These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 9531696)

  • 1. [The intraoperative measured stimulation impedance of pacemaker electrodes is not a predictor for their longevity].
    Schuchert A; Schmidt W; Jakob M; Jung W; Karmann W; Kreuzer J; Staedt U; Stertmann WA; Treese N; Meinertz T
    Z Kardiol; 1998 Jan; 87(1):22-6. PubMed ID: 9531696
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Low stimulation impedance in pacemaker patients with cardiac diseases. The Thera Pacemaker Study Group].
    Schuchert A; van Langen H; Michels K; Meinertz T
    Dtsch Med Wochenschr; 1996 Aug; 121(34-35):1046-9. PubMed ID: 8829905
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of electrical characteristics between a steroid-eluting single-pass VDD lead and a standard steroid-eluting ventricular lead. Thera Pacemaker Study Group.
    Schuchert A; Van Langen H; Michels K; Meinertz T
    Pacing Clin Electrophysiol; 1997 Jul; 20(7):1787-9. PubMed ID: 9249832
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Steroid eluting high impedance pacing leads decrease short and long-term current drain: results from a multicenter clinical trial. CapSure Z investigators.
    Ellenbogen KA; Wood MA; Gilligan DM; Zmijewski M; Mans D
    Pacing Clin Electrophysiol; 1999 Jan; 22(1 Pt 1):39-48. PubMed ID: 9990599
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A randomized study on the effects of pacemaker programming to a lower output on projected pulse generator longevity.
    Schuchert A; Meinertz T;
    Pacing Clin Electrophysiol; 2001 Aug; 24(8 Pt 1):1234-9. PubMed ID: 11523609
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The influence of high versus normal impedance ventricular leads on pacemaker generator longevity.
    Berger T; Roithinger FX; Antretter H; Hangler H; Pachinger O; Hintringer F
    Pacing Clin Electrophysiol; 2003 Nov; 26(11):2116-20. PubMed ID: 14622313
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Long-term follow-up of pacemakers with an Autocapture pacing system.
    Erdinler I; Akyol A; Okmen E; Oguz E; Gurkan K; Ulufer T
    Jpn Heart J; 2002 Nov; 43(6):631-41. PubMed ID: 12558127
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Dual chamber pacing with a single-lead DDD pacing system.
    Naegeli B; Straumann E; Gerber A; Schuiki E; Kunz M; Niederhäuser U; Bertel O
    Pacing Clin Electrophysiol; 1999 Jul; 22(7):1013-9. PubMed ID: 10456629
    [TBL] [Abstract][Full Text] [Related]  

  • 9. VDD(R) pacing: short- and long-term stability of atrial sensing with a single lead system.
    Naegeli B; Osswald S; Pfisterer M; Burkart F
    Pacing Clin Electrophysiol; 1996 Apr; 19(4 Pt 1):455-64. PubMed ID: 8848393
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Predictive value of impedance of leadless pacemaker during implantation on trend changes of pacing threshold].
    Liu ZJ; Wu ZH; Xiao YC; Ma YX; Li XP; Yang H; Tu T; Zhou SH; Liu QM
    Zhonghua Xin Xue Guan Bing Za Zhi; 2022 Feb; 50(2):150-153. PubMed ID: 35172459
    [No Abstract]   [Full Text] [Related]  

  • 11. Long-term results of high vs. normal impedance ventricular leads on actual (Real-Life) pacemaker generator longevity.
    Etsadashvili K; Hintringer F; Stühlinger M; Dichtl W; Spuller K; Antretter H; Hangler H; Pachinger O; Roithinger FX; Berger T
    Europace; 2009 Feb; 11(2):200-5. PubMed ID: 19056744
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Neonates and infants requiring life-long cardiac pacing: How reliable are epicardial leads through childhood?
    Stanner C; Horndasch M; Vitanova K; Strbad M; Ono M; Hessling G; Lange R; Cleuziou J
    Int J Cardiol; 2019 Dec; 297():43-48. PubMed ID: 31630820
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effects of local steroid elution on chronic pacing threshold and impedance of endocardial pacemaker leads.
    Schuchert A; Kuck KH
    Cardiology; 1993; 83(4):240-3. PubMed ID: 8281540
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Chronic steroid-eluting lead performance: a comparison of atrial and ventricular pacing.
    Hua W; Mond HG; Strathmore N
    Pacing Clin Electrophysiol; 1997 Jan; 20(1 Pt 1):17-24. PubMed ID: 9121966
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [The effect of a lower stimulation frequency on the AV synchronicity of VDD pacemakers].
    Schuchert A; Schmidt W; Jakob M; Jung W; Karmann W; Kreuzer J; Staedt U; Stertmann WA; Treese N; Meinertz T
    Dtsch Med Wochenschr; 1997 Oct; 122(43):1303-7. PubMed ID: 9410693
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A fractally coated, 1.3 mm2 high impedance pacing electrode.
    Fröhlig G; Bolz A; Ströbel J; Rutz M; Lawall P; Schwerdt H; Schaldach M; Schieffer H
    Pacing Clin Electrophysiol; 1998 Jun; 21(6):1239-46. PubMed ID: 9633066
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Activated pyrolytic carbon tip pacing leads: an alternative to steroid-eluting pacing leads?
    Masini M; Lazzari M; Lorenzoni R; Domicelli AM; Micheletti A; Dianda R; Masini G
    Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 2):1832-5. PubMed ID: 8945051
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Initial experience with a co-radial bipolar pacing lead.
    Tang C; Yeung-Lai-Wah JA; Qi A; Mills P; Clark J; Tyers F
    Pacing Clin Electrophysiol; 1997 Jul; 20(7):1800-7. PubMed ID: 9249835
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of mid-term clinical experience with steroid-eluting active and passive fixation ventricular electrodes in children.
    Ceviz N; Celiker A; Küçükosmanoğlu O; Alehan D; Kiliç A; Uner A; Ozme S
    Pacing Clin Electrophysiol; 2000 Aug; 23(8):1245-9. PubMed ID: 10962746
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Five-year follow-up of a bipolar steroid-eluting ventricular pacing lead.
    Schwaab B; Fröhlig G; Berg M; Schwerdt H; Schieffer H
    Pacing Clin Electrophysiol; 1999 Aug; 22(8):1226-8. PubMed ID: 10461300
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.