BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

179 related articles for article (PubMed ID: 9572513)

  • 1. The effect of activity outside the direct field of view in a 3D-only whole-body positron tomograph.
    Spinks TJ; Miller MP; Bailey DL; Bloomfield PM; Livieratos L; Jones T
    Phys Med Biol; 1998 Apr; 43(4):895-904. PubMed ID: 9572513
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Physical characteristics of the ECAT EXACT3D positron tomograph.
    Spinks TJ; Jones T; Bloomfield PM; Bailey DL; Miller M; Hogg D; Jones WF; Vaigneur K; Reed J; Young J; Newport D; Moyers C; Casey ME; Nutt R
    Phys Med Biol; 2000 Sep; 45(9):2601-18. PubMed ID: 11008960
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Experience with fully 3D PET and implications for future high-resolution 3D tomographs.
    Bailey DL; Miller MP; Spinks TJ; Bloomfield PM; Livieratos L; Young HE; Jones T
    Phys Med Biol; 1998 Apr; 43(4):777-86. PubMed ID: 9572503
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Imaging characteristics of a 3-dimensional GSO whole-body PET camera.
    Surti S; Karp JS
    J Nucl Med; 2004 Jun; 45(6):1040-9. PubMed ID: 15181139
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effects of system geometry and other physical factors on photon sensitivity of high-resolution positron emission tomography.
    Habte F; Foudray AM; Olcott PD; Levin CS
    Phys Med Biol; 2007 Jul; 52(13):3753-72. PubMed ID: 17664575
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The design and physical characteristics of a small animal positron emission tomograph.
    Bloomfield PM; Rajeswaran S; Spinks TJ; Hume SP; Myers R; Ashworth S; Clifford KM; Jones WF; Byars LG; Young J
    Phys Med Biol; 1995 Jun; 40(6):1105-26. PubMed ID: 7659733
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Performance evaluation of microPET: a high-resolution lutetium oxyorthosilicate PET scanner for animal imaging.
    Chatziioannou AF; Cherry SR; Shao Y; Silverman RW; Meadors K; Farquhar TH; Pedarsani M; Phelps ME
    J Nucl Med; 1999 Jul; 40(7):1164-75. PubMed ID: 10405138
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Inter-crystal scatter in a dual layer, high resolution LSO-APD positron emission tomograph.
    Rafecas M; Böning G; Pichler BJ; Lorenz E; Schwaiger M; Ziegler SI
    Phys Med Biol; 2003 Apr; 48(7):821-48. PubMed ID: 12701889
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Performance evaluation of the microPET P4: a PET system dedicated to animal imaging.
    Tai C; Chatziioannou A; Siegel S; Young J; Newport D; Goble RN; Nutt RE; Cherry SR
    Phys Med Biol; 2001 Jul; 46(7):1845-62. PubMed ID: 11474929
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Three-dimensional performance of a small-diameter positron emission tomograph.
    Bloomfield PM; Myers R; Hume SP; Spinks TJ; Lammertsma AA; Jones T
    Phys Med Biol; 1997 Feb; 42(2):389-400. PubMed ID: 9044420
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A prototype high-resolution animal positron tomograph with avalanche photodiode arrays and LSO crystals.
    Ziegler SI; Pichler BJ; Boening G; Rafecas M; Pimpl W; Lorenz E; Schmitz N; Schwaiger M
    Eur J Nucl Med; 2001 Feb; 28(2):136-43. PubMed ID: 11303882
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Performance characteristics of a new 3-dimensional continuous-emission and spiral-transmission high-sensitivity and high-resolution PET camera evaluated with the NEMA NU 2-2001 standard.
    Matsumoto K; Kitamura K; Mizuta T; Tanaka K; Yamamoto S; Sakamoto S; Nakamoto Y; Amano M; Murase K; Senda M
    J Nucl Med; 2006 Jan; 47(1):83-90. PubMed ID: 16391191
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Three-dimensional imaging characteristics of the HEAD PENN-PET scanner.
    Karp JS; Freifelder R; Geagan MJ; Muehllehner G; Kinahan PE; Lewitt RM; Shao L
    J Nucl Med; 1997 Apr; 38(4):636-43. PubMed ID: 9098216
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Physical aspects of cardiac scanning with a block detector positron tomograph.
    Spinks TJ; Araujo LI; Rhodes CG; Hutton BF
    J Comput Assist Tomogr; 1991; 15(5):893-904. PubMed ID: 1885821
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Image quality assessment of LaBr3-based whole-body 3D PET scanners: a Monte Carlo evaluation.
    Surti S; Karp JS; Muehllehner G
    Phys Med Biol; 2004 Oct; 49(19):4593-610. PubMed ID: 15552419
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Investigation of scattered radiation in 3D whole-body positron emission tomography using Monte Carlo simulations.
    Adam LE; Karp JS; Brix G
    Phys Med Biol; 1999 Dec; 44(12):2879-95. PubMed ID: 10616142
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The effects of collimation on PET image noise due to scatter, random counts, and deadtime.
    Thompson CJ
    J Cereb Blood Flow Metab; 1991 Mar; 11(2):A31-7. PubMed ID: 1997485
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Physical performance of a positron tomograph for brain imaging with retractable septa.
    Spinks TJ; Jones T; Bailey DL; Townsend DW; Grootoonk S; Bloomfield PM; Gilardi MC; Casey ME; Sipe B; Reed J
    Phys Med Biol; 1992 Aug; 37(8):1637-55. PubMed ID: 1518905
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Performance evaluation of the new whole-body PET/CT scanner: Discovery ST.
    Bettinardi V; Danna M; Savi A; Lecchi M; Castiglioni I; Gilardi MC; Bammer H; Lucignani G; Fazio F
    Eur J Nucl Med Mol Imaging; 2004 Jun; 31(6):867-81. PubMed ID: 14770270
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The ECAT EXACT HR: performance of a new high resolution positron scanner.
    Wienhard K; Dahlbom M; Eriksson L; Michel C; Bruckbauer T; Pietrzyk U; Heiss WD
    J Comput Assist Tomogr; 1994; 18(1):110-8. PubMed ID: 8282858
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]