These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
158 related articles for article (PubMed ID: 9563353)
1. On bracket slot height: a methodologic study. Meling TR; Odegaard J; Seqner D Am J Orthod Dentofacial Orthop; 1998 Apr; 113(4):387-93. PubMed ID: 9563353 [TBL] [Abstract][Full Text] [Related]
2. In vitro biomechanical analysis of torque capabilities of various 0.018″ lingual bracket-wire systems: total torque play and slot size. Daratsianos N; Bourauel C; Fimmers R; Jäger A; Schwestka-Polly R Eur J Orthod; 2016 Oct; 38(5):459-69. PubMed ID: 26518759 [TBL] [Abstract][Full Text] [Related]
3. Actual versus theoretical torsional play in conventional and self-ligating bracket systems. Dalstra M; Eriksen H; Bergamini C; Melsen B J Orthod; 2015 Jun; 42(2):103-13. PubMed ID: 25588827 [TBL] [Abstract][Full Text] [Related]
4. Dimensional variability of orthodontic slots and archwires: an analysis of torque expression and clinical implications. Tepedino M; Paiella G; Iancu Potrubacz M; Monaco A; Gatto R; Chimenti C Prog Orthod; 2020 Sep; 21(1):32. PubMed ID: 32924097 [TBL] [Abstract][Full Text] [Related]
5. Bracket slot and archwire dimensions: manufacturing precision and third order clearance. Joch A; Pichelmayer M; Weiland F J Orthod; 2010 Dec; 37(4):241-9. PubMed ID: 21186304 [TBL] [Abstract][Full Text] [Related]
6. Deformation and warping of the bracket slot in select self-ligating orthodontic brackets due to an applied third order torque. Major TW; Carey JP; Nobes DS; Heo G; Major PW J Orthod; 2012 Mar; 39(1):25-33. PubMed ID: 22433324 [TBL] [Abstract][Full Text] [Related]
7. Torque capabilities of self-ligating and conventional brackets under the effect of bracket width and free wire length. Huang Y; Keilig L; Rahimi A; Reimann S; Bourauel C Orthod Craniofac Res; 2012 Nov; 15(4):255-62. PubMed ID: 23020696 [TBL] [Abstract][Full Text] [Related]
8. Measurements of the torque moment in various archwire-bracket-ligation combinations. Hirai M; Nakajima A; Kawai N; Tanaka E; Igarashi Y; Sakaguchi M; Sameshima GT; Shimizu N Eur J Orthod; 2012 Jun; 34(3):374-80. PubMed ID: 21571875 [TBL] [Abstract][Full Text] [Related]
9. Comparative analysis of real and ideal wire-slot play in square and rectangular archwires. Lombardo L; Arreghini A; Bratti E; Mollica F; Spedicato G; Merlin M; Fortini A; Siciliani G Angle Orthod; 2015 Sep; 85(5):848-58. PubMed ID: 25405384 [TBL] [Abstract][Full Text] [Related]
10. Three-dimensional relationship between the critical contact angle and the torque angle. Kang BS; Baek SH; Mah J; Yang WS Am J Orthod Dentofacial Orthop; 2003 Jan; 123(1):64-73. PubMed ID: 12532065 [TBL] [Abstract][Full Text] [Related]
11. Variability of effective root torque as a function of edge bevel on orthodontic arch wires. Sebanc J; Brantley WA; Pincsak JJ; Conover JP Am J Orthod; 1984 Jul; 86(1):43-51. PubMed ID: 6588759 [TBL] [Abstract][Full Text] [Related]
12. Torque efficiency of square and rectangular archwires into 0.018 and 0.022 in. conventional brackets. Papageorgiou SN; Sifakakis I; Doulis I; Eliades T; Bourauel C Prog Orthod; 2016; 17():5. PubMed ID: 26780465 [TBL] [Abstract][Full Text] [Related]
13. Evaluation of friction during sliding tooth movement in various bracket-arch wire combinations. Loftus BP; Artun J; Nicholls JI; Alonzo TA; Stoner JA Am J Orthod Dentofacial Orthop; 1999 Sep; 116(3):336-45. PubMed ID: 10474108 [TBL] [Abstract][Full Text] [Related]
14. Third-order torque and self-ligating orthodontic bracket-type effects on sliding friction. Chung M; Nikolai RJ; Kim KB; Oliver DR Angle Orthod; 2009 May; 79(3):551-7. PubMed ID: 19413378 [TBL] [Abstract][Full Text] [Related]
15. Frictional resistances of different bracket-wire combinations. Kapur Wadhwa R; Kwon HK; Close JM Aust Orthod J; 2004 May; 20(1):25-30. PubMed ID: 15233584 [TBL] [Abstract][Full Text] [Related]
16. Torque transmission between square wire and bracket as a function of measurement, form and hardness parameters. Fischer-Brandies H; Orthuber W; Es-Souni M; Meyer S J Orofac Orthop; 2000; 61(4):258-65. PubMed ID: 10961051 [TBL] [Abstract][Full Text] [Related]
17. Comparison of load transmission and bracket deformation between titanium and stainless steel brackets. Kapur R; Sinha PK; Nanda RS Am J Orthod Dentofacial Orthop; 1999 Sep; 116(3):275-8. PubMed ID: 10474099 [TBL] [Abstract][Full Text] [Related]
18. Torque expression of self-ligating brackets compared with conventional metallic, ceramic, and plastic brackets. Morina E; Eliades T; Pandis N; Jäger A; Bourauel C Eur J Orthod; 2008 Jun; 30(3):233-8. PubMed ID: 18540011 [TBL] [Abstract][Full Text] [Related]
19. Torsional creep of polycarbonate orthodontic brackets. Alkire RG; Bagby MD; Gladwin MA; Kim H Dent Mater; 1997 Jan; 13(1):2-6. PubMed ID: 9467316 [TBL] [Abstract][Full Text] [Related]
20. The effect of buccal-lingual slot dimension size on third-order torque response. Romanyk DL; Au K; Isfeld D; Heo G; Major MP; Major PW Eur J Orthod; 2017 Apr; 39(2):209-214. PubMed ID: 27259532 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]