These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
124 related articles for article (PubMed ID: 9584302)
1. Microwave catheter ablation using a clinical prototype system with a lateral firing antenna design. Liem LB; Mead RH; Shenasa M; Chun S; Hayase M; Kernoff R Pacing Clin Electrophysiol; 1998 Apr; 21(4 Pt 1):714-21. PubMed ID: 9584302 [TBL] [Abstract][Full Text] [Related]
2. In vitro and in vivo results of transcatheter microwave ablation using forward-firing tip antenna design. Liem LB; Mead RH; Shenasa M; Kernoff R Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 2):2004-8. PubMed ID: 8945086 [TBL] [Abstract][Full Text] [Related]
3. Microwave linear ablation of the isthmus between the inferior vena cava and tricuspid annulus. Liem LB; Mead RH Pacing Clin Electrophysiol; 1998 Nov; 21(11 Pt 1):2079-86. PubMed ID: 9826860 [TBL] [Abstract][Full Text] [Related]
4. Microwave ablation of the atrioventricular junction in open-chest dogs. Lin JC; Beckman KJ; Hariman RJ; Bharati S; Lev M; Wang YJ Bioelectromagnetics; 1995; 16(2):97-105. PubMed ID: 7612031 [TBL] [Abstract][Full Text] [Related]
5. Catheter ablation of the atrioventricular junction using a helical microwave antenna: a novel means of coupling energy to the endocardium. Langberg JJ; Wonnell T; Chin MC; Finkbeiner W; Scheinman M; Stauffer P Pacing Clin Electrophysiol; 1991 Dec; 14(12):2105-13. PubMed ID: 1723193 [TBL] [Abstract][Full Text] [Related]
7. Microwave ablation of the atrioventricular junction in vivo and ventricular myocardium in vitro and in vivo. Effects of varying power and duration on lesion volume. Yang X; Watanabe I; Kojima T; Takahashi Y; Kanada A; Kunimoto S; Kasamaki Y; Kondo K; Saito S; Ozawa Y Jpn Heart J; 1994 Mar; 35(2):175-91. PubMed ID: 8022062 [TBL] [Abstract][Full Text] [Related]
8. Safety and efficacy of a steerable temperature monitoring microwave catheter system for ventricular myocardial ablation. VanderBrink BA; Gilbride C; Aronovitz MJ; Lenihan T; Schorn G; Taylor K; Regan JF; Carr K; Schoen FJ; Link MS; Homoud MK; Estes NA; Wang PJ J Cardiovasc Electrophysiol; 2000 Mar; 11(3):305-10. PubMed ID: 10749353 [TBL] [Abstract][Full Text] [Related]
9. Modification of atrioventricular conduction using a combined laser-electrode catheter. Curtis AB; Mansour M; Friedl SE; Tomaru T; Barbeau GR; Normann SJ; Abela GS Pacing Clin Electrophysiol; 1994 Mar; 17(3 Pt 1):337-48. PubMed ID: 7513859 [TBL] [Abstract][Full Text] [Related]
10. Microwave ablation using a spiral antenna design in a porcine thigh muscle preparation: in vivo assessment of temperature profile and lesion geometry. Vanderbrink BA; Gu Z; Rodriguez V; Link MS; Homoud MK; Estes NA; Rappaport CM; Wang PJ J Cardiovasc Electrophysiol; 2000 Feb; 11(2):193-8. PubMed ID: 10709714 [TBL] [Abstract][Full Text] [Related]
11. Closed chest catheter desiccation of the atrioventricular junction using radiofrequency energy--a new method of catheter ablation. Huang SK; Bharati S; Graham AR; Lev M; Marcus FI; Odell RC J Am Coll Cardiol; 1987 Feb; 9(2):349-58. PubMed ID: 3805526 [TBL] [Abstract][Full Text] [Related]
12. A Novel Microwave Catheter Can Perform Noncontact Circumferential Endocardial Ablation in a Model of Pulmonary Vein Isolation. Qian P; Barry MA; Nguyen T; Ross D; Kovoor P; McEwan A; Thomas S; Thiagalingam A J Cardiovasc Electrophysiol; 2015 Jul; 26(7):799-804. PubMed ID: 25871772 [TBL] [Abstract][Full Text] [Related]
13. In vitro and in vivo evaluation of the thermal patterns and lesions of catheter ablation with a microwave monopole antenna. Keane D; Ruskin J; Norris N; Chapelon PA; Bérubé D J Interv Card Electrophysiol; 2004 Apr; 10(2):111-9. PubMed ID: 15014211 [TBL] [Abstract][Full Text] [Related]
14. Catheter ablation using very high frequency current: effects on the atrioventricular junction and ventricular myocardium in sheep. Bru P; Lauribe P; Rouane A; Nadi M; Prieur G; Ricard P; De CC; Aliot E; Lévy S Europace; 2002 Jan; 4(1):69-75. PubMed ID: 11846319 [TBL] [Abstract][Full Text] [Related]
15. Cardiac tissue ablation with catheter-based microwave heating. Rappaport C Int J Hyperthermia; 2004 Nov; 20(7):769-80. PubMed ID: 15675671 [TBL] [Abstract][Full Text] [Related]
17. Catheter ablation of atrioventricular junction using radiofrequency current in 17 patients. Comparison of standard and large-tip catheter electrodes. Jackman WM; Wang XZ; Friday KJ; Fitzgerald DM; Roman C; Moulton K; Margolis PD; Bowman AJ; Kuck KH; Naccarelli GV Circulation; 1991 May; 83(5):1562-76. PubMed ID: 2022016 [TBL] [Abstract][Full Text] [Related]
18. Correlation of temperature and pathophysiological effect during radiofrequency catheter ablation of the AV junction. Nath S; DiMarco JP; Mounsey JP; Lobban JH; Haines DE Circulation; 1995 Sep; 92(5):1188-92. PubMed ID: 7648664 [TBL] [Abstract][Full Text] [Related]
19. Temperature-controlled radiofrequency catheter ablation of AV conduction: first clinical experience. Hoffmann E; Mattke S; Dorwarth U; Müller D; Haberl R; Steinbeck G Eur Heart J; 1993 Jan; 14(1):57-64. PubMed ID: 8432293 [TBL] [Abstract][Full Text] [Related]
20. Electroanatomic mapping and radiofrequency ablation of porcine left atria and atrioventricular nodes using magnetic resonance catheter tracking. Schmidt EJ; Mallozzi RP; Thiagalingam A; Holmvang G; d'Avila A; Guhde R; Darrow R; Slavin GS; Fung MM; Dando J; Foley L; Dumoulin CL; Reddy VY Circ Arrhythm Electrophysiol; 2009 Dec; 2(6):695-704. PubMed ID: 19841033 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]