BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

863 related articles for article (PubMed ID: 9577178)

  • 1. [Evaluation of the polyethyleneglycol antiglobulin test in the detection and identification of erythrocyte antibodies].
    Jiménez Marco MT; Hernández Maraver D; Rodríguez de la Rua A; de la Cámara Mendizábal C; Canales Albendea M; Jiménez Yuste V; Hernández Navarro F
    Sangre (Barc); 1998 Feb; 43(1):21-4. PubMed ID: 9577178
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Value of using polyethylene glycol in the indirect antiglobulin test with erythrocytes].
    Michalewska B; Walewska I; Seyfriedowa H; Kuśnierz-Alejska G
    Acta Haematol Pol; 1991; 22(1):105-12. PubMed ID: 1823951
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of the polyethylene glycol-indirect antiglobulin test for routine compatibility testing.
    Slater JL; Griswold DJ; Wojtyniak LS; Reisling MJ
    Transfusion; 1989 Oct; 29(8):686-8. PubMed ID: 2799893
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Indirect antiglobulin test-crossmatch using low-ionic-strength saline-albumin enhancement medium and reduced incubation time: effectiveness in the detection of most clinically significant antibodies and impact on blood utilization.
    Dinardo CL; Bonifácio SL; Mendrone A
    Immunohematology; 2014; 30(1):1-5. PubMed ID: 25238242
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Comparison of several methods for detecting anti-erythrocyte alloantibodies].
    Bencomo AA
    Sangre (Barc); 1990 Aug; 35(4):307-10. PubMed ID: 2125752
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Antibody identification using both automated solid-phase red cell adherence assay and a tube polyethylene glycol antiglobulin method.
    Yamada C; Serrano-Rahman L; Vasovic LV; Mohandas K; Uehlinger J
    Transfusion; 2008 Aug; 48(8):1693-8. PubMed ID: 18482178
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Polyethylene glycol versus low-ionic-strength solution in pretransfusion testing: a blinded comparison study.
    Shirey RS; Boyd JS; Ness PM
    Transfusion; 1994 May; 34(5):368-70. PubMed ID: 8191557
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Polyethylene glycol improves the indirect antiglobulin test.
    Wenz B; Apuzzo J
    Transfusion; 1989; 29(3):218-20. PubMed ID: 2922789
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of a modified IAT-gel with polyethylenglycol (PEG) addition method for red blood cell antibody identification.
    Gustafsson L; Wikman A; Lundahl J
    J Clin Lab Anal; 2004; 18(3):165-9. PubMed ID: 15103680
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of the polyethylene glycol antiglobulin test for detection of red blood cell antibodies.
    de Man AJ; Overbeeke MA
    Vox Sang; 1990; 58(3):207-10. PubMed ID: 2339531
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [3 new antibody detection tests. A comparative study].
    Mempel W; Alraun K; Leeping M; Kirschner M; Reiser H; Heim MU
    Beitr Infusionsther; 1990; 26():362-6. PubMed ID: 1703872
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Two-stage papain-indirect antiglobulin test and LISS direct agglutination are not appropriate for pretransfusion screening for unexpected antibodies.
    Pereira A; Mazzara R; Gelabert A; Castillo R
    Haematologica; 1991; 76(6):475-8. PubMed ID: 1820984
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Revisiting the issue: can the reading for serologic reactivity following 37 degrees C incubation be omitted?
    Judd WJ; Fullen DR; Steiner EA; Davenport RD; Knafl PC
    Transfusion; 1999 Mar; 39(3):295-9. PubMed ID: 10204593
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Solid phase technique versus gel centrifugation for detection of erythrocyte antibodies--a prospective study comparison the 2 antibody detection tests].
    Zeiler T; Thiele S; Kretschmer V
    Beitr Infusionsther Transfusionsmed; 1996; 33():17-21. PubMed ID: 8974691
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Can the reading for serologic reactivity following 37 degrees C incubation be omitted?
    Judd WJ; Steiner EA; Oberman HA; Nance SJ
    Transfusion; 1992 May; 32(4):304-8. PubMed ID: 1585433
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Evaluation of the test using polybrene for the detection of anti-erythrocyte antibodies].
    Lenkiewicz B
    Acta Haematol Pol; 1991; 22(1):127-35. PubMed ID: 1823954
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of low ionic diluents for use with the Diamed antiglobulin gel test.
    Grey D; Connolly M; Erber WN
    Transfus Med; 2002 Feb; 12(1):63-9. PubMed ID: 11967139
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of recent techniques for detection of red blood cell antibodies in sera of reference samples, patients, pregnant women, and blood donors.
    de Castilho LM; Pellegrino J; Bechelli AP; Le Pennec PY; Mendes NF
    J Clin Lab Anal; 1996; 10(5):250-6. PubMed ID: 8887003
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A new potentiator of red blood cell antigen-antibody reactions.
    Nance SJ; Garratty G
    Am J Clin Pathol; 1987 May; 87(5):633-5. PubMed ID: 3578138
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of a manual hexadimethrine bromide-antiglobulin test with saline- and albumin-antiglobulin tests for pretransfusion testing.
    Mintz PD; Anderson G
    Transfusion; 1987; 27(2):134-7. PubMed ID: 3824470
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 44.