These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 9569521)

  • 1. Evaluation of multifrequency bioimpedance spectroscopy for measurement of the extracellular water space in critically ill patients.
    Plank LD; Monk DN; Woollard GA; Hill GL
    Appl Radiat Isot; 1998; 49(5-6):481-3. PubMed ID: 9569521
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Role of bioimpedance spectroscopy in assessment of body water compartments in hemodialysis patients.
    Cox-Reijven PL; Kooman JP; Soeters PB; van der Sande FM; Leunissen KM
    Am J Kidney Dis; 2001 Oct; 38(4):832-8. PubMed ID: 11576887
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Bioimpedance and Fluid Status in Children and Adolescents Treated With Dialysis.
    Milani GP; Groothoff JW; Vianello FA; Fossali EF; Paglialonga F; Edefonti A; Agostoni C; Consonni D; van Harskamp D; van Goudoever JB; Schierbeek H; Oosterveld MJ
    Am J Kidney Dis; 2017 Mar; 69(3):428-435. PubMed ID: 28089477
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Multifrequency bioelectrical impedance estimates the distribution of body water.
    Cha K; Chertow GM; Gonzalez J; Lazarus JM; Wilmore DW
    J Appl Physiol (1985); 1995 Oct; 79(4):1316-9. PubMed ID: 8567578
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Human hydrometry: comparison of multifrequency bioelectrical impedance with 2H2O and bromine dilution.
    Ellis KJ; Wong WW
    J Appl Physiol (1985); 1998 Sep; 85(3):1056-62. PubMed ID: 9729583
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A critical evaluation of bioimpedance spectroscopy analysis in estimating body composition during GH treatment: comparison with bromide dilution and dual X-ray absorptiometry.
    Birzniece V; Khaw CH; Nelson AE; Meinhardt U; Ho KK
    Eur J Endocrinol; 2015 Jan; 172(1):21-8. PubMed ID: 25326135
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Using dilution techniques and multifrequency bioelectrical impedance to assess both total body water and extracellular water at baseline and during recombinant human growth hormone (GH) treatment in GH-deficient adults.
    Janssen YJ; Deurenberg P; Roelfsema F
    J Clin Endocrinol Metab; 1997 Oct; 82(10):3349-55. PubMed ID: 9329367
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Suitability of Bioelectrical Based Methods to Assess Water Compartments in Recreational and Elite Athletes.
    Matias CN; Júdice PB; Santos DA; Magalhães JP; Minderico CS; Fields DA; Sardinha LB; Silva AM
    J Am Coll Nutr; 2016 Jul; 35(5):413-21. PubMed ID: 26934568
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Multifrequency bioelectric impedance measurements for predicting body water compartments in duchenne muscular dystrophy.
    Bedogni G; Merlini L; Ballestrazzi A; Severi S; Battistini N
    Neuromuscul Disord; 1996 Jan; 6(1):55-60. PubMed ID: 8845719
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of multiple frequency bioelectrical impedance and Cole-Cole analysis for the assessment of body water volumes in healthy humans.
    Cornish BH; Ward LC; Thomas BJ; Jebb SA; Elia M
    Eur J Clin Nutr; 1996 Mar; 50(3):159-64. PubMed ID: 8654329
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Body composition in patients with an ileostomy and inflammatory bowel disease: validation of bio-electric impedance spectroscopy (BIS).
    Carlsson E; Bosaeus I; Nordgren S
    Eur J Clin Nutr; 2002 Jul; 56(7):680-6. PubMed ID: 12080410
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Deuterium and bromide dilution, and bioimpedance spectrometry independently show that growth hormone-deficient adults have an enlarged extracellular water compartment related to intracellular water.
    van Marken Lichtenbelt WD; Snel YE; Brummer RJ; Koppeschaar HP
    J Clin Endocrinol Metab; 1997 Mar; 82(3):907-11. PubMed ID: 9062505
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Assessment of total body water and its compartments in elite judo athletes: comparison of bioelectrical impedance spectroscopy with dilution techniques.
    Gonçalves EM; Matias CN; Santos DA; Sardinha LB; Silva AM
    J Sports Sci; 2015; 33(6):634-40. PubMed ID: 25278240
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Body fluid volumes measurements by impedance: A review of bioimpedance spectroscopy (BIS) and bioimpedance analysis (BIA) methods.
    Jaffrin MY; Morel H
    Med Eng Phys; 2008 Dec; 30(10):1257-69. PubMed ID: 18676172
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Segmental bioelectrical impedance analysis improves the prediction for extracellular water volume changes during abdominal surgery.
    Tatara T; Tsuzaki K
    Crit Care Med; 1998 Mar; 26(3):470-6. PubMed ID: 9504574
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Measurement of body composition changes during weight loss in obese men using multi-frequency bioelectrical impedance analysis and multi-compartment models.
    Johnstone AM; Faber P; Gibney ER; Lobley GE; Stubbs RJ; Siervo M
    Obes Res Clin Pract; 2014; 8(1):e46-54. PubMed ID: 24548576
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Multi-frequency bioelectrical impedance for assessing total body water and extracellular water in elderly subjects.
    Visser M; Deurenberg P; van Staveren WA
    Eur J Clin Nutr; 1995 Apr; 49(4):256-66. PubMed ID: 7796783
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Body water compartment measurements: a comparison of bioelectrical impedance analysis with tritium and sodium bromide dilution techniques.
    Simpson JA; Lobo DN; Anderson JA; Macdonald IA; Perkins AC; Neal KR; Allison SP; Rowlands BJ
    Clin Nutr; 2001 Aug; 20(4):339-43. PubMed ID: 11478832
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Measurement of body water by multifrequency bioelectrical impedance spectroscopy in a multiethnic pediatric population.
    Ellis KJ; Shypailo RJ; Wong WW
    Am J Clin Nutr; 1999 Nov; 70(5):847-53. PubMed ID: 10539745
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Predicting body cell mass with bioimpedance by using theoretical methods: a technological review.
    De Lorenzo A; Andreoli A; Matthie J; Withers P
    J Appl Physiol (1985); 1997 May; 82(5):1542-58. PubMed ID: 9134904
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.