These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

166 related articles for article (PubMed ID: 9564553)

  • 1. Comparison between the CEDIA and EMIT II immunoassays for the determination of benzodiazepines.
    Way BA; Walton KG; Koenig JW; Eveland BJ; Scott MG
    Clin Chim Acta; 1998 Mar; 271(1):1-9. PubMed ID: 9564553
    [TBL] [Abstract][Full Text] [Related]  

  • 2. KIMS, CEDIA, and HS-CEDIA immunoassays are inadequately sensitive for detection of benzodiazepines in urine from patients treated for chronic pain.
    Darragh A; Snyder ML; Ptolemy AS; Melanson S
    Pain Physician; 2014; 17(4):359-66. PubMed ID: 25054395
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of the Microgenics CEDIA heroin metabolite (6-AM) and the Roche Abuscreen ONLINE opiate immunoassays for the detection of heroin use in forensic urine samples.
    Holler JM; Bosy TZ; Klette KL; Wiegand R; Jemionek J; Jacobs A
    J Anal Toxicol; 2004 Sep; 28(6):489-93. PubMed ID: 15516301
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of several immunoassays used in drugs of abuse screening: Assessment against gold standard methods and calculation of measurement uncertainty.
    Mina A
    J Pharmacol Toxicol Methods; 2020; 101():106649. PubMed ID: 31730939
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of different immunoassays and GC-MS screening of benzodiazepines in urine.
    Augsburger M; Rivier L; Mangin P
    J Pharm Biomed Anal; 1998 Dec; 18(4-5):681-7. PubMed ID: 9919969
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Drug screening in urine by cloned enzyme donor immunoassay (CEDIA) and kinetic interaction of microparticles in solution (KIMS): a comparative study.
    Schwettmann L; Külpmann WR; Vidal C
    Clin Chem Lab Med; 2006; 44(4):479-87. PubMed ID: 16599844
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Detectability of designer benzodiazepines in CEDIA, EMIT II Plus, HEIA, and KIMS II immunochemical screening assays.
    Pettersson Bergstrand M; Helander A; Hansson T; Beck O
    Drug Test Anal; 2017 Apr; 9(4):640-645. PubMed ID: 27366870
    [TBL] [Abstract][Full Text] [Related]  

  • 8. CEDIA for screening drugs of abuse in urine and the effect of adulterants.
    Wu AH; Forte E; Casella G; Sun K; Hemphill G; Foery R; Schanzenbach H
    J Forensic Sci; 1995 Jul; 40(4):614-8. PubMed ID: 7595298
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Identification of urinary benzodiazepines and their metabolites: comparison of automated HPLC and GC-MS after immunoassay screening of clinical specimens.
    Valentine JL; Middleton R; Sparks C
    J Anal Toxicol; 1996 Oct; 20(6):416-24. PubMed ID: 8889678
    [TBL] [Abstract][Full Text] [Related]  

  • 10. New fluorescence polarization immunoassays for analysis of barbiturates and benzodiazepines in serum and urine: performance characteristics.
    Schwenzer KS; Pearlman R; Tsilimidos M; Salamone SJ; Cannon RC; Wong SH; Gock SB; Jentzen JJ
    J Anal Toxicol; 2000; 24(8):726-32. PubMed ID: 11110029
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of assay methods for benzodiazepines in urine. A receptor assay, two immunoassays, and gas chromatography-mass spectrometry.
    Nishikawa T; Ohtani H; Herold DA; Fitzgerald RL
    Am J Clin Pathol; 1997 Mar; 107(3):345-52. PubMed ID: 9052386
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of the diagnostic performance of the Boehringer Mannheim CEDIA LSD assay.
    Verstraete AG; Steyaert S
    J Anal Toxicol; 1998; 22(7):601-4. PubMed ID: 9847012
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Improved CEDIA benzodiazepine assay eliminates sertraline crossreactivity.
    Fitzgerald RL; Herold DA
    J Anal Toxicol; 1997; 21(1):32-5. PubMed ID: 9013289
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of the usefulness of an oxycodone immunoassay in combination with a traditional opiate immunoassay for the screening of opiates in urine.
    Gingras M; Laberge MH; Lefebvre M
    J Anal Toxicol; 2010 Mar; 34(2):78-83. PubMed ID: 20223099
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Urine benzodiazepine screening using Roche Online KIMS immunoassay with beta-glucuronidase hydrolysis and confirmation by gas chromatography- mass spectrometry.
    Klette KL; Wiegand RF; Horn CK; Stout PR; Magluilo J
    J Anal Toxicol; 2005 Apr; 29(3):193-200. PubMed ID: 15842763
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Drug screening and confirmation by GC-MS: comparison of EMIT II and Online KIMS against 10 drugs between US and England laboratories.
    Lu NT; Taylor BG
    Forensic Sci Int; 2006 Mar; 157(2-3):106-16. PubMed ID: 15899564
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Optimization and validation of CEDIA drugs of abuse immunoassay tests in serum on Hitachi 912.
    Kirschbaum KM; Musshoff F; Schmithausen R; Stockhausen S; Madea B
    Forensic Sci Int; 2011 Oct; 212(1-3):252-5. PubMed ID: 21775079
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Therapeutic monitoring of benzodiazepines in the management of pain: current limitations of point of care immunoassays suggest testing by mass spectrometry to assure accuracy and improve patient safety.
    Mikel C; Pesce AJ; Rosenthal M; West C
    Clin Chim Acta; 2012 Aug; 413(15-16):1199-202. PubMed ID: 22484396
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Precision and comparability of Abuscreen OnLine assays for drugs of abuse screening in urine on Hitachi 917 with other immunochemical tests and with GC/MS.
    Boettcher M; Haenseler E; Hoke C; Nichols J; Raab D; Domke I
    Clin Lab; 2000; 46(1-2):49-52. PubMed ID: 10745981
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The online screening technique for urinary benzodiazepines: comparison with EMIT, FPIA, and GC-MS.
    Beck O; Lin Z; Brodin K; Borg S; Hjemdahl P
    J Anal Toxicol; 1997; 21(7):554-7. PubMed ID: 9399125
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.