These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

113 related articles for article (PubMed ID: 9534696)

  • 1. The magic angle phenomenon in tendons: effect of varying the MR echo time.
    Peh WC; Chan JH
    Br J Radiol; 1998 Jan; 71(841):31-6. PubMed ID: 9534696
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Manifestation of magic angle phenomenon: comparative study on effects of varying echo time and tendon orientation among various MR sequences.
    Li T; Mirowitz SA
    Magn Reson Imaging; 2003 Sep; 21(7):741-4. PubMed ID: 14559338
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of tendon orientation on MR imaging signal intensity: a manifestation of the "magic angle" phenomenon.
    Erickson SJ; Cox IH; Hyde JS; Carrera GF; Strandt JA; Estkowski LD
    Radiology; 1991 Nov; 181(2):389-92. PubMed ID: 1924777
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The effect of using shorter echo times in MR imaging of knee menisci: a study using a porcine model.
    Peh WC; Chan JH; Shek TW; Wong JW
    AJR Am J Roentgenol; 1999 Feb; 172(2):485-8. PubMed ID: 9930808
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Orientational analysis of the Achilles tendon and enthesis using an ultrashort echo time spectroscopic imaging sequence.
    Du J; Chiang AJ; Chung CB; Statum S; Znamirowski R; Takahashi A; Bydder GM
    Magn Reson Imaging; 2010 Feb; 28(2):178-84. PubMed ID: 19695811
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The influence of flip angle on the magic angle effect.
    Zurlo JV; Blacksin MF; Karimi S
    Skeletal Radiol; 2000 Oct; 29(10):593-6. PubMed ID: 11127683
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Magic angle effect in magnetic resonance imaging of the Achilles tendon and enthesis.
    Du J; Pak BC; Znamirowski R; Statum S; Takahashi A; Chung CB; Bydder GM
    Magn Reson Imaging; 2009 May; 27(4):557-64. PubMed ID: 19022600
    [TBL] [Abstract][Full Text] [Related]  

  • 8. High-resolution MR imaging of the asymptomatic Achilles tendon: new observations.
    Soila K; Karjalainen PT; Aronen HJ; Pihlajamäki HK; Tirman PJ
    AJR Am J Roentgenol; 1999 Aug; 173(2):323-8. PubMed ID: 10430128
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Determination of T1 relaxation time of normal equine tendons using magic angle magnetic resonance imaging.
    Spriet M; Wisner ER; Anthenill LA; Buonocore MH
    Vet Radiol Ultrasound; 2011; 52(2):149-53. PubMed ID: 21388465
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of deep digital flexor tendon orientation on magnetic resonance imaging signal intensity in isolated equine limbs-the magic angle effect.
    Busoni V; Snaps F
    Vet Radiol Ultrasound; 2002; 43(5):428-30. PubMed ID: 12375776
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Increased signal in the normal supraspinatus tendon on MR imaging: diagnostic pitfall caused by the magic-angle effect.
    Timins ME; Erickson SJ; Estkowski LD; Carrera GF; Komorowski RA
    AJR Am J Roentgenol; 1995 Jul; 165(1):109-14. PubMed ID: 7785568
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Cardiac MRI: comparison between single-shot fast spin echo and conventional spin echo sequences in the morphological evaluation of the ventricles.
    Erriquez D; Di Cesare E; Barile A; Gallucci M; Splendiani A; Masciocchi C
    Radiol Med; 2002; 103(1-2):34-44. PubMed ID: 11859299
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Quantitative characterization of the Achilles tendon in cadaveric specimens: T1 and T2* measurements using ultrashort-TE MRI at 3 T.
    Filho GH; Du J; Pak BC; Statum S; Znamorowski R; Haghighi P; Bydder G; Chung CB
    AJR Am J Roentgenol; 2009 Mar; 192(3):W117-24. PubMed ID: 19234239
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Fat-suppressed spoiled GRASS imaging of knee hyaline cartilage: technique optimization and comparison with conventional MR imaging.
    Disler DG; Peters TL; Muscoreil SJ; Ratner LM; Wagle WA; Cousins JP; Rifkin MD
    AJR Am J Roentgenol; 1994 Oct; 163(4):887-92. PubMed ID: 8092029
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Magic angle magnetic resonance imaging of diode laser induced and naturally occurring lesions in equine tendons.
    Spriet M; Murphy B; Vallance SA; Vidal MA; Whitcomb MB; Wisner ER
    Vet Radiol Ultrasound; 2012; 53(4):394-401. PubMed ID: 22548673
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ultrashort TE T1ρ magic angle imaging.
    Du J; Statum S; Znamirowski R; Bydder GM; Chung CB
    Magn Reson Med; 2013 Mar; 69(3):682-7. PubMed ID: 22539354
    [TBL] [Abstract][Full Text] [Related]  

  • 17. MR imaging of the lungs: value of short TE spin-echo pulse sequences.
    Mayo JR; MacKay A; Müller NL
    AJR Am J Roentgenol; 1992 Nov; 159(5):951-6. PubMed ID: 1414805
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The AAPM/RSNA physics tutorial for residents. Contrast mechanisms in spin-echo MR imaging.
    Plewes DB
    Radiographics; 1994 Nov; 14(6):1389-404; quiz 1405-6. PubMed ID: 7855348
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The magic angle effect in musculoskeletal MR imaging.
    Hayes CW; Parellada JA
    Top Magn Reson Imaging; 1996 Feb; 8(1):51-6. PubMed ID: 8820094
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Adapted techniques for clinical MR imaging of tendons.
    Schick F; Dammann F; Lutz O; Claussen CD
    MAGMA; 1995 Jul; 3(2):103-7. PubMed ID: 7496885
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.