These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
167 related articles for article (PubMed ID: 9550354)
41. Red-free light for measurement of intraocular pressure using Goldmann applanation tonometer without fluorescein. Ghoneim EM Eur J Ophthalmol; 2014; 24(1):84-7. PubMed ID: 23873489 [TBL] [Abstract][Full Text] [Related]
42. Contact-based stiffness sensing of human eye. Kurita Y; Kempf R; Iida Y; Okude J; Kaneko M; Mishima HK; Tsukamoto H; Sugimoto E; Katakura S; Kobayashi K; Kiuchi Y IEEE Trans Biomed Eng; 2008 Feb; 55(2 Pt 1):739-45. PubMed ID: 18270012 [TBL] [Abstract][Full Text] [Related]
43. Comparing applanation tonometry and rebound tonometry in glaucomatous and ocular hypertensive eyes. Marini M; Da Pozzo S; Accardo A; Canziani T Eur J Ophthalmol; 2011; 21(3):258-63. PubMed ID: 20890884 [TBL] [Abstract][Full Text] [Related]
44. Comparison of Intraocular Pressure Measurements Obtained by Rebound, Noncontact, and Goldmann Applanation Tonometry in Children. Feng CS; Jin KW; Yi K; Choi DG Am J Ophthalmol; 2015 Nov; 160(5):937-943.e1. PubMed ID: 26210864 [TBL] [Abstract][Full Text] [Related]
45. Accuracy of the new ICare rebound tonometer vs. other portable tonometers in healthy eyes. García-Resúa C; González-Meijome JM; Gilino J; Yebra-Pimentel E Optom Vis Sci; 2006 Feb; 83(2):102-7. PubMed ID: 16501412 [TBL] [Abstract][Full Text] [Related]
46. Rebound tonometer: ideal tonometer for measurement of accurate intraocular pressure. Suman S; Agrawal A; Pal VK; Pratap VB J Glaucoma; 2014 Dec; 23(9):633-7. PubMed ID: 23429611 [TBL] [Abstract][Full Text] [Related]
47. [Measurement of intraocular pressure using the Tono-Pen in comparison with Goldmann applanation tonometry - a clinical study in 100 eyes]. Deuter CM; Schlote T; Hahn GA; Bende T; Derse M Klin Monbl Augenheilkd; 2002 Mar; 219(3):138-42. PubMed ID: 11987041 [TBL] [Abstract][Full Text] [Related]
48. [Effects of central corneal thickness and corneal curvature on measurement of intraocular pressure with Goldmann applanation tonometer and non-contact tonometer]. Zhang Y; Zhao JL; Bian AL; Liu XL; Jin YM Zhonghua Yan Ke Za Zhi; 2009 Aug; 45(8):713-8. PubMed ID: 20021884 [TBL] [Abstract][Full Text] [Related]
49. A miniaturized applanation tonometer. Ma JG; Xu DZ IEEE Trans Biomed Eng; 1999 Aug; 46(8):947-50. PubMed ID: 10431459 [TBL] [Abstract][Full Text] [Related]
50. [Evaluation of accuracy of measuring intraocular pressure by handheld non-contact applanation tonometer]. Chen X; Peng D; Zhou W; Zhong Y Yan Ke Xue Bao; 1995 Jun; 11(2):86-8. PubMed ID: 9208659 [TBL] [Abstract][Full Text] [Related]
51. ProTon tonometer determination of intraocular pressure in patients with scarred corneas. Jain AK; Sukhija J; Gupta A Indian J Ophthalmol; 2006 Jun; 54(2):95-8. PubMed ID: 16770025 [TBL] [Abstract][Full Text] [Related]
52. Agreement of rebound tonometer in measuring intraocular pressure with three types of applanation tonometers. Nakamura M; Darhad U; Tatsumi Y; Fujioka M; Kusuhara A; Maeda H; Negi A Am J Ophthalmol; 2006 Aug; 142(2):332-4. PubMed ID: 16876523 [TBL] [Abstract][Full Text] [Related]
53. Evaluation of the pressure phosphene tonometer as a self-tonometer. Naruse S; Mori K; Kinoshita S Ophthalmic Physiol Opt; 2005 Sep; 25(5):421-8. PubMed ID: 16101948 [TBL] [Abstract][Full Text] [Related]
54. Intraocular pressure values obtained by ocular response analyzer, dynamic contour tonometry, and goldmann tonometry in keratokonic corneas. Bayer A; Sahin A; Hürmeriç V; Ozge G J Glaucoma; 2010; 19(8):540-5. PubMed ID: 20164793 [TBL] [Abstract][Full Text] [Related]
55. [A new site-independent tonometer (ProTon) in comparison with the Goldmann applanation tonometer]. Gräf M; Wassill H; Dick B Klin Monbl Augenheilkd; 1995 Apr; 206(4):255-61. PubMed ID: 7791286 [TBL] [Abstract][Full Text] [Related]
56. Comparison of Goldmann applanation and applanation resonance tonometry in a biomicroscope-based in vitro porcine eye model. Hallberg P; Santala K; Lindén C; Lindahl OA; Eklund A J Med Eng Technol; 2006; 30(6):345-52. PubMed ID: 17060162 [TBL] [Abstract][Full Text] [Related]
57. The induction/impact tonometer: a new instrument to measure intraocular pressure in the rat. Kontiola AI; Goldblum D; Mittag T; Danias J Exp Eye Res; 2001 Dec; 73(6):781-5. PubMed ID: 11846509 [TBL] [Abstract][Full Text] [Related]
58. Effect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer. Gunvant P; Baskaran M; Vijaya L; Joseph IS; Watkins RJ; Nallapothula M; Broadway DC; O'Leary DJ Br J Ophthalmol; 2004 Apr; 88(4):518-22. PubMed ID: 15031169 [TBL] [Abstract][Full Text] [Related]
59. The Proview phosphene tonometer fails to measure ocular pressure accurately in clinical practice. Alvarez TL; Gollance SA; Thomas GA; Greene RJ; Marchetto PM; Moore EJ; Realini T; Liebmann JM; Ritch R; Lama P; Fechtner RD Ophthalmology; 2004 Jun; 111(6):1077-85. PubMed ID: 15177956 [TBL] [Abstract][Full Text] [Related]
60. Corvis ST Tonometer for Measuring Postoperative IOP in LASIK Patients. Hong J; Yu Z; Jiang C; Zhou X; Liu Z; Sun X; Xu J Optom Vis Sci; 2015 May; 92(5):589-95. PubMed ID: 25871871 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]