artif Organs; 2006 Aug; 30(8):642-50. PubMed ID: 16911322 [TBL] [Abstract][Full Text] [Related]
4. The artificial heart - progress, problems, and further development. Bücherl ES Med Prog Technol; 1976 Jul; 4(1-2):61-70. PubMed ID: 995073 [TBL] [Abstract][Full Text] [Related]
5. Velocity measurements and flow patterns within the hinge region of a Medtronic Parallel bileaflet mechanical valve with clear housing. Ellis JT; Healy TM; Fontaine AA; Saxena R; Yoganathan AP J Heart Valve Dis; 1996 Nov; 5(6):591-9. PubMed ID: 8953436 [TBL] [Abstract][Full Text] [Related]
6. In vitro characterization of aortic retrograde and antegrade flow from pulsatile and non-pulsatile ventricular assist devices. DiGiorgi PL; Smith DL; Naka Y; Oz MC J Heart Lung Transplant; 2004 Feb; 23(2):186-92. PubMed ID: 14761766 [TBL] [Abstract][Full Text] [Related]
7. In vivo evaluations of a new thromboresistant polyurethane for artificial heart blood pumps. Farrar DJ; Litwak P; Lawson JH; Ward RS; White KA; Robinson AJ; Rodvien R; Hill JD J Thorac Cardiovasc Surg; 1988 Feb; 95(2):191-200. PubMed ID: 3339889 [TBL] [Abstract][Full Text] [Related]
8. The use of enzyme activated milk for in vitro simulation of prosthetic valve thrombosis. Keggen LA; Black MM; Lawford PV; Hose DR; Strachan JR J Heart Valve Dis; 1996 Jan; 5(1):74-83. PubMed ID: 8834729 [TBL] [Abstract][Full Text] [Related]
9. An in vitro investigation of the retrograde flow fields of two bileaflet mechanical heart valves. Ellis JT; Healy TM; Fontaine AA; Weston MW; Jarret CA; Saxena R; Yoganathan AP J Heart Valve Dis; 1996 Nov; 5(6):600-6. PubMed ID: 8953437 [TBL] [Abstract][Full Text] [Related]