These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

105 related articles for article (PubMed ID: 9569611)

  • 1. Microbial cell-based biosensor for sensing glucose, sucrose or lactose.
    Svitel J; Curilla O; Tkác J
    Biotechnol Appl Biochem; 1998 Apr; 27(2):153-8. PubMed ID: 9569611
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Enzymatic membranes for determination of some disaccharides by means of an oxygen electrode.
    Filipiak M; Fludra K; Gościmińska E
    Biosens Bioelectron; 1996; 11(4):355-64. PubMed ID: 8746183
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Development of biosensors for the simultaneous determination of sucrose and glucose, lactose and glucose, and starch and glucose.
    Watanabe E; Takagi M; Takei S; Hoshi M; Shu-Gui C
    Biotechnol Bioeng; 1991 Jun; 38(1):99-103. PubMed ID: 18600703
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Development of conductometric biosensor array for simultaneous determination of maltose, lactose, sucrose and glucose.
    Soldatkin OO; Peshkova VM; Saiapina OY; Kucherenko IS; Dudchenko OY; Melnyk VG; Vasylenko OD; Semenycheva LM; Soldatkin AP; Dzyadevych SV
    Talanta; 2013 Oct; 115():200-7. PubMed ID: 24054580
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Detection of ethanol in a two-component glucose/ethanol mixture using a nonselective microbial sensor and a glucose enzyme electrode.
    Reshetilov AN; Lobanov AV; Morozova NO; Gordon SH; Greene RV; Leathers TD
    Biosens Bioelectron; 1998 Oct; 13(7-8):787-93. PubMed ID: 9828373
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Measurement of glucose, sucrose and lactose in food samples with enzyme-immobilised packed-bed column reactors integrated to an amperometric enzyme electrode.
    Boyaci IH; Mutlu M
    Nahrung; 2002 Jun; 46(3):174-8. PubMed ID: 12108216
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Hybrid biosensor for the determination of lactose.
    Svorc J; Miertus S; Barlíková A
    Anal Chem; 1990 Aug; 62(15):1628-31. PubMed ID: 2205123
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Permeabilization of Kluyveromyces marxianus with mild detergent for whey lactose hydrolysis and augmentation of mixed culture.
    Yadav JS; Bezawada J; Yan S; Tyagi RD; Surampalli RY
    Appl Biochem Biotechnol; 2014 Mar; 172(6):3207-22. PubMed ID: 24500798
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Enhancement of operational stability of an enzyme biosensor for glucose and sucrose using protein based stabilizing agents.
    Gouda MD; Kumar MA; Thakur MS; Karanth NG
    Biosens Bioelectron; 2002 Jun; 17(6-7):503-7. PubMed ID: 11959471
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biosensor for determination of glucose and sucrose in fruit juices by flow injection analysis.
    Guémas Y; Boujtita M; el Murr N
    Appl Biochem Biotechnol; 2000; 89(2-3):171-81. PubMed ID: 11209461
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fabrication of sucrose biosensor based on single mode planar optical waveguide using co-immobilized plant invertase and GOD.
    Bagal DS; Vijayan A; Aiyer RC; Karekar RN; Karve MS
    Biosens Bioelectron; 2007 Jun; 22(12):3072-9. PubMed ID: 17314040
    [TBL] [Abstract][Full Text] [Related]  

  • 12. FET-microbial sensor for xylose detection based on Gluconobacter oxydans cells.
    Reshetilov AN; Donova MV; Dovbnya DV; Boronin AM; Leathers TD; Greene RV
    Biosens Bioelectron; 1996; 11(4):401-8. PubMed ID: 8746186
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Development of an integrated electrochemical biosensor for sucrose and its implementation in a continuous flow system for the simultaneous monitoring of sucrose, fructose and glucose.
    Vargas E; Gamella M; Campuzano S; Guzmán-Vázquez de Prada A; Ruiz MA; Reviejo AJ; Pingarrón JM
    Talanta; 2013 Feb; 105():93-100. PubMed ID: 23597994
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Enzyme-based sensor arrays for rapid characterization of complex disaccharide solutions.
    Curey TE; Salazar MA; Oliveira P; Javier J; Dennis PJ; Rao P; Shear JB
    Anal Biochem; 2002 Apr; 303(1):42-8. PubMed ID: 11906149
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Study on multiple-enzyme electrode for sucrose determination.
    Hu W; Zhang X; Zhang X; Hu S
    Chin J Biotechnol; 1991; 7(4):293-300. PubMed ID: 1824242
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Whole-cell Gluconobacter oxydans biosensor for 2-phenylethanol biooxidation monitoring.
    Schenkmayerová A; Bertóková A; Sefčovičová J; Stefuca V; Bučko M; Vikartovská A; Gemeiner P; Tkáč J; Katrlík J
    Anal Chim Acta; 2015 Jan; 854():140-4. PubMed ID: 25479877
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Whole cell immobilized amperometric biosensor based on Saccharomyces cerevisiae for selective determination of vitamin B1 (thiamine).
    Akyilmaz E; Yaşa I; Dinçkaya E
    Anal Biochem; 2006 Jul; 354(1):78-84. PubMed ID: 16701070
    [TBL] [Abstract][Full Text] [Related]  

  • 18. An integrated amperometric biosensor for the determination of lactose in milk and dairy products.
    Conzuelo F; Gamella M; Campuzano S; Ruiz MA; Reviejo AJ; Pingarrón JM
    J Agric Food Chem; 2010 Jun; 58(12):7141-8. PubMed ID: 20509693
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Invertase-nanogold clusters decorated plant membranes for fluorescence-based sucrose sensor.
    Bagal-Kestwal D; Kestwal RM; Chiang BH
    J Nanobiotechnology; 2015 Apr; 13():30. PubMed ID: 25886379
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Beta-galactosidase monitoring by a biosensor based on Clark electrode: its optimization, characterization and application.
    Sezgintürk MK; Dinçkaya E
    Biosens Bioelectron; 2008 Jul; 23(12):1799-804. PubMed ID: 18395435
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.