These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
69 related articles for article (PubMed ID: 9598265)
1. An evaluation of a modified Macintosh laryngoscope in a manikin. Bucx MJ; Snijders CJ; van der Vegt MH; Stijnen T Can J Anaesth; 1998 May; 45(5 Pt 1):483-7. PubMed ID: 9598265 [TBL] [Abstract][Full Text] [Related]
2. Reshaping the Macintosh blade using biomechanical modelling. A prospective comparative study in patients. Bucx MJ; Snijders CJ; ven der Vegt MH; Holstein JD; Stijnen T Anaesthesia; 1997 Jul; 52(7):662-7. PubMed ID: 9244026 [TBL] [Abstract][Full Text] [Related]
3. A comparison of the Laryngopharyngeal Examination blade and the English Macintosh laryngoscope blade using an intubating manikin: a prospective randomized crossover study. Ashfaque M; Mason J; Al-Shaikh B; Adegoke K Eur J Anaesthesiol; 2009 Nov; 26(11):917-22. PubMed ID: 19593148 [TBL] [Abstract][Full Text] [Related]
4. The Callander laryngoscope blade modification is associated with a decreased risk of dental contact. Lee J; Choi JH; Lee YK; Kim ES; Kwon OK; Hastings RH Can J Anaesth; 2004 Feb; 51(2):181-4. PubMed ID: 14766698 [TBL] [Abstract][Full Text] [Related]
5. Forces applied to the maxillary incisors during video-assisted intubation. Lee RA; van Zundert AA; Maassen RL; Willems RJ; Beeke LP; Schaaper JN; van Dobbelsteen J; Wieringa PA Anesth Analg; 2009 Jan; 108(1):187-91. PubMed ID: 19095848 [TBL] [Abstract][Full Text] [Related]
6. The usefulness of the modified laryngoscopic blade for training novice laryngoscopists. Lee J; Kim BS; Chang HW; Lee Y J Clin Anesth; 2005 Aug; 17(5):334-8. PubMed ID: 16102681 [TBL] [Abstract][Full Text] [Related]
7. The Callender modification of the Macintosh laryngoscope blade reduces the risk of tooth-blade contact in children. Mireskandari SM; Askarizadeh N; Darabi ME; Rahimi E; Ataee HA; Chamrami F; Eghtesadi-Araghi P Paediatr Anaesth; 2008 Nov; 18(11):1035-9. PubMed ID: 18950325 [TBL] [Abstract][Full Text] [Related]
8. Evaluation of the new Viewmax laryngoscope in a simulated difficult airway. Leung YY; Hung CT; Tan ST Acta Anaesthesiol Scand; 2006 May; 50(5):562-7. PubMed ID: 16643225 [TBL] [Abstract][Full Text] [Related]
10. Evaluation of new laryngoscope blade for tracheal intubation, Truview EVO2: a manikin study. Miceli L; Cecconi M; Tripi G; Zauli M; Della Rocca G Eur J Anaesthesiol; 2008 Jun; 25(6):446-9. PubMed ID: 18294407 [TBL] [Abstract][Full Text] [Related]
11. Airway Scope versus Macintosh laryngoscope: a manikin study. Hirabayashi Y Emerg Med J; 2007 May; 24(5):357-8. PubMed ID: 17452706 [TBL] [Abstract][Full Text] [Related]
12. Evaluation of the Airway Scope, a new video laryngoscope, in tracheal intubation by naive operators: a manikin study. Miki T; Inagawa G; Kikuchi T; Koyama Y; Goto T Acta Anaesthesiol Scand; 2007 Nov; 51(10):1378-81. PubMed ID: 17944642 [TBL] [Abstract][Full Text] [Related]
13. Does experience influence the forces exerted on maxillary incisors during laryngoscopy? A manikin study using the Macintosh laryngoscope. Bucx MJ; van Geel RT; Wegener JT; Robers C; Stijnen T Can J Anaesth; 1995 Feb; 42(2):144-9. PubMed ID: 7720158 [TBL] [Abstract][Full Text] [Related]
14. Effects of a suction laryngoscope in a model with simulated severe airway hemorrhage. Mitterlechner T; Nerbl N; Herff H; Paal P; Moritz M; Kloss F; Lindner KH; Wenzel V Anesth Analg; 2008 May; 106(5):1505-8, table of contents. PubMed ID: 18420868 [TBL] [Abstract][Full Text] [Related]
15. [Determination of the distance between the upper incisors and the laryngoscope blade during laryngoscopy: comparisons of the McCoy, the Macintosh, the Miller, and the Belscope blades]. Bito H; Nishiyama T; Higarhizawa T; Sakai T; Konishi A Masui; 1998 Oct; 47(10):1257-61. PubMed ID: 9834604 [TBL] [Abstract][Full Text] [Related]
16. [A modified Macintosh blade with an angulated tip for difficult intubations]. Scherer R; Habel G Anasth Intensivther Notfallmed; 1990 Dec; 25(6):432-5. PubMed ID: 2281854 [TBL] [Abstract][Full Text] [Related]
17. A comparison of the Glidescope, Pentax AWS, and Macintosh laryngoscopes when used by novice personnel: a manikin study. Malik MA; Hassett P; Carney J; Higgins BD; Harte BH; Laffey JG Can J Anaesth; 2009 Nov; 56(11):802-11. PubMed ID: 19655213 [TBL] [Abstract][Full Text] [Related]
18. A randomised, crossover study of the Dorges, McCoy and Macintosh laryngoscope blades in a simulated difficult intubation scenario. Sethuraman D; Darshane S; Guha A; Charters P Anaesthesia; 2006 May; 61(5):482-7. PubMed ID: 16674625 [TBL] [Abstract][Full Text] [Related]
19. A simple fibreoptic assisted laryngoscope for paediatric difficult intubation: a manikin study. Komiya K; Inagawa G; Nakamura K; Kikuchi T; Fujimoto J; Sugawara Y; Goto T Anaesthesia; 2009 Apr; 64(4):425-9. PubMed ID: 19317709 [TBL] [Abstract][Full Text] [Related]
20. A clinical comparison of the Flexiblade and Macintosh laryngoscopes for laryngeal exposure in anesthetized adults. Cheung RW; Irwin MG; Law BC; Chan CK Anesth Analg; 2006 Feb; 102(2):626-30. PubMed ID: 16428574 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]