These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

155 related articles for article (PubMed ID: 9594900)

  • 1. An inexpensive method of heart stabilization during coronary artery operations without cardiopulmonary bypass.
    Lucchetti V; Angelini GD
    Ann Thorac Surg; 1998 May; 65(5):1477-8. PubMed ID: 9594900
    [TBL] [Abstract][Full Text] [Related]  

  • 2. "Single suture" for circumflex exposure in off-pump coronary artery bypass grafting.
    Bergsland J; Karamanoukian HL; Soltoski PR; Salerno TA
    Ann Thorac Surg; 1999 Oct; 68(4):1428-30. PubMed ID: 10543532
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A cost-effective retractor and heart stabilizer for minimal-access coronary bypass.
    Rousou JA; Engelman RM; Flack JE; Deaton DW
    Ann Thorac Surg; 1998 May; 65(5):1479-80. PubMed ID: 9594901
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A simple atraumatic clamp technique without a stabilizer in off-pump CABG: how to do it.
    Kucukarslan N; Arslan Y; Us MH; Yilmaz AT
    J Card Surg; 2005; 20(5):453-4. PubMed ID: 16153278
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Clamp for coronary artery operations.
    Walia AS; Kole SD
    Ann Thorac Surg; 1998 May; 65(5):1475-6. PubMed ID: 9594899
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Sharma's clamp for sequential coronary artery grafting.
    Sharma AK; Siddiqi MS; Al Sabti H
    Asian Cardiovasc Thorac Ann; 2015 Oct; 23(8):1007-9. PubMed ID: 25931571
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Off pump coronary bypass grafting of the circumflex artery.
    Pitsis AA; Angelini GD
    Eur J Cardiothorac Surg; 1999 Oct; 16(4):478-9. PubMed ID: 10571100
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A simple method for heart stabilization during off-pump multi-vessel coronary artery bypass grafting: surgical technique and short term results.
    Rama A; Mohammadi S; Leprince P; Gandjbakhch I
    Eur J Cardiothorac Surg; 2001 Jan; 19(1):105-7. PubMed ID: 11163574
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Hybrid-type stabilizer for off-pump direct coronary artery bypass grafting.
    Konishi T; Higuchi K; Fukata M; Akisima S; Fukuda S
    Ann Thorac Surg; 1998 Sep; 66(3):961-2. PubMed ID: 9768972
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Traction-type heart stabilizer for off-pump coronary bypass grafting.
    Morishita K; Komatsu K; Kuwaki K; Koshino T; Abe T
    Surg Today; 2001; 31(2):187-9. PubMed ID: 11291720
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Global myocardial revascularization without cardiopulmonary bypass using innovative techniques for myocardial stabilization and perfusion.
    Bedi HS; Suri A; Kalkat MS; Sengar BS; Mahajan V; Chawla R; Sharma VP
    Ann Thorac Surg; 2000 Jan; 69(1):156-64. PubMed ID: 10654506
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Mini-sternotomy for coronary artery bypass grafting.
    Arom KV; Emery RW; Nicoloff DM
    Ann Thorac Surg; 1996 Apr; 61(4):1271-2. PubMed ID: 8607708
    [TBL] [Abstract][Full Text] [Related]  

  • 13. New anastomosis assist devices for coronary artery bypass grafting.
    Shimamura Y; Takemura T; Agematsu K
    Asian Cardiovasc Thorac Ann; 2006 Feb; 14(1):72-4. PubMed ID: 16432126
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Clinical use of a computer-enhanced surgical robotic system for endoscopic coronary artery bypass grafting on the beating heart.
    Boehm DH; Reichenspurner H; Detter C; Arnold M; Gulbins H; Meiser B; Reichart B
    Thorac Cardiovasc Surg; 2000 Aug; 48(4):198-202. PubMed ID: 11005592
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The C-Port Distal Coronary Anastomotic Device Is Comparable With a Hand-Sewn Anastomosis: Human Histological Case Study.
    Balkhy HH; Nisivaco SM; Husain AN; Jeevanandam V; Arif Q
    Innovations (Phila); 2018; 13(2):140-143. PubMed ID: 29688941
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Initial experience using an intraluminal shunt during revascularization of the beating heart.
    Rivetti LA; Gandra SM
    Ann Thorac Surg; 1997 Jun; 63(6):1742-7. PubMed ID: 9205177
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Sutured coronary artery grafting utilizing the Heartflo anastomosis device--first clinical experiences.
    Martens S; Doss M; Moritz A; Wimmer-Greinecker G
    Thorac Cardiovasc Surg; 2002 Feb; 50(1):1-4. PubMed ID: 11847595
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Techniques of exposure and stabilization in off-pump coronary artery bypass graft.
    Soltoski P; Bergsland J; Salerno TA; Karamanoukian HL; D'Ancona G; Ricci M; Panos AL
    J Card Surg; 1999; 14(5):392-400. PubMed ID: 10875598
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Pulmonary abnormalities after coronary arterial bypass grafting operation: cardiopulmonary bypass versus mechanical stabilization.
    Kochamba GS; Yun KL; Pfeffer TA; Sintek CF; Khonsari S
    Ann Thorac Surg; 2000 May; 69(5):1466-70. PubMed ID: 10881824
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Off-pump multivessel coronary artery bypass utilizing the Octopus tissue stabilization system: initial experience in 374 patients from three separate centers.
    Hart JC; Spooner T; Edgerton J; Milsteen SA
    Heart Surg Forum; 1999; 2(1):15-28. PubMed ID: 11276456
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.