These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
144 related articles for article (PubMed ID: 9608483)
1. Evaluation of a new sealed reentrant well chamber for HDR and LDR brachytherapy calibrations. Pai S; Reinstein LE Med Phys; 1998 May; 25(5):719-21. PubMed ID: 9608483 [TBL] [Abstract][Full Text] [Related]
2. A parallel plate chamber for calibration of 192Ir LDR and HDR sources. Das KR; Kenny MB Med Phys; 1999 Nov; 26(11):2438-40. PubMed ID: 10587229 [TBL] [Abstract][Full Text] [Related]
3. The design of a new insert for calibration of LDR and HDR 192Ir sources in a well-type ionization chamber. Pineda AE; Alcón EP; deAlmeida CE Med Phys; 2003 Jul; 30(7):1566-8. PubMed ID: 12906174 [TBL] [Abstract][Full Text] [Related]
4. A radiation quality correction factor k for well-type ionization chambers for the measurement of the reference air kerma rate of (60)Co HDR brachytherapy sources. Schüller A; Meier M; Selbach HJ; Ankerhold U Med Phys; 2015 Jul; 42(7):4285-94. PubMed ID: 26133626 [TBL] [Abstract][Full Text] [Related]
6. Determination of absorbed dose in water at the reference point d(r0, theta0) for an 192Ir HDR brachytherapy source using a Fricke system. Austerlitz C; Mota HC; Sempau J; Benhabib SM; Campos D; Allison R; DeAlmeida CE; Zhu D; Sibata CH Med Phys; 2008 Dec; 35(12):5360-5. PubMed ID: 19175095 [TBL] [Abstract][Full Text] [Related]
7. On the stability of well-type ionization chamber source strength calibration coefficients. Smith BR; DeWerd LA; Culberson WS Med Phys; 2020 Sep; 47(9):4491-4501. PubMed ID: 32434273 [TBL] [Abstract][Full Text] [Related]
8. In-air calibration of an HDR 192Ir brachytherapy source using therapy ion chambers. Patel NP; Majumdar B; Vijiyan V; Hota PK J Cancer Res Ther; 2005; 1(4):213-20. PubMed ID: 17998656 [TBL] [Abstract][Full Text] [Related]
9. Study of scattered radiation for in-air calibration by a multiple-distance method using ionization chambers and an HDR 192Ir brachytherapy source. Patel NP; Majumdar B; Vijayan V Br J Radiol; 2006 Apr; 79(940):347-52. PubMed ID: 16585730 [TBL] [Abstract][Full Text] [Related]
10. Evaluation of a well-type ionization chamber for calibration of HDL and LDR brachytherapy sources. Ho AK; Sibata CH; deSouza CN; Castiglione R; Shin KH Med Dosim; 1995; 20(1):31-4. PubMed ID: 7794488 [TBL] [Abstract][Full Text] [Related]
12. A BrachyPhantom for verification of dose calculation of HDR brachytherapy planning system. Austerlitz C; Campos CA Med Phys; 2013 Nov; 40(11):112103. PubMed ID: 24320456 [TBL] [Abstract][Full Text] [Related]
13. Monte Carlo calculations of the ionization chamber wall correction factors for 192Ir and 60Co gamma rays and 250 kV x-rays for use in calibration of 192Ir HDR brachytherapy sources. Ferreira IH; de Almeida CE; Marre D; Marechal MH; Bridier A; Chavaudra J Phys Med Biol; 1999 Aug; 44(8):1897-904. PubMed ID: 10473203 [TBL] [Abstract][Full Text] [Related]
14. Evaluation of scatter contribution and distance error by iterative methods for strength determination of HDR 192Ir brachytherapy source. Kumar S; Srinivasan P; Sharma SD; Subbaiah KV; Mayya YS Med Dosim; 2010; 35(3):230-7. PubMed ID: 19931038 [TBL] [Abstract][Full Text] [Related]
15. Replacement corrections of a Farmer-type ionization chamber for the calibration of Cs-137 and Ir-192 sources in a solid phantom. Steggerda MJ; Mijnheer BJ Radiother Oncol; 1994 Apr; 31(1):76-84. PubMed ID: 8041900 [TBL] [Abstract][Full Text] [Related]
16. Air-kerma strength determination of a 169Yb high dose rate brachytherapy source. VanDamme JJ; Culberson WS; DeWerd LA; Micka JA Med Phys; 2008 Sep; 35(9):3935-42. PubMed ID: 18841844 [TBL] [Abstract][Full Text] [Related]
17. Applications of the Italian protocol for the calibration of brachytherapy sources. Piermattei A; Azario L Phys Med Biol; 1997 Aug; 42(8):1661-9. PubMed ID: 9279913 [TBL] [Abstract][Full Text] [Related]