These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 9597731)

  • 1. A piezoelectric quartz crystal sensor for the determination of coagulation time in plasma and whole blood.
    Cheng TJ; Chang HC; Lin TM
    Biosens Bioelectron; 1998 Feb; 13(2):147-56. PubMed ID: 9597731
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Detection of fibrinogen and coagulation factor VIII in plasma by a quartz crystal microbalance biosensor.
    Yao C; Qu L; Fu W
    Sensors (Basel); 2013 May; 13(6):6946-56. PubMed ID: 23708275
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A quartz crystal viscosity sensor for monitoring coagulation reaction and its application to a multichannel coagulation detector.
    Muramatsu H; Kimura K; Ataka T; Homma R; Miura Y; Karube I
    Biosens Bioelectron; 1991; 6(4):353-8. PubMed ID: 1909147
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Investigation of prothrombin time in human whole-blood samples with a quartz crystal biosensor.
    Müller L; Sinn S; Drechsel H; Ziegler C; Wendel HP; Northoff H; Gehring FK
    Anal Chem; 2010 Jan; 82(2):658-63. PubMed ID: 20000697
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Performance Enhancement of Interdigital Electrode-Piezoelectric Quartz Crystal (IDE-PQC) Salt Concentration Sensor by Increasing the Electrode Area of Piezoelectric Quartz Crystal (PQC).
    Zhang H; Yao Y; Shi Y
    Sensors (Basel); 2018 Sep; 18(10):. PubMed ID: 30257463
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Design and evaluation of a portable optical-based biosensor for testing whole blood prothrombin time.
    Yang CL; Huang SJ; Chou CW; Chiou YC; Lin KP; Tsai MS; Young KC
    Talanta; 2013 Nov; 116():704-11. PubMed ID: 24148464
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Enantioselective piezoelectric quartz crystal sensor for d-methamphetamine based on a molecularly imprinted polymer.
    Arenas LF; Ebarvia BS; Sevilla FB
    Anal Bioanal Chem; 2010 Aug; 397(7):3155-8. PubMed ID: 20526767
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Immobilization of bovine serum albumin as a sensitive biosensor for the detection of trace lead ion in solution by piezoelectric quartz crystal impedance.
    Yin J; Wei W; Liu X; Kong B; Wu L; Gong S
    Anal Biochem; 2007 Jan; 360(1):99-104. PubMed ID: 17097591
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Blood Coagulation Testing Smartphone Platform Using Quartz Crystal Microbalance Dissipation Method.
    Yao J; Feng B; Zhang Z; Li C; Zhang W; Guo Z; Zhao H; Zhou L
    Sensors (Basel); 2018 Sep; 18(9):. PubMed ID: 30217015
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Clinical evaluation of whole blood prothrombin time (PT) and international normalized ratio (INR) using a Laser Speckle Rheology sensor.
    Tripathi MM; Egawa S; Wirth AG; Tshikudi DM; Van Cott EM; Nadkarni SK
    Sci Rep; 2017 Aug; 7(1):9169. PubMed ID: 28835607
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Utilisation of Quartz Crystal Microbalance Sensors with Dissipation (QCM-D) for a Clauss Fibrinogen Assay in Comparison with Common Coagulation Reference Methods.
    Oberfrank S; Drechsel H; Sinn S; Northoff H; Gehring FK
    Sensors (Basel); 2016 Feb; 16(3):282. PubMed ID: 26927107
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Coagulation Testing in the Core Laboratory.
    Winter WE; Flax SD; Harris NS
    Lab Med; 2017 Nov; 48(4):295-313. PubMed ID: 29126301
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Micro-electromechanical film bulk acoustic sensor for plasma and whole blood coagulation monitoring.
    Chen D; Song S; Ma J; Zhang Z; Wang P; Liu W; Guo Q
    Biosens Bioelectron; 2017 May; 91():465-471. PubMed ID: 28068607
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Quartz-crystal sensors for biosensing and chemical analysis.
    Muramatsu H; Kim JM; Chang SM
    Anal Bioanal Chem; 2002 Jan; 372(2):314-21. PubMed ID: 11936105
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of surface plasmon resonance and quartz crystal microbalance in the study of whole blood and plasma coagulation.
    Vikinge TP; Hansson KM; Sandström P; Liedberg B; Lindahl TL; Lundström I; Tengvall P; Höök F
    Biosens Bioelectron; 2000; 15(11-12):605-13. PubMed ID: 11213221
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Piezoelectric quartz crystal sensor for rapid analysis of pirimicarb residues using molecularly imprinted polymers as recognition elements.
    Sun H; Fung Y
    Anal Chim Acta; 2006 Aug; 576(1):67-76. PubMed ID: 17723616
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of a point-of-care coagulation analyzer for measurement of prothrombin time, activated partial thromboplastin time, and activated clotting time in dogs.
    Tseng LW; Hughes D; Giger U
    Am J Vet Res; 2001 Sep; 62(9):1455-60. PubMed ID: 11560277
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Surface plasmon resonance (SPR) analysis of coagulation in whole blood with application in prothrombin time assay.
    Hansson KM; Vikinge TP; Rånby M; Tengvall P; Lundström I; Johansen K; Lindahl TL
    Biosens Bioelectron; 1999 Dec; 14(8-9):671-82. PubMed ID: 10641287
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of lipoprotein-associated coagulation inhibitor (LACI) on thromboplastin-induced coagulation of normal and hemophiliac plasmas.
    Welsch DJ; Novotny WF; Wun TC
    Thromb Res; 1991 Oct; 64(2):213-22. PubMed ID: 1811340
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Electrochemical piezoelectric quartz crystal impedance study on the interaction between concanavalin A and glycogen at Au electrodes.
    Tan L; Xie Q; Yao S
    Bioelectrochemistry; 2007 May; 70(2):348-55. PubMed ID: 16809074
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.