These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

101 related articles for article (PubMed ID: 9608476)

  • 1. A generic off-axis energy correction for linac photon beam dosimetry.
    Tailor RC; Tello VM; Schroy CB; Vossler M; Hanson WF
    Med Phys; 1998 May; 25(5):662-7. PubMed ID: 9608476
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Photon beam quality variations of a flattening filter free linear accelerator.
    Georg D; Kragl G; Wetterstedt Sa; McCavana P; McClean B; Knöös T
    Med Phys; 2010 Jan; 37(1):49-53. PubMed ID: 20175465
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Modelling lateral beam quality variations in pencil kernel based photon dose calculations.
    Nyholm T; Olofsson J; Ahnesjö A; Karlsson M
    Phys Med Biol; 2006 Aug; 51(16):4111-8. PubMed ID: 16885628
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Monte Carlo study of in-field and out-of-field dose distributions from a linear accelerator operating with and without a flattening-filter.
    Almberg SS; Frengen J; Lindmo T
    Med Phys; 2012 Aug; 39(8):5194-203. PubMed ID: 22894444
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Combining tissue-phantom ratios to provide a beam-quality specifier for flattening filter free photon beams.
    Dalaryd M; Knöös T; Ceberg C
    Med Phys; 2014 Nov; 41(11):111716. PubMed ID: 25370630
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Monitor unit calculation on the beam axis of open and wedged asymmetric high-energy photon beams.
    Georg D
    Phys Med Biol; 1999 Dec; 44(12):2987-3007. PubMed ID: 10616150
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Reference photon dosimetry data and reference phase space data for the 6 MV photon beam from varian clinac 2100 series linear accelerators.
    Cho SH; Vassiliev ON; Lee S; Liu HH; Ibbott GS; Mohan R
    Med Phys; 2005 Jan; 32(1):137-48. PubMed ID: 15719964
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Calculation of photon energy and dose distributions in a 50 MV scanned photon beam for different target configurations and scan patterns.
    Sätherberg A; Karlsson M
    Med Phys; 1998 Feb; 25(2):236-40. PubMed ID: 9507485
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Experimental investigation of the response of an amorphous silicon EPID to intensity modulated radiotherapy beams.
    Greer PB; Vial P; Oliver L; Baldock C
    Med Phys; 2007 Nov; 34(11):4389-98. PubMed ID: 18072504
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Experimental investigation of the response of an a-Si EPID to an unflattened photon beam from an Elekta Precise linear accelerator.
    Tyner E; McClean B; McCavana P; af Wetterstedt S
    Med Phys; 2009 Apr; 36(4):1318-29. PubMed ID: 19472639
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Beam modeling and verification of a photon beam multisource model.
    Ahnesjö A; Weber L; Murman A; Saxner M; Thorslund I; Traneus E
    Med Phys; 2005 Jun; 32(6):1722-37. PubMed ID: 16013730
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Calculative technique to correct for the change in linear accelerator beam energy at off-axis points.
    Hanson WF; Berkley LW; Peterson M
    Med Phys; 1980; 7(2):147-50. PubMed ID: 6770241
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Characteristics of flattening filter free beams at low monitor unit settings.
    Akino Y; Ota S; Inoue S; Mizuno H; Sumida I; Yoshioka Y; Isohashi F; Ogawa K
    Med Phys; 2013 Nov; 40(11):112101. PubMed ID: 24320454
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Peripheral dose from a linear accelerator equipped with multileaf collimation.
    Stern RL
    Med Phys; 1999 Apr; 26(4):559-63. PubMed ID: 10227359
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Design of a fast multileaf collimator for radiobiological optimized IMRT with scanned beams of photons, electrons, and light ions.
    Svensson R; Larsson S; Gudowska I; Holmberg R; Brahme A
    Med Phys; 2007 Mar; 34(3):877-88. PubMed ID: 17441233
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Photon spectral characteristics of dissimilar 6 MV linear accelerators.
    Hinson WH; Kearns WT; deGuzman AF; Bourland JD
    Med Phys; 2008 May; 35(5):1698-702. PubMed ID: 18561644
    [TBL] [Abstract][Full Text] [Related]  

  • 17. On-axis and off-axis primary dose component in high energy photon beams.
    Zefkili S; Kappas C; Rosenwald JC
    Med Phys; 1994 Jun; 21(6):799-808. PubMed ID: 7935217
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A simple method of obtaining off-axis half-value layers for megavoltage photon beams.
    Barish RJ
    Med Phys; 1995 Sep; 22(9):1467-8. PubMed ID: 8531874
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Optimization of photon beam flatness for radiation therapy.
    Olofsson J; Nyholm T; Ahnesjö A; Karlsson M
    Phys Med Biol; 2007 Mar; 52(6):1735-46. PubMed ID: 17327659
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Linear accelerator photon beam quality at off-axis points.
    Yu MK; Sloboda RS; Murray B
    Med Phys; 1997 Feb; 24(2):233-9. PubMed ID: 9048363
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.