These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

215 related articles for article (PubMed ID: 9529932)

  • 41. Class I and Class II restorations of resin composite: an FE analysis of the influence of modulus of elasticity on stresses generated by occlusal loading.
    Asmussen E; Peutzfeldt A
    Dent Mater; 2008 May; 24(5):600-5. PubMed ID: 17767951
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Shear versus micro-shear bond strength test: a finite element stress analysis.
    Placido E; Meira JB; Lima RG; Muench A; de Souza RM; Ballester RY
    Dent Mater; 2007 Sep; 23(9):1086-92. PubMed ID: 17123595
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Contribution of loading conditions and material properties to stress shielding near the tibial component of total knee replacements.
    Au AG; James Raso V; Liggins AB; Amirfazli A
    J Biomech; 2007; 40(6):1410-6. PubMed ID: 16846605
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Optimization of the bearing surface geometry of total knees.
    Sathasivam S; Walker PS
    J Biomech; 1994 Mar; 27(3):255-64. PubMed ID: 8051186
    [TBL] [Abstract][Full Text] [Related]  

  • 45. The influence of design, materials and kinematics on the in vitro wear of total knee replacements.
    McEwen HM; Barnett PI; Bell CJ; Farrar R; Auger DD; Stone MH; Fisher J
    J Biomech; 2005 Feb; 38(2):357-65. PubMed ID: 15598464
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Stresses in polyethylene components of contemporary total knee replacements.
    Bartel DL; Rawlinson JJ; Burstein AH; Ranawat CS; Flynn WF
    Clin Orthop Relat Res; 1995 Aug; (317):76-82. PubMed ID: 7671500
    [TBL] [Abstract][Full Text] [Related]  

  • 47. The effect of cartilage deformation on the laxity of the knee joint.
    Huss RA; Holstein H; O'Connor JJ
    Proc Inst Mech Eng H; 1999; 213(1):19-32. PubMed ID: 10087901
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Modeling axi-symmetrical joint contact with biphasic cartilage layers--an asymptotic solution.
    Wu JZ; Herzog W; Ronsky J
    J Biomech; 1996 Oct; 29(10):1263-81. PubMed ID: 8884472
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Contact stress at the anterior aspect of the tibial post in posterior-stabilized total knee replacement.
    Hamai S; Miura H; Matsuda S; Shimoto T; Higaki H; Iwamoto Y
    J Bone Joint Surg Am; 2010 Jul; 92(8):1765-73. PubMed ID: 20660240
    [TBL] [Abstract][Full Text] [Related]  

  • 50. High-flexion TKA designs: what are their in vivo contact mechanics?
    Sharma A; Komistek RD; Scuderi GR; Cates HE
    Clin Orthop Relat Res; 2007 Nov; 464():117-26. PubMed ID: 17975375
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Biphasic surface amorphous layer lubrication of articular cartilage.
    Graindorge S; Ferrandez W; Jin Z; Ingham E; Grant C; Twigg P; Fisher J
    Med Eng Phys; 2005 Dec; 27(10):836-44. PubMed ID: 16046176
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Influence of the shape of the layers in photo-cured dental restorations on the shrinkage stress peaks-FEM study.
    Kowalczyk P
    Dent Mater; 2009 Dec; 25(12):e83-91. PubMed ID: 19786300
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Three-dimensional finite element analysis of strength and adhesion of composite resin versus ceramic inlays in molars.
    Dejak B; Mlotkowski A
    J Prosthet Dent; 2008 Feb; 99(2):131-40. PubMed ID: 18262014
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Prediction of scratch resistance of cobalt chromium alloy bearing surface, articulating against ultra-high molecular weight polyethylene, due to third-body wear particles.
    Mirghany M; Jin ZM
    Proc Inst Mech Eng H; 2004; 218(1):41-50. PubMed ID: 14982345
    [TBL] [Abstract][Full Text] [Related]  

  • 55. The influence of elastic modulus mismatch between tooth and post and core restorations on root fracture.
    Ona M; Wakabayashi N; Yamazaki T; Takaichi A; Igarashi Y
    Int Endod J; 2013 Jan; 46(1):47-52. PubMed ID: 22775227
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Friction and lubrication in cushion form bearings for artificial hip joints.
    Auger DD; Dowson D; Fisher J; Jin ZM
    Proc Inst Mech Eng H; 1993; 207(1):25-33. PubMed ID: 8363695
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Influence of material heterogeneity on the mechanical response of articulated cartilages in a knee joint.
    Raju V; Koorata PK
    Proc Inst Mech Eng H; 2022 Sep; 236(9):1340-1348. PubMed ID: 35938648
    [TBL] [Abstract][Full Text] [Related]  

  • 58. The dominance of cyclic sliding in producing wear in total knee replacements.
    Blunn GW; Walker PS; Joshi A; Hardinge K
    Clin Orthop Relat Res; 1991 Dec; (273):253-60. PubMed ID: 1959278
    [TBL] [Abstract][Full Text] [Related]  

  • 59. A modified elastic foundation contact model for application in 3D models of the prosthetic knee.
    Pérez-González A; Fenollosa-Esteve C; Sancho-Bru JL; Sánchez-Marín FT; Vergara M; Rodríguez-Cervantes PJ
    Med Eng Phys; 2008 Apr; 30(3):387-98. PubMed ID: 17513163
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Tensile properties of human knee joint cartilage: I. Influence of ionic conditions, weight bearing, and fibrillation on the tensile modulus.
    Akizuki S; Mow VC; Müller F; Pita JC; Howell DS; Manicourt DH
    J Orthop Res; 1986; 4(4):379-92. PubMed ID: 3783297
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.