BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

262 related articles for article (PubMed ID: 9566281)

  • 1. Blood glucose determinations in newborns: four instruments compared.
    Schlebusch H; Niesen M; Sorger M; Paffenholz I; Fahnenstich H
    Pediatr Pathol Lab Med; 1998; 18(1):41-8. PubMed ID: 9566281
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Evaluation of the quality of blood glucose meters using the HemoCue B glucose system].
    Lefèvre G; Girardot-Dubois S; Chevallier G; Cohen C; Couderc R; Etienne J
    Diabetes Metab; 1999 Sep; 25(4):350-5. PubMed ID: 10566127
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical utility of a bedside blood analyzer for measuring blood chemistry values in neonates.
    Alex CP; Manto JC; Garland JS
    J Perinatol; 1998; 18(1):45-8. PubMed ID: 9527944
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Performance characteristics of the HemoCue B-Glucose analyzer using whole-blood samples.
    Voss EM; Cembrowski GS
    Arch Pathol Lab Med; 1993 Jul; 117(7):711-3. PubMed ID: 8323435
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of "point of care" devices in the measurement of low blood glucose in neonatal practice.
    Ho HT; Yeung WK; Young BW
    Arch Dis Child Fetal Neonatal Ed; 2004 Jul; 89(4):F356-9. PubMed ID: 15210675
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Interinstitutional comparison of bedside blood glucose monitoring program characteristics, accuracy performance, and quality control documentation: a College of American Pathologists Q-Probes study of bedside blood glucose monitoring performed in 226 small hospitals.
    Novis DA; Jones BA
    Arch Pathol Lab Med; 1998 Jun; 122(6):495-502. PubMed ID: 9625416
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The Hemocue B glucose analyser and neonatal blood glucose monitoring.
    Zijlstra WG; Hart N; Baarsma R
    Ann Clin Biochem; 1998 Mar; 35 ( Pt 2)():330. PubMed ID: 9547915
    [No Abstract]   [Full Text] [Related]  

  • 8. [Is reliable blood glucose determination in the newborn infant possible with the small reflectance meter Reflolux S?].
    Schlebusch H; Niesen M; Paffenholz I
    Klin Padiatr; 1993; 205(2):111-5. PubMed ID: 8487477
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Accuracy of bedside glucose measurement from three glucometers in critically ill patients.
    Hoedemaekers CW; Klein Gunnewiek JM; Prinsen MA; Willems JL; Van der Hoeven JG
    Crit Care Med; 2008 Nov; 36(11):3062-6. PubMed ID: 18824915
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy and precision of the i-STAT portable clinical analyzer: an analytical point of view.
    Pidetcha P; Ornvichian S; Chalachiva S
    J Med Assoc Thai; 2000 Apr; 83(4):445-50. PubMed ID: 10808706
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The effects of precision, haematocrit, pH and oxygen tension on point-of-care glucose measurement in critically ill patients: a prospective study.
    Watkinson PJ; Barber VS; Amira E; James T; Taylor R; Young JD
    Ann Clin Biochem; 2012 Mar; 49(Pt 2):144-51. PubMed ID: 22349553
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Laboratory assessment of three glucometers.
    Ajala MO; Oladipo OO; Fasanmade O; Adewole TA
    Afr J Med Med Sci; 2003 Sep; 32(3):279-82. PubMed ID: 15030088
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [The influence of blood oxygen tension on the glucose level measured by a handy blood glucose analyzer (Toecho Super)].
    Takezaki T; Nakao M; Niinai H; Nakatani K; Kawaguchi R; Hanaki C; Nakao M
    Masui; 1994 Apr; 43(4):589-93. PubMed ID: 8189628
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Review article: glucose measurement in the operating room: more complicated than it seems.
    Rice MJ; Pitkin AD; Coursin DB
    Anesth Analg; 2010 Apr; 110(4):1056-65. PubMed ID: 20142354
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of the Glucometer Elite XL device for screening for neonatal hypoglycaemia.
    Michel A; Küster H; Krebs A; Kadow I; Paul W; Nauck M; Fusch C
    Eur J Pediatr; 2005 Nov; 164(11):660-4. PubMed ID: 16041524
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Plasma-equivalent glucose at the point-of-care: evaluation of Roche Accu-Chek Inform and Abbott Precision PCx glucose meters.
    Ghys T; Goedhuys W; Spincemaille K; Gorus F; Gerlo E
    Clin Chim Acta; 2007; 386(1-2):63-8. PubMed ID: 17727831
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Quality control of capillary blood measurements in clinical services: follow up by the biologist].
    Desjobert H; Durand G; Chérubin N; Le Moël G
    Diabetes Metab; 2001 Apr; 27(2 Pt 1):177-81. PubMed ID: 11353886
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The Hemocue B glucose analyser and neonatal blood glucose monitoring.
    Daae LN
    Ann Clin Biochem; 1998 Mar; 35 ( Pt 2)():331-2. PubMed ID: 9547917
    [No Abstract]   [Full Text] [Related]  

  • 19. Hematocrit correction does not improve glucose monitor accuracy in the assessment of neonatal hypoglycemia.
    Wang L; Sievenpiper JL; de Souza RJ; Thomaz M; Blatz S; Grey V; Fusch C; Balion C
    Clin Chem Lab Med; 2013 Aug; 51(8):1627-35. PubMed ID: 23420286
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Clinical utility and accuracy of a blood glucose meter for the detection of neonatal hypoglycemia.
    Hamid MH; Chishti AL; Maqbool S
    J Coll Physicians Surg Pak; 2004 Apr; 14(4):225-8. PubMed ID: 15228827
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.