151 related articles for article (PubMed ID: 9571104)
1. Multilayer Gradient Coil Design.
Bowtell R; Robyr P
J Magn Reson; 1998 Apr; 131(2):286-94. PubMed ID: 9571104
[TBL] [Abstract][Full Text] [Related]
2. Actively shielded multi-layer gradient coil designs with improved cooling properties.
Leggett J; Crozier S; Bowtell RW
J Magn Reson; 2003 Dec; 165(2):196-207. PubMed ID: 14643701
[TBL] [Abstract][Full Text] [Related]
3. Hemispherical gradient coils for magnetic resonance imaging.
Green D; Leggett J; Bowtell R
Magn Reson Med; 2005 Sep; 54(3):656-68. PubMed ID: 16086303
[TBL] [Abstract][Full Text] [Related]
4. A cone-shaped gradient coil design for high-resolution MRI head imaging.
Tang F; Hao J; Freschi F; Niu C; Repetto M; Liu F; Crozier S
Phys Med Biol; 2019 Apr; 64(8):085003. PubMed ID: 30780134
[TBL] [Abstract][Full Text] [Related]
5. Numerical Design of High-Efficiency Whole-Body Gradient Coils With a Hybrid Cylindrical-Planar Structure.
Chaoqun Niu ; Qiuliang Wang ; Yang Hu ; Yaohui Wang ; Fangfang Tang ; Feng Liu ; Crozier S
IEEE Trans Biomed Eng; 2019 Jun; 66(6):1628-1636. PubMed ID: 30346278
[TBL] [Abstract][Full Text] [Related]
6. Spiral Gradient Coil Design for Use in Cylindrical MRI Systems.
Wang Y; Xin X; Liu F; Crozier S
IEEE Trans Biomed Eng; 2018 Apr; 65(4):911-920. PubMed ID: 28715323
[TBL] [Abstract][Full Text] [Related]
7. Systematic Dimensional Analysis of the Scaling Relationship for Gradient and Shim Coil Design Parameters.
Lee SK; Bernstein MA
Magn Reson Med; 2022 Oct; 88(4):1901-1911. PubMed ID: 35666832
[TBL] [Abstract][Full Text] [Related]
8. Minimax current density gradient coils: analysis of coil performance and heating.
Poole MS; While PT; Lopez HS; Crozier S
Magn Reson Med; 2012 Aug; 68(2):639-48. PubMed ID: 22807068
[TBL] [Abstract][Full Text] [Related]
9. Analytic approach to the design of transverse gradient coils with co-axial return paths.
Bowtell R; Peters A
Magn Reson Med; 1999 Mar; 41(3):600-8. PubMed ID: 10204885
[TBL] [Abstract][Full Text] [Related]
10. Highly efficient head-only magnetic field insert gradient coil for achieving simultaneous high gradient amplitude and slew rate at 3.0T (MAGNUS) for brain microstructure imaging.
Foo TKF; Tan ET; Vermilyea ME; Hua Y; Fiveland EW; Piel JE; Park K; Ricci J; Thompson PS; Graziani D; Conte G; Kagan A; Bai Y; Vasil C; Tarasek M; Yeo DTB; Snell F; Lee D; Dean A; DeMarco JK; Shih RY; Hood MN; Chae H; Ho VB
Magn Reson Med; 2020 Jun; 83(6):2356-2369. PubMed ID: 31763726
[TBL] [Abstract][Full Text] [Related]
11. Strong gradients for spatially resolved diffusion measurements.
Snaar JE; Robyr P; Bowtell R
Magn Reson Imaging; 1998; 16(5-6):587-91. PubMed ID: 9803915
[TBL] [Abstract][Full Text] [Related]
12. Asymmetric gradient coil design for use in a short, open bore magnetic resonance imaging scanner.
Wang Y; Liu F; Li Y; Tang F; Crozier S
J Magn Reson; 2016 Aug; 269():203-212. PubMed ID: 27372211
[TBL] [Abstract][Full Text] [Related]
13. A spiral, bi-planar gradient coil design for open magnetic resonance imaging.
Zhang P; Shi Y; Wang W; Wang Y
Technol Health Care; 2018; 26(1):119-132. PubMed ID: 29254119
[TBL] [Abstract][Full Text] [Related]
14. Fast optimization of a biplanar gradient coil set.
Tomasi D; Caparelli EC; Panepucci H; Foerster B
J Magn Reson; 1999 Oct; 140(2):325-39. PubMed ID: 10497040
[TBL] [Abstract][Full Text] [Related]
15. Optimization of torque-balanced asymmetric head gradient coils.
Alsop DC; Connick TJ
Magn Reson Med; 1996 Jun; 35(6):875-86. PubMed ID: 8744016
[TBL] [Abstract][Full Text] [Related]
16. Design and fabrication of a three-axis multilayer gradient coil for magnetic resonance microscopy of mice.
Chronik B; Alejski A; Rutt BK
MAGMA; 2000 Jun; 10(2):131-46. PubMed ID: 10873203
[TBL] [Abstract][Full Text] [Related]
17. Analytic calculations of the E-fields induced by time-varying magnetic fields generated by cylindrical gradient coils.
Bowtell R; Bowley RM
Magn Reson Med; 2000 Nov; 44(5):782-90. PubMed ID: 11064413
[TBL] [Abstract][Full Text] [Related]
18. Peripheral nerve stimulation informed design of a high-performance asymmetric head gradient coil.
Davids M; Dietz P; Ruyters G; Roesler M; Klein V; Guérin B; Feinberg DA; Wald LL
Magn Reson Med; 2023 Aug; 90(2):784-801. PubMed ID: 37052387
[TBL] [Abstract][Full Text] [Related]
19. An improved equivalent magnetization current method applied to the design of local breast gradient coils.
Lopez HS; Poole M; Crozier S
J Magn Reson; 2009 Jul; 199(1):48-55. PubMed ID: 19375368
[TBL] [Abstract][Full Text] [Related]
20. A power efficient actively shielded two-channel transverse MRI gradient coil numerical design.
Kassahun HB; Alsharafi SS; Badawi AM; El-Sharkawy AM
J Magn Reson; 2023 Sep; 354():107526. PubMed ID: 37536091
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]