BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

52 related articles for article (PubMed ID: 9551113)

  • 1. [Comparative findings of digital thoracic images and digital images of statistical phantoms as film copy, a radiological work station and a PC].
    Ricke J; Wolf M; Zielinski C; Hosten N; Liebig T; Amthauer H; Hänninen EL; Schumacher T; Stroszczynski C; Bergh B; Emmel D; Schauer W
    Rofo; 1998 Mar; 168(3):264-9. PubMed ID: 9551113
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [ROC analysis in post-processing of image data in digital thoracic radiography].
    Müller RD; Hirche H; Voss M; Buddenbrock B; John V; Gocke P
    Rofo; 1995 Feb; 162(2):163-9. PubMed ID: 7881085
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Contrast mapping and evaluation for electronic X-ray images on CRT display monitor.
    Suzuki J; Furukawa I; Ono S; Kitamura M; Ando Y
    IEEE Trans Med Imaging; 1997 Dec; 16(6):772-84. PubMed ID: 9533578
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Assessment and optimisation of the image quality of chest-radiography systems.
    Redlich U; Hoeschen C; Doehring W
    Radiat Prot Dosimetry; 2005; 114(1-3):264-8. PubMed ID: 15933119
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [A comparison of the monitor and alternator findings of digital thoracic images with the aid of a computer-supported procedure].
    Heckermann D; Fink U; Schätzl M; Fink B; Kenn W; Miller P; Pistitsch C; Herrmann K; Reiser M
    Rofo; 1998 Jul; 169(1):38-44. PubMed ID: 9711281
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Patient doses and image quality in digital chest radiology.
    Salát D; Nikodemová D
    Radiat Prot Dosimetry; 2008; 129(1-3):147-9. PubMed ID: 18321878
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Digital radiography of the thorax with selenium detector. Clinical results and optimization potential of the technique].
    Procacci C; Minniti S; Caumo F; Moore F; Ternullo S; Predicatori F; Locatelli F; Pistolesi GF
    Radiol Med; 1998 Nov; 96(5):446-53. PubMed ID: 10051867
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Optimisation of image plate radiography with respect to tube voltage.
    Tingberg A; Sjöström D
    Radiat Prot Dosimetry; 2005; 114(1-3):286-93. PubMed ID: 15933123
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Digital chest radiography with a large image intensifier. An ROC study with an anthropomorphic phantom.
    Månsson LG; Kheddache S; Börjesson J; Mattsson S; Schlossman D
    Eur J Radiol; 1989 Nov; 9(4):208-13. PubMed ID: 2591385
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Radiation exposure of children in pediatric radiology. Part 4: Entrance doses achieved during the X-ray examination of the chest].
    Seidenbusch MC; Schneider K
    Rofo; 2008 Dec; 180(12):1082-103. PubMed ID: 19009497
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Analysis of image quality in digital chest imaging.
    De Hauwere A; Bacher K; Smeets P; Verstraete K; Thierens H
    Radiat Prot Dosimetry; 2005; 117(1-3):174-7. PubMed ID: 16461499
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Digital images obtained with a digital camera are not associated with a loss of critical information--a preliminary study.
    Peretz B; Kaffe I; Amir E
    Br Dent J; 2009 Mar; 206(5):E9; discussion 268-9. PubMed ID: 19265830
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Digital selenium radiography: a comparison of the picture quality of thoracic images in normal and reduced image formats based on the structural anatomical details].
    Zähringer M; Krug B; Kamm KF; Jung G; Dölken W; Wassmer G; Lackner K
    Rofo; 1998 Jul; 169(1):33-7. PubMed ID: 9711280
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Evaluation of image quality of medical facsimile as a radiological image recording system].
    Takizawa M; Sone S; Kiyono K; Sakai F; Aoki J; Oguchi K; Serizawa S; Shibata A; Kawai T; Gomi K
    Nihon Igaku Hoshasen Gakkai Zasshi; 1996 May; 56(6):432-5. PubMed ID: 8710468
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Neonatal chest computed radiography: image processing and optimal image display.
    Don S; Whiting BR; Ellinwood JS; Foos DH; Kronemer KA; Kraus RA
    AJR Am J Roentgenol; 2007 Apr; 188(4):1138-44. PubMed ID: 17377059
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [The digital reprocessing of under- and overexposed x-ray films with a personal computer].
    Fuhrmann R; Diedrich P
    Fortschr Kieferorthop; 1993 Feb; 54(1):38-44. PubMed ID: 8454247
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Design of a PC controlled test device for the study of patient motion in X-ray radiology: first applications and results.
    Guibelalde E; Vañó E; Fernández JM; Molinero A; Alberdi J; Merillas A
    Br J Radiol; 1998 Nov; 71(851):1185-91. PubMed ID: 10434914
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Shortcomings of low-cost imaging systems for viewing computed radiographs.
    Ricke J; Hänninen EL; Zielinski C; Amthauer H; Stroszczynski C; Liebig T; Wolf M; Hosten N
    Comput Med Imaging Graph; 2000; 24(1):25-32. PubMed ID: 10739319
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The diagnostic performance of a PC-based teleradiology link.
    Calder LD; Maclean JR; Bayliss AP; Gilbert FJ; Grant AM
    Clin Radiol; 1999 Oct; 54(10):659-64. PubMed ID: 10541391
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Application of StatPhantom software for image quality evaluation.
    Davydenko G; Gurvich V; Smekhov M
    J Digit Imaging; 2002; 15 Suppl 1():219-20. PubMed ID: 12105733
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 3.