BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 9586716)

  • 1. Modification of a linear accelerator table top for non-coplanar conformal brain radiotherapy.
    Fodor J; Breneman JC; Lamba MA; Foster AE; Elson H
    Med Dosim; 1998; 23(1):27-9. PubMed ID: 9586716
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Variation in the isocentre of a Philips linear accelerator (SL-20) used for stereotactic radiosurgery/stereotactic radiotherapy.
    D'Souza H; Joshi RC; Ganesh T; Subramani V; Vasu G; Kumar R; Julka PK; Rath GK
    Australas Radiol; 1999 Aug; 43(3):342-5. PubMed ID: 10901931
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Collision indicator charts for gantry-couch position combinations for Siemens ONCOR and Elekta Infinity linacs.
    Becker SJ; Culberson W; Flynn R
    J Appl Clin Med Phys; 2013 Sep; 14(5):278-83. PubMed ID: 24036873
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Quality assurance of non-coplanar, volumetric-modulated arc therapy employing a C-arm linear accelerator, featuring continuous patient couch rotation.
    Hirashima H; Nakamura M; Miyabe Y; Mukumoto N; Ono T; Iramina H; Mizowaki T
    Radiat Oncol; 2019 Apr; 14(1):62. PubMed ID: 30971273
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Quality control methods for linear accelerator radiation and mechanical axes alignment.
    Létourneau D; Keller H; Becker N; Amin MN; Norrlinger B; Jaffray DA
    Med Phys; 2018 Jun; 45(6):2388-2398. PubMed ID: 29645282
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Collision indicator charts for gantry-couch position combinations for Varian linacs.
    Becker SJ
    J Appl Clin Med Phys; 2011 Mar; 12(3):3405. PubMed ID: 21844849
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Improved accuracy for noncoplanar radiotherapy: an EPID-based method for submillimeter alignment of linear accelerator table rotation with MV isocenter.
    Nyflot MJ; Cao N; Meyer J; Ford EC
    J Appl Clin Med Phys; 2014 Mar; 15(2):4682. PubMed ID: 24710457
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of the mechanical alignment of a linear accelerator with an electronic portal imaging device (EPID).
    Liu G; van Doorn T; Bezak E
    Australas Phys Eng Sci Med; 2000 Sep; 23(3):74-80. PubMed ID: 11210157
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A system for stereotactic radiosurgery with a linear accelerator.
    Lutz W; Winston KR; Maleki N
    Int J Radiat Oncol Biol Phys; 1988 Feb; 14(2):373-81. PubMed ID: 3276655
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Generation and verification of QFix kVue Calypso-compatible couch top model for a dedicated stereotactic linear accelerator with FFF beams.
    Gardner SJ; Gulam M; Song K; Li H; Huang Y; Zhao B; Qin Y; Snyder K; Kim J; Gordon J; Chetty IJ; Wen N
    J Appl Clin Med Phys; 2015 Jul; 16(4):163–180. PubMed ID: 26219010
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dynamic trajectory-based couch motion for improvement of radiation therapy trajectories in cranial SRT.
    MacDonald RL; Thomas CG
    Med Phys; 2015 May; 42(5):2317-25. PubMed ID: 25979026
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Photon beam attenuation for a patient support assembly during arc therapy for a medical linear accelerator.
    Sharma SC; Johnson MW
    Med Dosim; 1992; 17(4):225-8. PubMed ID: 1485913
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Technical note: A collision prediction tool using Blender.
    Guyer G; Mueller S; Wyss Y; Bertholet J; Schmid R; Stampanoni MFM; Manser P; Fix MK
    J Appl Clin Med Phys; 2023 Nov; 24(11):e14165. PubMed ID: 37782250
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Collision Risk Mitigation of Varian TrueBeam Linear Accelerator With Supplemental Live-View Cameras.
    Nguyen SM; Chlebik AA; Olch AJ; Wong KK
    Pract Radiat Oncol; 2019 Jan; 9(1):e103-e109. PubMed ID: 30017785
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Development of a compact X-band linear accelerator system mounted on an O-arm rotating gantry for radiation therapy.
    Kim S; Lee YS; Kim GJ; Lee JH; Kim IS; Shin KY; Seol Y; Oh Y; Kang YN; Hwang J; Shin JS; Kim A; Kim J; Kim JI
    Rev Sci Instrum; 2021 Feb; 92(2):024103. PubMed ID: 33648097
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The measurement of linear accelerator isocenter motion using a three-micrometer device and an adjustable pointer.
    Tsai JS; Curran BH; Sternick ES; Engler MJ
    Int J Radiat Oncol Biol Phys; 1996 Jan; 34(1):189-95. PubMed ID: 12118550
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Clinical implementation of intensity-modulated arc therapy.
    Yu CX; Li XA; Ma L; Chen D; Naqvi S; Shepard D; Sarfaraz M; Holmes TW; Suntharalingam M; Mansfield CM
    Int J Radiat Oncol Biol Phys; 2002 Jun; 53(2):453-63. PubMed ID: 12023150
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Beam's-eye-view imaging during non-coplanar lung SBRT.
    Yip SS; Rottmann J; Berbeco RI
    Med Phys; 2015 Dec; 42(12):6776-83. PubMed ID: 26632035
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dynamic conical conformal radiotherapy using a C-arm-mounted accelerator: dose distribution and clinical application.
    Nakagawa K; Aoki Y; Tago M; Ohtomo K
    Int J Radiat Oncol Biol Phys; 2003 May; 56(1):287-95. PubMed ID: 12694850
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Mechanical quality assurance using light field for linear accelerators with camera calibration.
    Park K; Choi W; Keum KC; Lee H; Yoon J; Lee CG; Lee IJ; Cho J
    Phys Med; 2016 Feb; 32(2):398-402. PubMed ID: 26833362
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.