These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
179 related articles for article (PubMed ID: 9579266)
1. Triggering delay time and work of breathing in three paediatric patient-triggered ventilators. Nakae Y; Yamakage M; Horikawa D; Aimono M; Tamiya K; Namiki A Can J Anaesth; 1998 Mar; 45(3):261-5. PubMed ID: 9579266 [TBL] [Abstract][Full Text] [Related]
2. Mechanical ventilators optimized for pediatric use decrease work of breathing and oxygen consumption during pressure-support ventilation. el-Khatib MF; Chatburn RL; Potts DL; Blumer JL; Smith PG Crit Care Med; 1994 Dec; 22(12):1942-8. PubMed ID: 7988130 [TBL] [Abstract][Full Text] [Related]
3. Pressure support and pressure assist/control: are there differences? An evaluation of the newest intensive care unit ventilators. Williams P; Kratohvil J; Ritz R; Hess DR; Kacmarek RM Respir Care; 2000 Oct; 45(10):1169-81. PubMed ID: 11054896 [TBL] [Abstract][Full Text] [Related]
4. An evaluation of Automode, a computer-controlled ventilator mode, with the Siemens Servo 300A ventilator, using a porcine model. Holt SJ; Sanders RC; Thurman TL; Heulitt MJ Respir Care; 2001 Jan; 46(1):26-36. PubMed ID: 11175235 [TBL] [Abstract][Full Text] [Related]
5. Comparison of total resistive work of breathing in two generations of ventilators in an animal model. Heulitt MJ; Torres A; Anders M; Wilson SW; Carmack J Pediatr Pulmonol; 1996 Jul; 22(1):58-66. PubMed ID: 8856804 [TBL] [Abstract][Full Text] [Related]
6. Effects of continuous positive airway pressure/positive end-expiratory pressure and pressure-support ventilation on work of breathing, using an animal model. Heulitt MJ; Holt SJ; Wilson S; Hall RA Respir Care; 2003 Jul; 48(7):689-96. PubMed ID: 12841860 [TBL] [Abstract][Full Text] [Related]
7. The effect of ventilator performance on airway pressure release ventilation: a model lung study. Yoshida T; Uchiyama A; Mashimo T; Fujino Y Anesth Analg; 2011 Sep; 113(3):529-33. PubMed ID: 21519042 [TBL] [Abstract][Full Text] [Related]
8. Effects of inspiratory rise time on triggering work load during pressure-support ventilation: a lung model study. Murata S; Yokoyama K; Sakamoto Y; Yamashita K; Oto J; Imanaka H; Nishimura M Respir Care; 2010 Jul; 55(7):878-84. PubMed ID: 20587100 [TBL] [Abstract][Full Text] [Related]
9. Patient-triggered ventilation: a comparison of tidal volume and chestwall and abdominal motion as trigger signals. Nikischin W; Gerhardt T; Everett R; Gonzalez A; Hummler H; Bancalari E Pediatr Pulmonol; 1996 Jul; 22(1):28-34. PubMed ID: 8856801 [TBL] [Abstract][Full Text] [Related]
10. Work of breathing in adaptive pressure control continuous mandatory ventilation. Mireles-Cabodevila E; Chatburn RL Respir Care; 2009 Nov; 54(11):1467-72. PubMed ID: 19863830 [TBL] [Abstract][Full Text] [Related]
11. The effects of tidal volume demand on work of breathing during simulated lung-protective ventilation. Kallet RH; Alonso JA; Diaz M; Campbell AR; Mackersie RC; Katz JA Respir Care; 2002 Aug; 47(8):898-909. PubMed ID: 12162801 [TBL] [Abstract][Full Text] [Related]
12. Using tracheal pressure to trigger the ventilator and control airway pressure during continuous positive airway pressure decreases work of breathing. Messinger G; Banner MJ; Blanch PB; Layon AJ Chest; 1995 Aug; 108(2):509-14. PubMed ID: 7634891 [TBL] [Abstract][Full Text] [Related]
13. Validation and clinical application of a continuous P0.1 measurement using standard respiratory equipment. Kuhlen R; Mohnhaupt R; Slama K; Hausmann S; Pappert D; Rossaint R; Falke K Technol Health Care; 1996 Dec; 4(4):415-24. PubMed ID: 9042692 [TBL] [Abstract][Full Text] [Related]
14. The impact of imposed expiratory resistance in neonatal mechanical ventilation: a laboratory evaluation. DiBlasi RM; Salyer JW; Zignego JC; Redding GJ; Richardson CP Respir Care; 2008 Nov; 53(11):1450-60. PubMed ID: 18957147 [TBL] [Abstract][Full Text] [Related]
15. [Quantitative comparison of ventilator-induced work during simulated CPAP in eight demand-flow valve ventilators]. Nishimura M; Imanaka H; Taenaka N; Yoshiya I; Takezawa J Masui; 1989 Aug; 38(8):1017-29. PubMed ID: 2681861 [TBL] [Abstract][Full Text] [Related]
16. Spontaneously breathing lung model comparison of work of breathing between automatic tube compensation and pressure support. Fujino Y; Uchiyama A; Mashimo T; Nishimura M Respir Care; 2003 Jan; 48(1):38-45. PubMed ID: 12556260 [TBL] [Abstract][Full Text] [Related]
17. Evaluation of inspiratory rise time and inspiration termination criteria in new-generation mechanical ventilators: a lung model study. Chatmongkolchart S; Williams P; Hess DR; Kacmarek RM Respir Care; 2001 Jul; 46(7):666-77. PubMed ID: 11403698 [TBL] [Abstract][Full Text] [Related]
18. Effect of ventilation equipment on imposed work of breathing. French CJ; Bellomo R; Buckmaster J Crit Care Resusc; 2001 Sep; 3(3):148-52. PubMed ID: 16573494 [TBL] [Abstract][Full Text] [Related]
19. Accuracy of tidal volume, compliance, and resistance measurements on neonatal ventilator displays: an in vitro assessment. Abbasi S; Sivieri E; Roberts R; Kirpalani H Pediatr Crit Care Med; 2012 Jul; 13(4):e262-8. PubMed ID: 22596072 [TBL] [Abstract][Full Text] [Related]
20. Effect of inspiratory time on tidal volume delivery in anesthesia and intensive care unit ventilators operating in pressure control mode. Tung A; Drum ML; Morgan S J Clin Anesth; 2005 Feb; 17(1):8-15. PubMed ID: 15721723 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]