These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 9604579)

  • 1. 3D-FEA of osseointegration percentages and patterns on implant-bone interfacial stresses.
    Papavasiliou G; Kamposiora P; Bayne SC; Felton DA
    J Dent; 1997 Nov; 25(6):485-91. PubMed ID: 9604579
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Influence of percentage of osseointegration on stress distribution around dental implants.
    Lai H; Zhang F; Zhang B; Yang C; Xue M
    Chin J Dent Res; 1998 Dec; 1(3):7-11. PubMed ID: 10557165
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of diameter and length on stress distribution of the alveolar crest around immediate loading implants.
    Ding X; Liao SH; Zhu XH; Zhang XH; Zhang L
    Clin Implant Dent Relat Res; 2009 Dec; 11(4):279-87. PubMed ID: 18783411
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The staggered installation of dental implants and its effect on bone stresses.
    Abu-Hammad O; Khraisat A; Dar-Odeh N; Jagger DC; Hammerle CH
    Clin Implant Dent Relat Res; 2007 Sep; 9(3):121-7. PubMed ID: 17716255
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Three-dimensional finite element stress analysis in and around the Screw-Vent implant.
    Clelland NL; Ismail YH; Zaki HS; Pipko D
    Int J Oral Maxillofac Implants; 1991; 6(4):391-8. PubMed ID: 1820307
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Guidelines for analysis and redesign of dental implants.
    Patra AK; DePaolo JM; D'Souza KS; DeTolla D; Meenaghan MA
    Implant Dent; 1998; 7(4):355-68. PubMed ID: 10196813
    [TBL] [Abstract][Full Text] [Related]  

  • 7. FEA of Peri-Implant Stresses in Fixed Partial Denture Prostheses with Cantilevers.
    Alencar SM; Nogueira LB; Leal de Moura W; Rubo JH; Saymo de Oliveira Silva T; Martins GA; Moura CD
    J Prosthodont; 2017 Feb; 26(2):150-155. PubMed ID: 26588042
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of the cylinder implant thread height and width: a 3-dimensional finite element analysis.
    Kong L; Hu K; Li D; Song Y; Yang J; Wu Z; Liu B
    Int J Oral Maxillofac Implants; 2008; 23(1):65-74. PubMed ID: 18416414
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The influence of implant diameter and length on stress distribution of osseointegrated implants related to crestal bone geometry: a three-dimensional finite element analysis.
    Baggi L; Cappelloni I; Di Girolamo M; Maceri F; Vairo G
    J Prosthet Dent; 2008 Dec; 100(6):422-31. PubMed ID: 19033026
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of Platform Switching on Crestal Bone Stress in Tapered and Cylindrical Implants: A Finite Element Analysis.
    Rasouli-Ghahroudi AA; Geramy A; Yaghobee S; Khorsand A; Yousefifakhr H; Rokn A; Soolari A
    J Int Acad Periodontol; 2015 Jan; 17(1):2-13. PubMed ID: 26233968
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Finite element analysis of peri-implant bone volume affected by stresses around Morse taper implants: effects of implant positioning to the bone crest.
    Macedo JP; Pereira J; Faria J; Souza JCM; Alves JL; López-López J; Henriques B
    Comput Methods Biomech Biomed Engin; 2018 Sep; 21(12):655-662. PubMed ID: 30693810
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effects of implant length and diameter prior to and after osseointegration: a 2-D finite element analysis.
    Georgiopoulos B; Kalioras K; Provatidis C; Manda M; Koidis P
    J Oral Implantol; 2007; 33(5):243-56. PubMed ID: 17987856
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The Influence of Bone Quality on the Biomechanical Behavior of a Tooth-Implant Fixed Partial Denture: A Three-Dimensional Finite Element Analysis.
    Tsouknidas A; Giannopoulos D; Savvakis S; Michailidis N; Lympoudi E; Fytanidis D; Pissiotis A; Michalakis K
    Int J Oral Maxillofac Implants; 2016; 31(6):e143-e154. PubMed ID: 27861651
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Magnitude and direction of mechanical stress at the osseointegrated interface of the microthread implant.
    Hudieb MI; Wakabayashi N; Kasugai S
    J Periodontol; 2011 Jul; 82(7):1061-70. PubMed ID: 21189091
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of stress pattern generated through various thread designs of dental implants loaded in a condition of immediately after placement and on osseointegration--an FEA study.
    Chowdhary R; Halldin A; Jimbo R; Wennerberg A
    Implant Dent; 2013 Feb; 22(1):91-6. PubMed ID: 23287982
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A finite element analysis of two different dental implants: stress distribution in the prosthesis, abutment, implant, and supporting bone.
    Quaresma SE; Cury PR; Sendyk WR; Sendyk C
    J Oral Implantol; 2008; 34(1):1-6. PubMed ID: 18390236
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effects of different fixture geometries on the stress distribution in mandibular peri-implant structures: a 3-dimensional finite element analysis.
    Degerliyurt K; Simsek B; Erkmen E; Eser A
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2010 Aug; 110(2):e1-11. PubMed ID: 20598590
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of stress transmission in the IMZ implant system with polyoxymethylene or titanium intramobile element: a finite element stress analysis.
    Holmes DC; Grigsby WR; Goel VK; Keller JC
    Int J Oral Maxillofac Implants; 1992; 7(4):450-8. PubMed ID: 1299640
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Influence of tapered and external hexagon connections on bone stresses around tilted dental implants: three-dimensional finite element method with statistical analysis.
    de Faria Almeida DA; Pellizzer EP; Verri FR; Santiago JF; de Carvalho PS
    J Periodontol; 2014 Feb; 85(2):261-9. PubMed ID: 23688104
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Bone adaptation induced by non-passively fitting implant superstructures: a finite element analysis based on in vivo strain measurements.
    Winter W; Taylor TD; Karl M
    Int J Oral Maxillofac Implants; 2011; 26(6):1288-95. PubMed ID: 22167435
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.