These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
207 related articles for article (PubMed ID: 9549691)
1. Dose from syringe procedures during technetium-99m radiopharmaceutical preparation. Prussin SG; Theofanous G; Casey D; Kim A J Nucl Med Technol; 1998 Mar; 26(1):32-7. PubMed ID: 9549691 [TBL] [Abstract][Full Text] [Related]
2. Adsorption of (99m)Tc-radiopharmaceuticals onto injection vials and syringes. Mushtaq A; Ur Rehman T; Safdar Mansur M; Jehangir M J Nucl Med Technol; 2008 Jun; 36(2):91-4. PubMed ID: 18483140 [TBL] [Abstract][Full Text] [Related]
3. A simple and effective technique to reduce staff exposure during the preparation of radiopharmaceuticals. Tsopelas C; Collins PJ; Blefari C J Nucl Med Technol; 2003 Mar; 31(1):37-40. PubMed ID: 12624127 [TBL] [Abstract][Full Text] [Related]
4. Stability of stabilized 99mTc-D,L-HMPAO stored in vials and syringes. Del Carmen Plancha-Mansanet M; Caballero-Calabuig E; Félix-Fontestad J; Reyes-Ojeda MD; Sopena-Novales P; Abreu-Sánchez P; Del Carmen Cano-Terol M; Sopena-Monforte R J Nucl Med Technol; 2008 Dec; 36(4):213-6. PubMed ID: 19008289 [TBL] [Abstract][Full Text] [Related]
5. [Trial manufacture of a plunger shield for a disposable plastic syringe]. Murakami S; Emoto T; Mori H; Fujita K; Kubo N Nihon Hoshasen Gijutsu Gakkai Zasshi; 2008 Aug; 64(8):922-9. PubMed ID: 18772534 [TBL] [Abstract][Full Text] [Related]
6. Comparison of four 1-mL syringes for administering first-pass radionuclide angiography doses. McGough CG; Huang DC; Hung JC J Nucl Med Technol; 1999 Sep; 27(3):227-9. PubMed ID: 10512480 [TBL] [Abstract][Full Text] [Related]
7. Experimental verification of lung dose with radiochromic film: comparison with Monte Carlo simulations and commercially available treatment planning systems. Paelinck L; Reynaert N; Thierens H; De Neve W; De Wagter C Phys Med Biol; 2005 May; 50(9):2055-69. PubMed ID: 15843736 [TBL] [Abstract][Full Text] [Related]
8. Investigation using an advanced extremity gamma instrumentation system of options for shielding the hand during the preparation and injection of radiopharmaceuticals. Whitby M; Martin CJ J Radiol Prot; 2003 Mar; 23(1):79-96. PubMed ID: 12729420 [TBL] [Abstract][Full Text] [Related]
9. Task-specific monitoring of nuclear medicine technologists' radiation exposure. Smart R Radiat Prot Dosimetry; 2004; 109(3):201-9. PubMed ID: 15254324 [TBL] [Abstract][Full Text] [Related]
10. Adsorption of radiopharmaceuticals to syringes: setting up a reliable protocol for its assessment. Stopar TG; Socan A; Peitl PK Nucl Med Commun; 2007 Dec; 28(12):951-5. PubMed ID: 18090223 [TBL] [Abstract][Full Text] [Related]
11. Evaluation of the stability of (99m)Tc-ECD and stabilized (99m)Tc-HMPAO stored in syringes. Koslowsky IL; Brake SE; Bitner SJ J Nucl Med Technol; 2001 Dec; 29(4):197-200. PubMed ID: 11756532 [TBL] [Abstract][Full Text] [Related]
12. The relationship between elution time and eluate volume using the Ultra-TechneKow DTE technetium-99m generator. Hung JC; Mahoney DW; Huang DC; Wang A J Nucl Med Technol; 2000 Sep; 28(3):178-81. PubMed ID: 11001502 [TBL] [Abstract][Full Text] [Related]