These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
259 related articles for article (PubMed ID: 9546473)
1. Quantitative comparison of wear debris from UHMWPE that has and has not been sterilised by gamma irradiation. Besong AA; Tipper JL; Ingham E; Stone MH; Wroblewski BM; Fisher J J Bone Joint Surg Br; 1998 Mar; 80(2):340-4. PubMed ID: 9546473 [TBL] [Abstract][Full Text] [Related]
2. A study of the combined effects of shelf ageing following irradiation in air and counterface roughness on the wear of UHMWPE. Besong AA; Hailey JL; Ingham E; Stone M; Wroblewski BM; Fisher J Biomed Mater Eng; 1997; 7(1):59-65. PubMed ID: 9171903 [TBL] [Abstract][Full Text] [Related]
3. The influence of inert packaging on the shelf ageing of gamma-irradiation sterilised ultra-high molecular weight polyethylene. Lu S; Orr JF; Buchanan FJ Biomaterials; 2003 Jan; 24(1):139-45. PubMed ID: 12417187 [TBL] [Abstract][Full Text] [Related]
4. Comparative wear and wear debris under three different counterface conditions of crosslinked and non-crosslinked ultra high molecular weight polyethylene. Endo MM; Barbour PS; Barton DC; Fisher J; Tipper JL; Ingham E; Stone MH Biomed Mater Eng; 2001; 11(1):23-35. PubMed ID: 11281576 [TBL] [Abstract][Full Text] [Related]
5. Effect of sterilization method and other modifications on the wear resistance of acetabular cups made of ultra-high molecular weight polyethylene. A hip-simulator study. McKellop H; Shen FW; Lu B; Campbell P; Salovey R J Bone Joint Surg Am; 2000 Dec; 82(12):1708-25. PubMed ID: 11130644 [TBL] [Abstract][Full Text] [Related]
6. Wear of retrieved UHMWPE hip liners. Lee KY; Kim SY; Shin D; Lee S; Kim S Yonsei Med J; 2004 Apr; 45(2):293-9. PubMed ID: 15119002 [TBL] [Abstract][Full Text] [Related]
7. Tribological behavior of artificial hip joint under the effects of magnetic field in dry and lubricated sliding. Zaki M; Aljinaidi A; Hamed M Biomed Mater Eng; 2003; 13(3):205-21. PubMed ID: 12883170 [TBL] [Abstract][Full Text] [Related]
8. The influence of molecular weight, crosslinking and counterface roughness on TNF-alpha production by macrophages in response to ultra high molecular weight polyethylene particles. Ingram JH; Stone M; Fisher J; Ingham E Biomaterials; 2004 Aug; 25(17):3511-22. PubMed ID: 15020125 [TBL] [Abstract][Full Text] [Related]
9. Wear of polyethylene in artificial hip joints: superolateral wear of the acetabulum. Fisher J J Bone Joint Surg Br; 1998 Mar; 80(2):190-1. PubMed ID: 9546441 [No Abstract] [Full Text] [Related]
10. [Current knowledge on the effect of technology and sterilization on the structure, properties and longevity of UHMWPE in total joint replacement]. Pokorný D; Šlouf M; Fulín P Acta Chir Orthop Traumatol Cech; 2012; 79(3):213-21. PubMed ID: 22840952 [TBL] [Abstract][Full Text] [Related]
11. Wear products of total hip arthroplasty: The case of polyethylene. Massin P; Achour S Morphologie; 2017 Mar; 101(332):1-8. PubMed ID: 27426252 [TBL] [Abstract][Full Text] [Related]
12. The performance of gamma- and EtO-sterilised UHMWPE acetabular cups tested under severe simulator conditions. Part 2: wear particle characteristics with isolation protocols. Affatato S; Bersaglia G; Emiliani D; Foltran I; Taddei P; Reggiani M; Ferrieri P; Toni A Biomaterials; 2003 Oct; 24(22):4045-55. PubMed ID: 12834600 [TBL] [Abstract][Full Text] [Related]
13. [Effect of sterilisation with formaldehyde, gamma irradiation and ethylene oxide on the properties of polyethylene joint replacement components]. Fulín P; Pokorný D; Slouf M; Vacková T; Dybal J; Sosna A Acta Chir Orthop Traumatol Cech; 2014; 81(1):33-9. PubMed ID: 24755055 [TBL] [Abstract][Full Text] [Related]
14. A comparison of the wear and physical properties of silane cross-linked polyethylene and ultra-high molecular weight polyethylene. Sakoda H; Voice AM; McEwen HM; Isaac GH; Hardaker C; Wroblewski BM; Fisher J J Arthroplasty; 2001 Dec; 16(8):1018-23. PubMed ID: 11740757 [TBL] [Abstract][Full Text] [Related]
15. The wear of ultra-high molecular weight polyethylene sliding on metallic and ceramic counterfaces representative of current femoral surfaces in joint replacement. Lancaster JG; Dowson D; Isaac GH; Fisher J Proc Inst Mech Eng H; 1997; 211(1):17-24. PubMed ID: 9141887 [TBL] [Abstract][Full Text] [Related]
16. Effects of the sterilisation method on the wear of UHMWPE acetabular cups tested in a hip joint simulator. Affatato S; Bordini B; Fagnano C; Taddei P; Tinti A; Toni A Biomaterials; 2002 Mar; 23(6):1439-46. PubMed ID: 11829439 [TBL] [Abstract][Full Text] [Related]
17. Comparison of wear, wear debris and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prostheses. Endo M; Tipper JL; Barton DC; Stone MH; Ingham E; Fisher J Proc Inst Mech Eng H; 2002; 216(2):111-22. PubMed ID: 12022418 [TBL] [Abstract][Full Text] [Related]
18. [Improve wear resistance of UHMWPE by O+ ion implanted]. Xiong D Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2003 Dec; 20(4):583-5, 596. PubMed ID: 14716850 [TBL] [Abstract][Full Text] [Related]
19. The effect of real-time aging on the oxidation and wear of highly cross-linked UHMWPE acetabular liners. Wannomae KK; Christensen SD; Freiberg AA; Bhattacharyya S; Harris WH; Muratoglu OK Biomaterials; 2006 Mar; 27(9):1980-7. PubMed ID: 16271756 [TBL] [Abstract][Full Text] [Related]
20. Design and wear testing of a temporomandibular joint prosthesis articulation. van Loon JP; Verkerke GJ; de Vries MP; de Bont LG J Dent Res; 2000 Feb; 79(2):715-21. PubMed ID: 10728972 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]