294 related articles for article (PubMed ID: 9571622)
1. Digital radiology using active matrix readout of amorphous selenium: detectors with high voltage protection.
Zhao W; Law J; Waechter D; Huang Z; Rowlands JA
Med Phys; 1998 Apr; 25(4):539-49. PubMed ID: 9571622
[TBL] [Abstract][Full Text] [Related]
2. Digital radiology using active matrix readout of amorphous selenium: radiation hardness of cadmium selenide thin film transistors.
Zhao W; Waechter D; Rowlands JA
Med Phys; 1998 Apr; 25(4):527-38. PubMed ID: 9571621
[TBL] [Abstract][Full Text] [Related]
3. Digital radiology using active matrix readout of amorphous selenium: construction and evaluation of a prototype real-time detector.
Zhao W; Blevis I; Germann S; Rowlands JA; Waechter D; Huang Z
Med Phys; 1997 Dec; 24(12):1834-43. PubMed ID: 9434966
[TBL] [Abstract][Full Text] [Related]
4. X-ray imaging using amorphous selenium: feasibility of a flat panel self-scanned detector for digital radiology.
Zhao W; Rowlands JA
Med Phys; 1995 Oct; 22(10):1595-604. PubMed ID: 8551983
[TBL] [Abstract][Full Text] [Related]
5. Digital radiology using active matrix readout of amorphous selenium: theoretical analysis of detective quantum efficiency.
Zhao W; Rowlands JA
Med Phys; 1997 Dec; 24(12):1819-33. PubMed ID: 9434965
[TBL] [Abstract][Full Text] [Related]
6. A framework for optimising the radiographic technique in digital X-ray imaging.
Samei E; Dobbins JT; Lo JY; Tornai MP
Radiat Prot Dosimetry; 2005; 114(1-3):220-9. PubMed ID: 15933112
[TBL] [Abstract][Full Text] [Related]
7. X-ray imaging using avalanche multiplication in amorphous selenium: investigation of depth dependent avalanche noise.
Hunt DC; Tanioka K; Rowlands JA
Med Phys; 2007 Mar; 34(3):976-86. PubMed ID: 17441244
[TBL] [Abstract][Full Text] [Related]
8. Theoretical investigation of the noise performance of active pixel imaging arrays based on polycrystalline silicon thin film transistors.
Koniczek M; Antonuk LE; El-Mohri Y; Liang AK; Zhao Q
Med Phys; 2017 Jul; 44(7):3491-3503. PubMed ID: 28376261
[TBL] [Abstract][Full Text] [Related]
9. Digital radiology using active matrix readout: amplified pixel detector array for fluoroscopy.
Matsuura N; Zhao W; Huang Z; Rowlands JA
Med Phys; 1999 May; 26(5):672-81. PubMed ID: 10360526
[TBL] [Abstract][Full Text] [Related]
10. The x-ray time of flight method for investigation of ghosting in amorphous selenium-based flat panel medical x-ray imagers.
Rau AW; Bakueva L; Rowlands JA
Med Phys; 2005 Oct; 32(10):3160-77. PubMed ID: 16279070
[TBL] [Abstract][Full Text] [Related]
11. Indirect flat-panel detector with avalanche gain: fundamental feasibility investigation for SHARP-AMFPI (scintillator HARP active matrix flat panel imager).
Zhao W; Li D; Reznik A; Lui BJ; Hunt DC; Rowlands JA; Ohkawa Y; Tanioka K
Med Phys; 2005 Sep; 32(9):2954-66. PubMed ID: 16266110
[TBL] [Abstract][Full Text] [Related]
12. Amorphous In-Ga-Zn-O thin-film transistor active pixel sensor x-ray imager for digital breast tomosynthesis.
Zhao C; Kanicki J
Med Phys; 2014 Sep; 41(9):091902. PubMed ID: 25186389
[TBL] [Abstract][Full Text] [Related]
13. Evaluation of the imaging properties of an amorphous selenium-based flat panel detector for digital fluoroscopy.
Hunt DC; Tousignant O; Rowlands JA
Med Phys; 2004 May; 31(5):1166-75. PubMed ID: 15191306
[TBL] [Abstract][Full Text] [Related]
14. Digital radiography using amorphous selenium: photoconductively activated switch (PAS) readout system.
Reznik N; Komljenovic PT; Germann S; Rowlands JA
Med Phys; 2008 Mar; 35(3):1039-50. PubMed ID: 18404939
[TBL] [Abstract][Full Text] [Related]
15. Direct-conversion flat-panel imager with avalanche gain: feasibility investigation for HARP-AMFPI.
Wronski MM; Rowlands JA
Med Phys; 2008 Dec; 35(12):5207-18. PubMed ID: 19175080
[TBL] [Abstract][Full Text] [Related]
16. Empirical investigation of the signal performance of a high-resolution, indirect detection, active matrix flat-panel imager (AMFPI) for fluoroscopic and radiographic operation.
Antonuk LE; El-Mohri Y; Siewerdsen JH; Yorkston J; Huang W; Scarpine VE; Street RA
Med Phys; 1997 Jan; 24(1):51-70. PubMed ID: 9029541
[TBL] [Abstract][Full Text] [Related]
17. Imaging performance of an amorphous selenium digital mammography detector in a breast tomosynthesis system.
Zhao B; Zhao W
Med Phys; 2008 May; 35(5):1978-87. PubMed ID: 18561674
[TBL] [Abstract][Full Text] [Related]
18. Projection X-ray Imaging: Radiography, Mammography, Fluoroscopy.
Seibert JA
Health Phys; 2019 Feb; 116(2):148-156. PubMed ID: 30585956
[TBL] [Abstract][Full Text] [Related]
19. The x-ray sensitivity of amorphous selenium for mammography.
Stone MF; Zhao W; Jacak BV; O'Connor P; Yu B; Rehak P
Med Phys; 2002 Mar; 29(3):319-24. PubMed ID: 11929014
[TBL] [Abstract][Full Text] [Related]
20. Design and feasibility of active matrix flat panel detector using avalanche amorphous selenium for protein crystallography.
Sultana A; Reznik A; Karim KS; Rowlands JA
Med Phys; 2008 Oct; 35(10):4324-32. PubMed ID: 18975678
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]