These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

152 related articles for article (PubMed ID: 9571488)

  • 1. Biomechanical properties of absorbable implants in finger fractures.
    Fitoussi F; Lu W; Ip WY; Chow SP
    J Hand Surg Br; 1998 Feb; 23(1):79-83. PubMed ID: 9571488
    [TBL] [Abstract][Full Text] [Related]  

  • 2. External fixation for comminuted phalangeal fractures. A biomechanical cadaver study.
    Fitoussi F; Ip WY; Chow SP
    J Hand Surg Br; 1996 Dec; 21(6):760-4. PubMed ID: 8982919
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Self-reinforced bioabsorbable versus metallic fixation systems for metacarpal and phalangeal fractures: a biomechanical study.
    Waris E; Ashammakhi N; Raatikainen T; Törmälä P; Santavirta S; Konttinen YT
    J Hand Surg Am; 2002 Sep; 27(5):902-9. PubMed ID: 12239683
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The stability of internal fixation in the proximal phalanx.
    Black DM; Mann RJ; Constine RM; Daniels AU
    J Hand Surg Am; 1986 Sep; 11(5):672-7. PubMed ID: 3760493
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A self-locking pin for fixation of small bones and phalanges: a preliminary report.
    Rosenberg L; Rotgoltz J
    Ann Plast Surg; 1986 Jan; 16(1):60-7. PubMed ID: 3273012
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Mini and micro plating of phalangeal and metacarpal fractures: a biomechanical study.
    Prevel CD; Eppley BL; Jackson JR; Moore K; McCarty M; Sood R; Wood R [corrected to Sood R]
    J Hand Surg Am; 1995 Jan; 20(1):44-9. PubMed ID: 7722264
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparative mechanical properties of various Kirschner wire configurations in transverse and oblique phalangeal fractures.
    Viegas SF; Ferren EL; Self J; Tencer AF
    J Hand Surg Am; 1988 Mar; 13(2):246-53. PubMed ID: 3351253
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Biomechanical and functional testing of plate fixation devices for proximal phalangeal fractures.
    Nunley JA; Kloen P
    J Hand Surg Am; 1991 Nov; 16(6):991-8. PubMed ID: 1748770
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Intramedullary fixation by resorbable rods in a comminuted phalangeal fracture model. A biomechanical study.
    Roure P; Ip WY; Lu W; Chow SP; Gogolewski S
    J Hand Surg Br; 1999 Aug; 24(4):476-81. PubMed ID: 10473162
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Stability of the distal phalanx fracture - A biomechanical study on the importance of the nail and the influence of fixation by crossing Kirschner wires.
    Wang W; Yu J; Fan CY; Liu S; Zheng X
    Clin Biomech (Bristol); 2016 Aug; 37():137-140. PubMed ID: 27451079
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fixation for comminuted phalangeal fractures. A biomechanical study of five methods.
    Lu WW; Furumachi K; Ip WY; Chow SP
    J Hand Surg Br; 1996 Dec; 21(6):765-7. PubMed ID: 8982920
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Spiral fracture fixation techniques. A biomechanical study.
    Matloub HS; Jensen PL; Sanger JR; Grunert BK; Yousif NJ
    J Hand Surg Br; 1993 Aug; 18(4):515-9. PubMed ID: 8409671
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Mechanical analysis of Kirschner wire fixation in a phalangeal model.
    Massengill JB; Alexander H; Parson JR; Schecter MJ
    J Hand Surg Am; 1979 Jul; 4(4):351-6. PubMed ID: 469212
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A biomechanical analysis of the stability of titanium bone fixation systems in proximal phalangeal fractures.
    Prevel CD; Katona T; Eppley BL; Moore K; McCarty M; Ge J
    Ann Plast Surg; 1996 Nov; 37(5):473-81. PubMed ID: 8937599
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biomechanical analysis of dorsal plate fixation in proximal phalangeal fractures.
    Damron TA; Jebson PJ; Rao VK; Engber WD; Norden MA
    Ann Plast Surg; 1994 Mar; 32(3):270-5. PubMed ID: 8192387
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Lesions of peripheral structures of cadaver fingers caused by Kirschner wires].
    Pointinger H; Munk P; Poeschl G; Schreiber M
    Unfallchirurg; 2000 Mar; 103(3):203-7. PubMed ID: 10800383
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Absorbable biologically based internal fixation.
    Ibrahim AM; Koolen PG; Kim K; Perrone GS; Kaplan DL; Lin SJ
    Clin Podiatr Med Surg; 2015 Jan; 32(1):61-72. PubMed ID: 25440418
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Rigid fixation of phalangeal and metacarpal fractures.
    Melone CP
    Orthop Clin North Am; 1986 Jul; 17(3):421-35. PubMed ID: 3737138
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Treatment of metacarpal and phalangeal fractures--a review].
    Zyluk A; Budzyński T
    Chir Narzadow Ruchu Ortop Pol; 2006; 71(4):299-308. PubMed ID: 17455531
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Bioresorbable fracture fixation in orthopedics: a comprehensive review. Part II. Clinical studies.
    Simon JA; Ricci JL; Di Cesare PE
    Am J Orthop (Belle Mead NJ); 1997 Nov; 26(11):754-62. PubMed ID: 9402210
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.