These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 9561360)

  • 21. Pulsatile ocular blood flow in eyes with untreated choroidal melanoma.
    Yang YC; Kent D; Fenerty CH; Kosmin AS; Damato BE
    Eye (Lond); 1997; 11 ( Pt 3)():331-4. PubMed ID: 9373471
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Pulsatile ocular blood flow in primary open-angle glaucoma and ocular hypertension.
    Kerr J; Nelson P; O'Brien C
    Am J Ophthalmol; 2003 Dec; 136(6):1106-13. PubMed ID: 14644222
    [TBL] [Abstract][Full Text] [Related]  

  • 23. The ocular blood flow tonograph: a new instrument for the measurement of intraocular pressure in rabbits.
    Chidlow G; Nash MS; Crowhurst C; Bron AJ; Osborne NN
    Exp Eye Res; 1996 Oct; 63(4):463-9. PubMed ID: 8944553
    [TBL] [Abstract][Full Text] [Related]  

  • 24. The effect of systemic hypertension on pulsatile ocular blood flow in diabetic patients.
    Esgin H; Alimgil ML; Erda S
    Acta Ophthalmol Scand; 2001 Apr; 79(2):160-2. PubMed ID: 11284754
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Pulsatile ocular blood flow and intraocular pressure during retrobulbar injection of lignocaine: influence of additives.
    Hulbert MF; Yang YC; Pennefather PM; Moore JK
    J Glaucoma; 1998 Dec; 7(6):413-6. PubMed ID: 9871864
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Ocular pulse amplitude measurement using pascal dynamic contour tonometer in glaucoma patients.
    Katsimpris JM; Theoulakis PE; Papadopoulos GE; Katsimpris A; Lepidas J; Petropoulos IK
    Klin Monbl Augenheilkd; 2014 Apr; 231(4):363-7. PubMed ID: 24771168
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Repeatability of ocular blood flow pneumotonometry.
    Bhan A; Bhargava J; Vernon SA; Armstrong S; Bhan K; Tong L; Sung V
    Ophthalmology; 2003 Aug; 110(8):1551-4. PubMed ID: 12917171
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Dynamic contour tonometry: handheld versus slit-lamp-mounted.
    Knecht PB; Bosch MM; Menke MN; Bachmann LM; Funk J; Kaufmann C
    Ophthalmology; 2009 Aug; 116(8):1450-4. PubMed ID: 19500848
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Assessment of IcareONE rebound tonometer for self-measuring intraocular pressure.
    Sakamoto M; Kanamori A; Fujihara M; Yamada Y; Nakamura M; Negi A
    Acta Ophthalmol; 2014 May; 92(3):243-8. PubMed ID: 23586927
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Pulsatile ocular blood flow: relationship with flow velocities in vessels supplying the retina and choroid.
    Zion IB; Harris A; Siesky B; Shulman S; McCranor L; Garzozi HJ
    Br J Ophthalmol; 2007 Jul; 91(7):882-4. PubMed ID: 17576711
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Intraocular pressure measurement precision with the Goldmann applanation, dynamic contour, and ocular response analyzer tonometers.
    Kotecha A; White E; Schlottmann PG; Garway-Heath DF
    Ophthalmology; 2010 Apr; 117(4):730-7. PubMed ID: 20122737
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Intraocular pressure and ocular pulse amplitude using dynamic contour tonometry and contact lens tonometry.
    Hoffmann EM; Grus FH; Pfeiffer N
    BMC Ophthalmol; 2004 Mar; 4():4. PubMed ID: 15038831
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The Proview phosphene tonometer fails to measure ocular pressure accurately in clinical practice.
    Alvarez TL; Gollance SA; Thomas GA; Greene RJ; Marchetto PM; Moore EJ; Realini T; Liebmann JM; Ritch R; Lama P; Fechtner RD
    Ophthalmology; 2004 Jun; 111(6):1077-85. PubMed ID: 15177956
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Ocular Perfusion Pressure and Pulsatile Ocular Blood Flow in Normal and Systemic Hypertensive Patients.
    Kanadani FN; Figueiredo CR; Miranda RM; Cunha PL; M Kanadani TC; Dorairaj S
    J Curr Glaucoma Pract; 2015; 9(1):16-9. PubMed ID: 26997827
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Comparison of intraocular pressure measurement between rebound, non-contact and Goldmann applanation tonometry in treated glaucoma patients.
    Vincent SJ; Vincent RA; Shields D; Lee GA
    Clin Exp Ophthalmol; 2012; 40(4):e163-70. PubMed ID: 21883774
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Age-related ocular blood flow changes.
    Ravalico G; Toffoli G; Pastori G; Crocè M; Calderini S
    Invest Ophthalmol Vis Sci; 1996 Dec; 37(13):2645-50. PubMed ID: 8977478
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A comparison of intraocular pressure measurements with the XPERT noncontact tonometer and Goldmann applanation tonometry.
    Popovich KS; Shields MB
    J Glaucoma; 1997 Feb; 6(1):44-6. PubMed ID: 9075080
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Comparison of the new rebound tonometer with Goldmann applanation tonometer in a clinical setting.
    Kim KN; Jeoung JW; Park KH; Yang MK; Kim DM
    Acta Ophthalmol; 2013 Aug; 91(5):e392-6. PubMed ID: 23521889
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Effect of corneal thickness on intraocular pressure measurements with the pneumotonometer, Goldmann applanation tonometer, and Tono-Pen.
    Bhan A; Browning AC; Shah S; Hamilton R; Dave D; Dua HS
    Invest Ophthalmol Vis Sci; 2002 May; 43(5):1389-92. PubMed ID: 11980851
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Intraocular pressure measurements with the Proview self-tonometer in comparison of Goldmann applanation tonometry in healthy and glaucomatous eyes].
    Meyer MW; Yevelenko V; Hoy L; Meyer A; Erb C
    Klin Monbl Augenheilkd; 2006 Nov; 223(11):899-903. PubMed ID: 17131250
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.