These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

155 related articles for article (PubMed ID: 9600533)

  • 1. Distal coronary artery perforation resulting from the use of hydrophilic coated guidewire in tortuous vessels.
    Wong CM; Kwong Mak GY; Chung DT
    Cathet Cardiovasc Diagn; 1998 May; 44(1):93-6. PubMed ID: 9600533
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Gelfoam embolization of a distal coronary artery guidewire perforation.
    Dixon SR; Webster MW; Ormiston JA; Wattie WJ; Hammett CJ
    Catheter Cardiovasc Interv; 2000 Feb; 49(2):214-7. PubMed ID: 10642778
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Successful treatment of coronary artery perforation during angioplasty using autologous vein graft-coated stent.
    Chae JK; Park SW; Kim YH; Hong MK; Park SJ
    Eur Heart J; 1997 Jun; 18(6):1030-2. PubMed ID: 9183598
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A word of caution on optimizing stent deployment in calcified lesions: acute coronary rupture with cardiac tamponade.
    Reimers B; von Birgelen C; van der Giessen WJ; Serruys PW
    Am Heart J; 1996 Jan; 131(1):192-4. PubMed ID: 8554008
    [No Abstract]   [Full Text] [Related]  

  • 5. Fracture of coronary guidewire during rotational atherectomy with coronary perforation and tamponade.
    Woodfield SL; Lopez A; Heuser RR
    Cathet Cardiovasc Diagn; 1998 Jun; 44(2):220-3. PubMed ID: 9637449
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Management of coronary perforation after percutaneous balloon angioplasty with a new membrane stent].
    Welge D; Haude M; von Birgelen C; Liu F; Altmann C; Ge J; Erbel R
    Z Kardiol; 1998 Dec; 87(12):948-53. PubMed ID: 10025067
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Retrieval of undeployed stents from the right coronary artery: report of two cases.
    Veldhuijzen FL; Bonnier HJ; Michels HR; el Gamal MI; van Gelder BM
    Cathet Cardiovasc Diagn; 1993 Nov; 30(3):245-8. PubMed ID: 8269498
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Successful collapse vessel treatment with a syringe for thrombus-aspiration after the guidewire-induced coronary artery perforation.
    Yasuoka Y; Sasaki T
    Cardiovasc Revasc Med; 2010; 11(4):263.e1-3. PubMed ID: 20934662
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Bypass perforation by stent implantation: complication management. A case report].
    Michael A; Solzbach U; Saurbier B; Schmidt-Schweda S; Schöllhorn J; Beyersdorf F; Just H; Holubarsch C
    Z Kardiol; 1998 Mar; 87(3):233-9. PubMed ID: 9586159
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Recanalization of chronic coronary occlusions using a new hydrophilic guidewire.
    Corcos T; Favereau X; Guérin Y; Toussaint M; Ouzan J; Zheng H; Pentousis D
    Cathet Cardiovasc Diagn; 1998 May; 44(1):83-90. PubMed ID: 9600531
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Mechanical recanalization of total coronary occlusions with the use of a new guide wire.
    Reimers B; Camassa N; Di Mario C; Akiyama T; Di Francesco L; Finci L; Colombo A
    Am Heart J; 1998 Apr; 135(4):726-31. PubMed ID: 9539493
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A unique complication of the retrograde approach in angioplasty for chronic total occlusion of the coronary artery.
    Matsumi J; Adachi K; Saito S
    Catheter Cardiovasc Interv; 2008 Sep; 72(3):371-378. PubMed ID: 18727117
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Cardiac perforation complicated by cardiac tamponade and sealed with metallic coils].
    Martí V; Castaño C; Guiteras P; Vallés E; Domínguez de Rozas JM; Augé JM
    Rev Esp Cardiol; 2004 Oct; 57(10):990-2. PubMed ID: 15469797
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Recurrent cardiac tamponade following unusual micro leak after successful closure of the primary leak.
    Baruah DK; Lakshmi A; Chandrashekaran V
    J Invasive Cardiol; 2012 Mar; 24(3):E47-9. PubMed ID: 22388314
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Delayed and recurrent cardiac tamponade following distal coronary perforation of hydrphilic guidewires during coronary intervention.
    De Marco F; Balcells J; Lefèvre T; Routledge H; Louvard Y; Morice MC
    J Invasive Cardiol; 2008 May; 20(5):E150-3. PubMed ID: 18460717
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Guidewire-induced coronary artery perforation and tamponade during PCI: in-hospital outcomes and impact on long-term survival.
    Stathopoulos I; Panagopoulos G; Kossidas K; Jimenez M; Garratt K
    J Invasive Cardiol; 2014 Aug; 26(8):371-6. PubMed ID: 25091096
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Coronary perforation and tamponade during thrombectomy and treatment with PTFE coated stent and autotransfusion: a case report.
    Bilge AK; Nişanci Y; Ozben B; Yilmaz E; Umman B
    Anadolu Kardiyol Derg; 2003 Jun; 3(2):174-6. PubMed ID: 12826515
    [No Abstract]   [Full Text] [Related]  

  • 18. Acute and long-term outcome after coronary artery perforation during percutaneous coronary interventions.
    Eggebrecht H; Ritzel A; von Birgelen C; Schermund A; Naber C; Böse D; Baumgart D; Bartel T; Haude M; Erbel R
    Z Kardiol; 2004 Oct; 93(10):791-8. PubMed ID: 15492894
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Successful management of osteal perforation of left anterior descending artery with coated stent.
    Yilmaz H; Demir I; Sancaktar O; Basarici I
    Int J Cardiol; 2003 Apr; 88(2-3):293-6. PubMed ID: 12714210
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Cardiac tamponade following coronary arterial rupture during coronary angioplasty.
    Nassar H; Hasin Y; Gotsman MS
    Cathet Cardiovasc Diagn; 1991 Jul; 23(3):177-9. PubMed ID: 1868528
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.