193 related articles for article (PubMed ID: 9572506)
1. Iterative and analytical reconstruction algorithms for varying-focal-length cone-beam projections.
Zeng GL; Gullberg GT
Phys Med Biol; 1998 Apr; 43(4):811-21. PubMed ID: 9572506
[TBL] [Abstract][Full Text] [Related]
2. Analytical fan-beam and cone-beam reconstruction algorithms with uniform attenuation correction for SPECT.
Tang Q; Zeng GL; Gullberg GT
Phys Med Biol; 2005 Jul; 50(13):3153-70. PubMed ID: 15972987
[TBL] [Abstract][Full Text] [Related]
3. Implementation of an accelerated iterative algorithm for cone-beam SPECT.
Li J; Jaszczak RJ; Greer KL; Coleman RE
Phys Med Biol; 1994 Mar; 39(3):643-53. PubMed ID: 15551605
[TBL] [Abstract][Full Text] [Related]
4. An analytical reconstruction algorithm for multifocal converging-beam SPECT.
Cao ZJ; Tsui BM
Phys Med Biol; 1994 Feb; 39(2):281-91. PubMed ID: 15552125
[TBL] [Abstract][Full Text] [Related]
5. A backprojection filtering algorithm for a spatially varying focal length collimator.
Zeng GL; Gullberg GT
IEEE Trans Med Imaging; 1994; 13(3):549-56. PubMed ID: 18218530
[TBL] [Abstract][Full Text] [Related]
6. Implementation of Tuy's cone-beam inversion formula.
Zeng GL; Clack R; Gullberg GT
Phys Med Biol; 1994 Mar; 39(3):493-507. PubMed ID: 15551594
[TBL] [Abstract][Full Text] [Related]
7. A filtering approach to image reconstruction in 3D SPECT.
Bronnikov AV
Phys Med Biol; 2000 Sep; 45(9):2639-51. PubMed ID: 11008962
[TBL] [Abstract][Full Text] [Related]
8. Brain SPECT with short focal-length cone-beam collimation.
Park MA; Moore SC; Kijewski MF
Med Phys; 2005 Jul; 32(7):2236-44. PubMed ID: 16121578
[TBL] [Abstract][Full Text] [Related]
9. Fan-beam reconstruction algorithm for a spatially varying focal length collimator.
Zeng GL; Gullberg GT; Jaszczak RJ; Li J
IEEE Trans Med Imaging; 1993; 12(3):575-82. PubMed ID: 18218451
[TBL] [Abstract][Full Text] [Related]
10. Interest of the ordered subsets expectation maximization (OS-EM) algorithm in pinhole single-photon emission tomography reconstruction: a phantom study.
Vanhove C; Defrise M; Franken PR; Everaert H; Deconinck F; Bossuyt A
Eur J Nucl Med; 2000 Feb; 27(2):140-6. PubMed ID: 10755718
[TBL] [Abstract][Full Text] [Related]
11. Benefits of angular expression to reconstruction algorithms for collimators with spatially varying focal lengths.
You J; Bao S; Liang Z
IEEE Trans Med Imaging; 1997 Oct; 16(5):527-31. PubMed ID: 9368108
[TBL] [Abstract][Full Text] [Related]
12. A harmonic decomposition reconstruction algorithm for spatially varying focal length collimators.
You J; Liang Z; Bao S
IEEE Trans Med Imaging; 1998 Dec; 17(6):995-1002. PubMed ID: 10048856
[TBL] [Abstract][Full Text] [Related]
13. Quantification and reduction of the collimator-detector response effect in SPECT by applying a system model during iterative image reconstruction: a simulation study.
Kalantari F; Rajabi H; Saghari M
Nucl Med Commun; 2012 Mar; 33(3):228-38. PubMed ID: 22134173
[TBL] [Abstract][Full Text] [Related]
14. A three-dimensional weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT under a circular source trajectory.
Tang X; Hsieh J; Hagiwara A; Nilsen RA; Thibault JB; Drapkin E
Phys Med Biol; 2005 Aug; 50(16):3889-905. PubMed ID: 16077234
[TBL] [Abstract][Full Text] [Related]
15. Exact fan-beam and 4pi-acquisition cone-beam SPECT algorithms with uniform attenuation correction.
Tang Q; Zeng GL; Wu J; Gullberg GT
Med Phys; 2005 Nov; 32(11):3440-7. PubMed ID: 16372416
[TBL] [Abstract][Full Text] [Related]
16. Iterative three-dimensional expectation maximization restoration of single photon emission computed tomography images: application in striatal imaging.
Gantet P; Payoux P; Celler A; Majorel C; Gourion D; Noll D; Esquerré JP
Med Phys; 2006 Jan; 33(1):52-60. PubMed ID: 16485409
[TBL] [Abstract][Full Text] [Related]
17. Astigmatic single photon emission computed tomography imaging with a displaced center of rotation.
Wang H; Smith MF; Stone CD; Jaszczak RJ
Med Phys; 1998 Aug; 25(8):1493-501. PubMed ID: 9725140
[TBL] [Abstract][Full Text] [Related]
18. Analytical cone-beam SPECT reconstruction algorithm with non-uniform attenuation for general non-circular orbit.
Wen J; Zhang K; Li C; Liang Z
Comput Biol Med; 2013 Sep; 43(9):1221-33. PubMed ID: 23930817
[TBL] [Abstract][Full Text] [Related]
19. Iterative reconstruction of fluorine-18 SPECT using geometric point response correction.
Zeng GL; Gullberg GT; Bai C; Christian PE; Trisjono F; Di Bella EV; Tanner JW; Morgan HT
J Nucl Med; 1998 Jan; 39(1):124-30. PubMed ID: 9443751
[TBL] [Abstract][Full Text] [Related]
20. Transmission imaging for nonuniform attenuation correction using a three-headed SPECT camera.
Gilland DR; Jaszczak RJ; Greer KL; Coleman RE
J Nucl Med; 1998 Jun; 39(6):1105-10. PubMed ID: 9627354
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]