104 related articles for article (PubMed ID: 9551825)
1. Analysis of minocycline by high-performance liquid chromatography in tissue and serum.
Wrightson WR; Myers SR; Galandiuk S
J Chromatogr B Biomed Sci Appl; 1998 Mar; 706(2):358-61. PubMed ID: 9551825
[TBL] [Abstract][Full Text] [Related]
2. High-performance liquid chromatographic assay for minocycline in human plasma and parotid saliva.
Orti V; Audran M; Gibert P; Bougard G; Bressolle F
J Chromatogr B Biomed Sci Appl; 2000 Feb; 738(2):357-65. PubMed ID: 10718653
[TBL] [Abstract][Full Text] [Related]
3. Liquid chromatographic determination of minocycline in brain-to-plasma distribution studies in the rat.
Colovic M; Caccia S
J Chromatogr B Analyt Technol Biomed Life Sci; 2003 Jul; 791(1-2):337-43. PubMed ID: 12798193
[TBL] [Abstract][Full Text] [Related]
4. Robust and sensitive high-performance liquid chromatographic-UV detection technique for the determination of tigecycline in rabbit plasma.
Zorpas KM; Valsami GN; Vryonis EV; Skoutelis AT; Archontaki HA
J AOAC Int; 2011; 94(3):847-56. PubMed ID: 21797013
[TBL] [Abstract][Full Text] [Related]
5. Improved LC of minocycline drug substance.
Zawilla NH; Diana J; Hoogmartens J; Adams E
J Pharm Biomed Anal; 2006 Mar; 40(4):815-21. PubMed ID: 16242288
[TBL] [Abstract][Full Text] [Related]
6. Determination of minocycline in human plasma by high-performance liquid chromatography with UV detection after liquid-liquid extraction.
Mascher HJ
J Chromatogr A; 1998 Jul; 812(1-2):339-42. PubMed ID: 9691330
[TBL] [Abstract][Full Text] [Related]
7. Analysis of a second-generation tetracycline antibiotic minocycline in human plasma by LC-MS/MS.
Patel DS; Sharma N; Patel MC; Patel BN; Shrivastav PS; Sanyal M
Bioanalysis; 2011 Oct; 3(19):2177-94. PubMed ID: 21985413
[TBL] [Abstract][Full Text] [Related]
8. An automated analyzer for vancomycin in plasma samples by column-switching high-performance liquid chromatography with UV detection.
Saito M; Santa T; Tsunoda M; Hamamoto H; Usui N
Biomed Chromatogr; 2004 Nov; 18(9):735-8. PubMed ID: 15386581
[TBL] [Abstract][Full Text] [Related]
9. Simultaneous UHPLC-UV analysis of hydroxychloroquine, minocycline and doxycycline from serum samples for the therapeutic drug monitoring of Q fever and Whipple's disease.
Armstrong N; Richez M; Raoult D; Chabriere E
J Chromatogr B Analyt Technol Biomed Life Sci; 2017 Aug; 1060():166-172. PubMed ID: 28622620
[TBL] [Abstract][Full Text] [Related]
10. [Simultaneous determination of six antibiotics in disinfection products by high performance liquid chromatography tandem mass spectrometry].
Fu H; Hu X; Ding C; Lin S
Wei Sheng Yan Jiu; 2012 Mar; 41(2):282-6. PubMed ID: 22611942
[TBL] [Abstract][Full Text] [Related]
11. Macrolide and ketolide antibiotic separation by reversed phase high performance liquid chromatography.
Lingerfelt B; Champney WS
J Pharm Biomed Anal; 1999 Jul; 20(3):459-69. PubMed ID: 10701962
[TBL] [Abstract][Full Text] [Related]
12. [Determination of tetracyclines antibiotics by reversed-phase high performance liquid chromatography].
Wang L; Zhang XS; Xu ZX; Shao XG
Se Pu; 2002 Jan; 20(1):49-51. PubMed ID: 12541619
[TBL] [Abstract][Full Text] [Related]
13. A sensitive assay of amoxicillin in mouse serum and broncho-alveolar lavage fluid by liquid-liquid extraction and reversed-phase HPLC.
Du X; Li C; Sun HK; Nightingale CH; Nicolau DP
J Pharm Biomed Anal; 2005 Sep; 39(3-4):648-52. PubMed ID: 15935600
[TBL] [Abstract][Full Text] [Related]
14. Simple and rapid determination of nevirapine in human serum by reversed-phase high-performance liquid chromatography.
Lopez RM; Pou L; Gomez MR; Ruiz I; Monterde J
J Chromatogr B Biomed Sci Appl; 2001 Feb; 751(2):371-6. PubMed ID: 11236094
[TBL] [Abstract][Full Text] [Related]
15. Determination of meropenem levels in human serum by high-performance liquid chromatography with ultraviolet detection.
Roth T; Fiedler S; Mihai S; Parsch H
Biomed Chromatogr; 2017 May; 31(5):. PubMed ID: 27797104
[TBL] [Abstract][Full Text] [Related]
16. Quantitation of tigecycline, a novel glycylcycline [corrected] by liquid chromatography.
Li C; Sutherland CA; Nightingale CH; Nicolau DP
J Chromatogr B Analyt Technol Biomed Life Sci; 2004 Nov; 811(2):225-9. PubMed ID: 15522724
[TBL] [Abstract][Full Text] [Related]
17. Validated stability-indicating densitometric thin-layer chromatography: application to stress degradation studies of minocycline.
Jain N; Jain GK; Ahmad FJ; Khar RK
Anal Chim Acta; 2007 Sep; 599(2):302-9. PubMed ID: 17870294
[TBL] [Abstract][Full Text] [Related]
18. High-performance liquid chromatographic assay of a new HIV-1 protease inhibitor, LB71350, in the plasma of dogs.
Jeong YN; Seo MK; Choi YJ; Kim IC; Lee YH
J Chromatogr B Biomed Sci Appl; 1997 Dec; 703(1-2):284-8. PubMed ID: 9448089
[TBL] [Abstract][Full Text] [Related]
19. Determination of ng rivanol in human plasma by SPE-HPLC method.
Guo Z; Wei D; Gan N; Xie H; Yu X
J Chromatogr Sci; 2007 Jul; 45(6):325-9. PubMed ID: 17626720
[TBL] [Abstract][Full Text] [Related]
20. Determination of the new podophyllotoxin derivative NK 611 in plasma by high-performance liquid chromatography with ultraviolet detection.
Hüttmann A; Mross K; Hossfeld DK
J Chromatogr; 1993 Oct; 620(2):233-8. PubMed ID: 8300791
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]