These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

140 related articles for article (PubMed ID: 9543421)

  • 41. In vivo proton MR three-dimensional T1rho mapping of human articular cartilage: initial experience.
    Regatte RR; Akella SV; Borthakur A; Kneeland JB; Reddy R
    Radiology; 2003 Oct; 229(1):269-74. PubMed ID: 14519880
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Rotating-frame intermolecular double-quantum spin-lattice relaxation T1rho, DQC-weighted magnetic resonance imaging.
    Zheng B; Hwang DW; Chen Z; Hwang LP
    Magn Reson Med; 2005 Apr; 53(4):930-6. PubMed ID: 15799056
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Proton-selective 17O-1H distance measurements in fast magic-angle-spinning solid-state NMR spectroscopy for the determination of hydrogen bond lengths.
    Brinkmann A; Kentgens AP
    J Am Chem Soc; 2006 Nov; 128(46):14758-9. PubMed ID: 17105257
    [TBL] [Abstract][Full Text] [Related]  

  • 44. T1rho MRI contrast in the human brain: modulation of the longitudinal rotating frame relaxation shutter-speed during an adiabatic RF pulse.
    Michaeli S; Sorce DJ; Springer CS; Ugurbil K; Garwood M
    J Magn Reson; 2006 Jul; 181(1):135-47. PubMed ID: 16675277
    [TBL] [Abstract][Full Text] [Related]  

  • 45. T1rho dispersion of rat tissues in vitro.
    Koskinen SK; Virta AM; Niemi PT; Kajander SA; Komu ME
    Magn Reson Imaging; 1999 Sep; 17(7):1043-7. PubMed ID: 10463655
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Balanced spin-lock preparation for B
    Gram M; Seethaler M; Gensler D; Oberberger J; Jakob PM; Nordbeck P
    Magn Reson Med; 2021 May; 85(5):2771-2780. PubMed ID: 33166009
    [TBL] [Abstract][Full Text] [Related]  

  • 47. T
    Okuaki T; Takayama Y; Nishie A; Ogino T; Obara M; Honda H; Miyati T; Van Cauteren M
    Magn Reson Imaging; 2017 Jul; 40():17-23. PubMed ID: 28363761
    [TBL] [Abstract][Full Text] [Related]  

  • 48. New insights into rotating frame relaxation at high field.
    Spear JT; Gore JC
    NMR Biomed; 2016 Sep; 29(9):1258-73. PubMed ID: 26866422
    [TBL] [Abstract][Full Text] [Related]  

  • 49. T1rho-relaxation in articular cartilage: effects of enzymatic degradation.
    Duvvuri U; Reddy R; Patel SD; Kaufman JH; Kneeland JB; Leigh JS
    Magn Reson Med; 1997 Dec; 38(6):863-7. PubMed ID: 9402184
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Proteoglycan-induced changes in T1rho-relaxation of articular cartilage at 4T.
    Akella SV; Regatte RR; Gougoutas AJ; Borthakur A; Shapiro EM; Kneeland JB; Leigh JS; Reddy R
    Magn Reson Med; 2001 Sep; 46(3):419-23. PubMed ID: 11550230
    [TBL] [Abstract][Full Text] [Related]  

  • 51. T1rho of protein solutions at very low fields: dependence on molecular weight, concentration, and structure.
    Virta A; Komu M; Kormano M
    Magn Reson Med; 1997 Jan; 37(1):53-7. PubMed ID: 8978632
    [TBL] [Abstract][Full Text] [Related]  

  • 52. MRI Measures of Murine Liver Fibrosis.
    Lindquist DM; Fugate EM; Wang J; Sharma A; Gandhi CR; Dillman JR
    J Magn Reson Imaging; 2021 Sep; 54(3):739-749. PubMed ID: 33738856
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Local motions in poly(ethylene-co-norbornene) studied by (1)H NMR relaxometry.
    Makrocka-Rydzyk M; Woźniak-Braszak A; Jurga K; Jurga S
    Solid State Nucl Magn Reson; 2015 Oct; 71():67-72. PubMed ID: 26344135
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Sensitivity enhancement and heteronuclear distance measurements in biological 17O solid-state NMR.
    Brinkmann A; Kentgens AP
    J Phys Chem B; 2006 Aug; 110(32):16089-101. PubMed ID: 16898766
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Adiabatically prepared spin-lock approach for T1ρ-based dynamic glucose enhanced MRI at ultrahigh fields.
    Schuenke P; Koehler C; Korzowski A; Windschuh J; Bachert P; Ladd ME; Mundiyanapurath S; Paech D; Bickelhaupt S; Bonekamp D; Schlemmer HP; Radbruch A; Zaiss M
    Magn Reson Med; 2017 Jul; 78(1):215-225. PubMed ID: 27521026
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Proton spin-lock ratio imaging for quantitation of glycosaminoglycans in articular cartilage.
    Regatte RR; Akella SV; Borthakur A; Reddy R
    J Magn Reson Imaging; 2003 Jan; 17(1):114-21. PubMed ID: 12500280
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Proton longitudinal NMR relaxation of poly(p-phenylene sulfide) in the laboratory and the rotating frames reference.
    Jurga J; Woźniak-Braszak A; Fojud Z; Jurga K
    Solid State Nucl Magn Reson; 2004 Jan; 25(1-3):47-52. PubMed ID: 14698384
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Method for reduced SAR T1rho-weighted MRI.
    Wheaton AJ; Borthakur A; Corbo M; Charagundla SR; Reddy R
    Magn Reson Med; 2004 Jun; 51(6):1096-102. PubMed ID: 15170827
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Determination of T1rho values for head and neck tissues at 0.1 T: a comparison to T1 and T2 relaxation times.
    Markkola AT; Aronen HJ; Ramadan UA; Halavaara JT; Tanttu JI; Sepponen RE
    Magn Reson Imaging; 1998 May; 16(4):377-83. PubMed ID: 9665548
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Near-resonance spin-lock contrast.
    Moran PR; Hamilton CA
    Magn Reson Imaging; 1995; 13(6):837-46. PubMed ID: 8544655
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.