These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

187 related articles for article (PubMed ID: 9587864)

  • 1. Impact of prosthesis-patient mismatch on hemodynamic and symptomatic status, morbidity and mortality after aortic valve replacement with a bioprosthetic heart valve.
    Pibarot P; Dumesnil JG; Lemieux M; Cartier P; Métras J; Durand LG
    J Heart Valve Dis; 1998 Mar; 7(2):211-8. PubMed ID: 9587864
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The effect of prosthesis-patient mismatch on aortic bioprosthetic valve hemodynamic performance and patient clinical status.
    Pibarot P; Honos GN; Durand LG; Dumesnil JG
    Can J Cardiol; 1996 Apr; 12(4):379-87. PubMed ID: 8608457
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Influence of prosthesis-patient mismatch on diastolic heart failure after aortic valve replacement.
    Nozohoor S; Nilsson J; Lührs C; Roijer A; Sjögren J
    Ann Thorac Surg; 2008 Apr; 85(4):1310-7. PubMed ID: 18355517
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Influence of patient-prosthesis mismatch on long-term results after aortic valve replacement with a stented bioprosthesis.
    Frapier JM; Rouvière P; Razcka F; Aymard T; Albat B; Chaptal PA
    J Heart Valve Dis; 2002 Jul; 11(4):543-51. PubMed ID: 12150304
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comprehensive hemodynamic performance and frequency of patient-prosthesis mismatch of the St. Jude Medical Trifecta bioprosthetic aortic valve.
    Yadlapati A; Diep J; Barnes MJ; Grogan T; Bethencourt DM; Vorobiof G
    J Heart Valve Dis; 2014 Jul; 23(4):516-23. PubMed ID: 25803979
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Impact of valve prosthesis-patient mismatch on left ventricular mass regression following aortic valve replacement.
    Tasca G; Brunelli F; Cirillo M; DallaTomba M; Mhagna Z; Troise G; Quaini E
    Ann Thorac Surg; 2005 Feb; 79(2):505-10. PubMed ID: 15680824
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Patient-prosthesis mismatch has no influence on in-hospital mortality after aortic valve replacement.
    Yottasurodom C; Namthaisong K; Porapakkham P; Kasemsarn C; Chotivatanapong T; Chaiseri P; Wongdit S; Yasotarin S
    J Med Assoc Thai; 2012 Aug; 95 Suppl 8():S64-70. PubMed ID: 23130477
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The impact of patient-prosthesis mismatch on late outcomes after mitral valve replacement.
    Lam BK; Chan V; Hendry P; Ruel M; Masters R; Bedard P; Goldstein B; Rubens F; Mesana T
    J Thorac Cardiovasc Surg; 2007 Jun; 133(6):1464-73. PubMed ID: 17532940
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Prosthesis-Patient Mismatch After Aortic Valve Replacement: Effect on Long-Term Survival.
    Swinkels BM; de Mol BA; Kelder JC; Vermeulen FE; ten Berg JM
    Ann Thorac Surg; 2016 Apr; 101(4):1388-94. PubMed ID: 26921981
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Patient-prosthesis mismatch after small-size stentless aortic valve replacement.
    Gelsomino S; Morocutti G; Masullo G; Da Col P; Frassani R; Spedicato L; Livi U
    J Card Surg; 2004; 19(2):91-7. PubMed ID: 15016042
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Impact of prosthesis-patient mismatch on the quality of life of elderly patients after aortic valve replacement].
    Qian XM; Zhong SZ
    Nan Fang Yi Ke Da Xue Xue Bao; 2009 Oct; 29(10):2055-8, 2063. PubMed ID: 19861265
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Hemodynamic evaluation and midterm outcome of aortic valve replacement with size 19 Perimount prosthetic valve.
    Narayan P; Reeves BC; Rizvi SI; Shokrollahi K; Ismail H; Angelini GD; Nightingale A; Caputo M
    Ann Thorac Surg; 2008 Dec; 86(6):1799-803. PubMed ID: 19021980
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Late incidence and predictors of persistent or recurrent heart failure in patients with aortic prosthetic valves.
    Ruel M; Rubens FD; Masters RG; Pipe AL; Bédard P; Hendry PJ; Lam BK; Burwash IG; Goldstein WG; Brais MP; Keon WJ; Mesana TG
    J Thorac Cardiovasc Surg; 2004 Jan; 127(1):149-59. PubMed ID: 14752425
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Patient-prosthesis mismatch in patients undergoing bioprosthetic aortic valve implantation increases risk of reoperation for structural valve deterioration.
    Urso S; Calderón P; Sadaba R; Mahillo I; Tuñón J; Aldamiz G; Fraile J
    J Card Surg; 2014 Jul; 29(4):439-44. PubMed ID: 24773571
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Prosthesis-patient mismatch affects survival after aortic valve replacement.
    Rao V; Jamieson WR; Ivanov J; Armstrong S; David TE
    Circulation; 2000 Nov; 102(19 Suppl 3):III5-9. PubMed ID: 11082354
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of prosthesis-patient mismatch on long-term survival with aortic valve replacement: assessment to 15 years.
    Jamieson WR; Ye J; Higgins J; Cheung A; Fradet GJ; Skarsgard P; Germann E; Chan F; Lichtenstein SV
    Ann Thorac Surg; 2010 Jan; 89(1):51-8; discussion 59. PubMed ID: 20103205
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comprehensive hemodynamic comparison and frequency of patient-prosthesis mismatch between the St. Jude Medical Trifecta and Epic Bioprosthetic aortic valves.
    Yadlapati A; Diep J; Barnes M; Grogan T; Bethencourt DM; Vorobiof G
    J Am Soc Echocardiogr; 2014 Jun; 27(6):581-9. PubMed ID: 24534651
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Type and Size of Implanted Bioprosthetic Valve Rather Than Intraoperative Peak Transprosthetic Valvular Velocity Predict Postoperative Midterm Prosthesis-Patient Mismatch in Patients Undergoing Surgical Aortic Valve Replacement.
    Minami K; Kabata D; Shintani A; Matsumoto Y; Tadokoro N; Fujita T; Yoshitani K; Ohnishi Y
    J Cardiothorac Vasc Anesth; 2019 Dec; 33(12):3264-3270. PubMed ID: 31278007
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Prosthesis-patient mismatch after aortic valve replacement predominantly affects patients with preexisting left ventricular dysfunction: effect on survival, freedom from heart failure, and left ventricular mass regression.
    Ruel M; Al-Faleh H; Kulik A; Chan KL; Mesana TG; Burwash IG
    J Thorac Cardiovasc Surg; 2006 May; 131(5):1036-44. PubMed ID: 16678587
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Impact of valve prosthesis-patient mismatch estimated by echocardiographic-determined effective orifice area on long-term outcome after aortic valve replacement.
    Florath I; Albert A; Rosendahl U; Ennker IC; Ennker J
    Am Heart J; 2008 Jun; 155(6):1135-42. PubMed ID: 18513530
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.