416 related articles for article (PubMed ID: 9591865)
1. Comparison of concentric needle versus hooked-wire electrodes in the canine larynx.
Jaffe DM; Solomon NP; Robinson RA; Hoffman HT; Luschei ES
Otolaryngol Head Neck Surg; 1998 May; 118(5):655-62. PubMed ID: 9591865
[TBL] [Abstract][Full Text] [Related]
2. Spontaneous and evoked laryngeal electromyography of the thyroarytenoid muscles: a canine model for intraoperative recurrent laryngeal nerve monitoring.
Scott AR; Chong PS; Hartnick CJ; Randolph GW
Ann Otol Rhinol Laryngol; 2010 Jan; 119(1):54-63. PubMed ID: 20128189
[TBL] [Abstract][Full Text] [Related]
3. Development of a Closed-Loop Stimulator for Laryngeal Reanimation: Part 2. Device Testing in the Canine Model of Laryngeal Paralysis.
Heaton JT; Kobler JB; Otten DM; Hillman RE; Zeitels SM
Ann Otol Rhinol Laryngol; 2019 Mar; 128(3_suppl):53S-70S. PubMed ID: 30843434
[TBL] [Abstract][Full Text] [Related]
4. Correspondence between laryngeal vocal fold movement and muscle activity during speech and nonspeech gestures.
Poletto CJ; Verdun LP; Strominger R; Ludlow CL
J Appl Physiol (1985); 2004 Sep; 97(3):858-66. PubMed ID: 15133000
[TBL] [Abstract][Full Text] [Related]
5. Electromyography of the larynx and related technics.
Thumfart WF
Acta Otorhinolaryngol Belg; 1986; 40(2):358-76. PubMed ID: 3751530
[TBL] [Abstract][Full Text] [Related]
6. Bipolar hooked-wire electromyographic technique in the evaluation of pediatric vocal cord paralysis.
Gartlan MG; Peterson KL; Luschei ES; Hoffman HT; Smith RJ
Ann Otol Rhinol Laryngol; 1993 Sep; 102(9):695-700. PubMed ID: 8373093
[TBL] [Abstract][Full Text] [Related]
7. An implantable system for In Vivo chronic electromyographic study in the larynx.
Li Y; Huang S; Zealear D
Muscle Nerve; 2017 May; 55(5):706-714. PubMed ID: 27543847
[TBL] [Abstract][Full Text] [Related]
8. Functional Electrical Stimulation of the Feline Larynx With a Flexible Ribbon Electrode Array.
Bliss MR; Wark H; McDonnall D; Smith ME
Ann Otol Rhinol Laryngol; 2016 Feb; 125(2):130-6. PubMed ID: 26346278
[TBL] [Abstract][Full Text] [Related]
9. Relation of recurrent laryngeal nerve compound action potential to laryngeal biomechanics.
Nasri S; Dulguerov P; Damrose EJ; Ye M; Kreiman J; Berke GS
Laryngoscope; 1995 Jun; 105(6):639-43. PubMed ID: 7769950
[TBL] [Abstract][Full Text] [Related]
10. Serial electromyography of the thyroarytenoid muscles using the NIM-response system in a canine model of vocal fold paralysis.
Scott AR; Chong PS; Brigger MT; Randolph GW; Hartnick CJ
Ann Otol Rhinol Laryngol; 2009 Jan; 118(1):56-66. PubMed ID: 19244965
[TBL] [Abstract][Full Text] [Related]
11. [Electrode applicator for endolaryngeal electromyography of the larynx with local anesthesia].
Wolf SR
Laryngorhinootologie; 1995 Jul; 74(7):460-2. PubMed ID: 7669140
[TBL] [Abstract][Full Text] [Related]
12. "Facial" and standard concentric needle electrodes are not interchangeable.
Barkhaus PE; Roberts MM; Nandedkar SD
Electromyogr Clin Neurophysiol; 2006 Sep; 46(5):259-61. PubMed ID: 17059096
[TBL] [Abstract][Full Text] [Related]
13. The study of laryngeal muscle activity in normal human subjects and in patients with laryngeal dystonia using multiple fine-wire electromyography.
Hillel AD
Laryngoscope; 2001 Apr; 111(4 Pt 2 Suppl 97):1-47. PubMed ID: 11464801
[TBL] [Abstract][Full Text] [Related]
14. A Preclinical Study of Laryngeal Motor-Evoked Potentials as a Marker Vagus Nerve Activation.
Grimonprez A; Raedt R; De Taeye L; Larsen LE; Delbeke J; Boon P; Vonck K
Int J Neural Syst; 2015 Dec; 25(8):1550034. PubMed ID: 26510476
[TBL] [Abstract][Full Text] [Related]
15. Modulation of laryngeal responses to superior laryngeal nerve stimulation by volitional swallowing in awake humans.
Barkmeier JM; Bielamowicz S; Takeda N; Ludlow CL
J Neurophysiol; 2000 Mar; 83(3):1264-72. PubMed ID: 10712454
[TBL] [Abstract][Full Text] [Related]
16. Surface vs intramuscular laryngeal electromyography.
Hemmerling TM; Schmidt J; Wolf T; Wolf SR; Jacobi KE
Can J Anaesth; 2000 Sep; 47(9):860-5. PubMed ID: 10989855
[TBL] [Abstract][Full Text] [Related]
17. Development of a novel larynx pacemaker multichannel array electrode: In vivo animal analysis.
Faenger B; Schumann NP; Arnold D; Grassme R; Guntinas-Lichius O; Scholle HC
Laryngoscope; 2016 Feb; 126(2):429-36. PubMed ID: 26228845
[TBL] [Abstract][Full Text] [Related]
18. Compound Motor Action Potential Quantifies Recurrent Laryngeal Nerve Innervation in a Canine Model.
Bhatt NK; Park AM; Al-Lozi M; Paniello RC
Ann Otol Rhinol Laryngol; 2016 Jul; 125(7):584-90. PubMed ID: 26969454
[TBL] [Abstract][Full Text] [Related]
19. Peripheral component of laryngeal and pharyngeal motor evoked potentials.
Celik Gokyigit M; Ercan I; Seker S; Gundogdu Celebi L; Ertekin C
Neurophysiol Clin; 2016 Jun; 46(3):165-9. PubMed ID: 27318611
[TBL] [Abstract][Full Text] [Related]
20. Long-term model of induced canine phonation.
Paniello RC; Dahm JD
Otolaryngol Head Neck Surg; 1998 Apr; 118(4):512-22. PubMed ID: 9560104
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]