These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

280 related articles for article (PubMed ID: 9584303)

  • 1. Failure of third-generation implantable cardioverter defibrillators to abort shock therapy for nonsustained ventricular tachycardia due to shortcomings of the VF confirmation algorithm.
    Grimm W; Menz V; Hoffmann J; Maisch B
    Pacing Clin Electrophysiol; 1998 Apr; 21(4 Pt 1):722-7. PubMed ID: 9584303
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Importance of abortive shock capability with electrogram storage in cardioverter-defibrillator devices.
    Hurwitz JL; Hook BG; Flores BT; Marchlinski FE
    J Am Coll Cardiol; 1993 Mar; 21(4):895-900. PubMed ID: 8450157
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Symptoms and electrocardiographically documented rhythm preceding spontaneous shocks in patients with implantable cardioverter-defibrillator.
    Grimm W; Flores BF; Marchlinski FE
    Am J Cardiol; 1993 Jun; 71(16):1415-8. PubMed ID: 8517386
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Implantable cardioverter defribrillator shocks: a troubleshooting guide.
    Swerdlow CD; Zhang J
    Rev Cardiovasc Med; 2001; 2(2):61-72. PubMed ID: 12439383
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Implantable defibrillator event rates in patients with idiopathic dilated cardiomyopathy, nonsustained ventricular tachycardia on Holter and a left ventricular ejection fraction below 30%.
    Grimm W; Hoffmann J Jü; Müller HH; Maisch B
    J Am Coll Cardiol; 2002 Mar; 39(5):780-7. PubMed ID: 11869841
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Inappropriate shock delivery by implantable defibrillators with dual chamber pacing during nonsustained ventricular tachycardia in patients with heart block.
    Sra J; Akhtar M
    Pacing Clin Electrophysiol; 2000 Jun; 23(6):1054-6. PubMed ID: 10879396
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of a programming algorithm for the third tachycardia zone in a fourth-generation implantable cardioverter-defibrillator.
    Neglia JJ; Krol RB; Giorgberidze I; Mathew P; Lewis C; Munsif AN; Saksena S
    J Interv Card Electrophysiol; 1997 Feb; 1(1):49-56. PubMed ID: 9869951
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Programmed ventricular stimulation for arrhythmia risk prediction in patients with idiopathic dilated cardiomyopathy and nonsustained ventricular tachycardia.
    Grimm W; Hoffmann J; Menz V; Luck K; Maisch B
    J Am Coll Cardiol; 1998 Sep; 32(3):739-45. PubMed ID: 9741521
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Implantable cardioverter defibrillator events in patients with asymptomatic nonsustained ventricular tachycardia: is device implantation justified?
    Russo AM; Nayak H; Verdino R; Springman J; Gerstenfeld E; Hsia H; Marchlinski FE
    Pacing Clin Electrophysiol; 2003 Dec; 26(12):2289-95. PubMed ID: 14675014
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Strategic programming of detection and therapy parameters in implantable cardioverter-defibrillators reduces shocks in primary prevention patients: results from the PREPARE (Primary Prevention Parameters Evaluation) study.
    Wilkoff BL; Williamson BD; Stern RS; Moore SL; Lu F; Lee SW; Birgersdotter-Green UM; Wathen MS; Van Gelder IC; Heubner BM; Brown ML; Holloman KK;
    J Am Coll Cardiol; 2008 Aug; 52(7):541-50. PubMed ID: 18687248
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Electrocardiographically documented unnecessary, spontaneous shocks in 241 patients with implantable cardioverter defibrillators.
    Grimm W; Flores BF; Marchlinski FE
    Pacing Clin Electrophysiol; 1992 Nov; 15(11 Pt 1):1667-73. PubMed ID: 1279533
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Predictive value of ventricular arrhythmia inducibility for subsequent ventricular tachycardia or ventricular fibrillation in Multicenter Automatic Defibrillator Implantation Trial (MADIT) II patients.
    Daubert JP; Zareba W; Hall WJ; Schuger C; Corsello A; Leon AR; Andrews ML; McNitt S; Huang DT; Moss AJ;
    J Am Coll Cardiol; 2006 Jan; 47(1):98-107. PubMed ID: 16386671
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Programming of implantable cardioverter-defibrillators on the basis of the upper limit of vulnerability.
    Swerdlow CD; Peter CT; Kass RM; Gang ES; Mandel WJ; Hwang C; Martin DJ; Chen PS
    Circulation; 1997 Mar; 95(6):1497-504. PubMed ID: 9118518
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Results of delivered therapy for VT or VF in patients with third-generation implantable cardioverter defibrillators.
    Rabinovich R; Muratore C; Iglesias R; Gonzalez M; Serafrica M; Sosa Liprandi A
    Pacing Clin Electrophysiol; 1995 Jan; 18(1 Pt 2):133-6. PubMed ID: 7724386
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Extravascular Implantable Cardioverter-Defibrillator Sensing and Detection in a Large Global Population.
    Swerdlow C; Gillberg J; Boersma LVA; Manlucu J; Zhang X; Zhang Y; Hernandez AA; Bhatia V; Murgatroyd F
    JACC Clin Electrophysiol; 2024 Aug; 10(8):1896-1912. PubMed ID: 38752961
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ventricular Tachyarrhythmias in Patients With Hypertrophic Cardiomyopathy and Defibrillators: Triggers, Treatment, and Implications.
    Link MS; Bockstall K; Weinstock J; Alsheikh-Ali AA; Semsarian C; Estes NAM; Spirito P; Haas TS; Rowin EJ; Maron MS; Maron BJ
    J Cardiovasc Electrophysiol; 2017 May; 28(5):531-537. PubMed ID: 28240435
    [TBL] [Abstract][Full Text] [Related]  

  • 17. High amplitude T-wave alternans precedes spontaneous ventricular tachycardia or fibrillation in ICD electrograms.
    Swerdlow CD; Zhou X; Voroshilovsky O; Abeyratne A; Gillberg J
    Heart Rhythm; 2008 May; 5(5):670-6. PubMed ID: 18452868
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Failure to detect life-threatening arrhythmias in ICDs using single-chamber detection criteria.
    Stroobandt RX; Duytschaever MF; Strisciuglio T; Van Heuverswyn FE; Timmers L; De Pooter J; Knecht S; Vandekerckhove YR; Kucher A; Tavernier RH
    Pacing Clin Electrophysiol; 2019 Jun; 42(6):583-594. PubMed ID: 30657188
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Ventricular tachycardia during follow-up in patients resuscitated from ventricular fibrillation: experience from stored electrograms of implantable cardioverter-defibrillators.
    Rüppel R; Schlüter CA; Boczor S; Meinertz T; Schlüter M; Kuck KH; Cappato R
    J Am Coll Cardiol; 1998 Nov; 32(6):1724-30. PubMed ID: 9822102
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Performance of an ICD algorithm to detect lead noise and reduce inappropriate shocks.
    Beau S; Greer S; Ellis CR; Keeney J; Asopa S; Arnold E; Fischer A
    J Interv Card Electrophysiol; 2016 Mar; 45(2):225-32. PubMed ID: 26739482
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.