These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

144 related articles for article (PubMed ID: 9608483)

  • 1. Evaluation of a new sealed reentrant well chamber for HDR and LDR brachytherapy calibrations.
    Pai S; Reinstein LE
    Med Phys; 1998 May; 25(5):719-21. PubMed ID: 9608483
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A parallel plate chamber for calibration of 192Ir LDR and HDR sources.
    Das KR; Kenny MB
    Med Phys; 1999 Nov; 26(11):2438-40. PubMed ID: 10587229
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The design of a new insert for calibration of LDR and HDR 192Ir sources in a well-type ionization chamber.
    Pineda AE; Alcón EP; deAlmeida CE
    Med Phys; 2003 Jul; 30(7):1566-8. PubMed ID: 12906174
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A radiation quality correction factor k for well-type ionization chambers for the measurement of the reference air kerma rate of (60)Co HDR brachytherapy sources.
    Schüller A; Meier M; Selbach HJ; Ankerhold U
    Med Phys; 2015 Jul; 42(7):4285-94. PubMed ID: 26133626
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Source geometry factors for HDR ¹⁹²Ir brachytherapy secondary standard well-type ionization chamber calibrations.
    Shipley DR; Sander T; Nutbrown RF
    Phys Med Biol; 2015 Mar; 60(6):2573-86. PubMed ID: 25761529
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Determination of absorbed dose in water at the reference point d(r0, theta0) for an 192Ir HDR brachytherapy source using a Fricke system.
    Austerlitz C; Mota HC; Sempau J; Benhabib SM; Campos D; Allison R; DeAlmeida CE; Zhu D; Sibata CH
    Med Phys; 2008 Dec; 35(12):5360-5. PubMed ID: 19175095
    [TBL] [Abstract][Full Text] [Related]  

  • 7. On the stability of well-type ionization chamber source strength calibration coefficients.
    Smith BR; DeWerd LA; Culberson WS
    Med Phys; 2020 Sep; 47(9):4491-4501. PubMed ID: 32434273
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In-air calibration of an HDR 192Ir brachytherapy source using therapy ion chambers.
    Patel NP; Majumdar B; Vijiyan V; Hota PK
    J Cancer Res Ther; 2005; 1(4):213-20. PubMed ID: 17998656
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Study of scattered radiation for in-air calibration by a multiple-distance method using ionization chambers and an HDR 192Ir brachytherapy source.
    Patel NP; Majumdar B; Vijayan V
    Br J Radiol; 2006 Apr; 79(940):347-52. PubMed ID: 16585730
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of a well-type ionization chamber for calibration of HDL and LDR brachytherapy sources.
    Ho AK; Sibata CH; deSouza CN; Castiglione R; Shin KH
    Med Dosim; 1995; 20(1):31-4. PubMed ID: 7794488
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Calibration of 192Ir high-dose-rate afterloading systems.
    Goetsch SJ; Attix FH; Pearson DW; Thomadsen BR
    Med Phys; 1991; 18(3):462-7. PubMed ID: 1870490
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A BrachyPhantom for verification of dose calculation of HDR brachytherapy planning system.
    Austerlitz C; Campos CA
    Med Phys; 2013 Nov; 40(11):112103. PubMed ID: 24320456
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Monte Carlo calculations of the ionization chamber wall correction factors for 192Ir and 60Co gamma rays and 250 kV x-rays for use in calibration of 192Ir HDR brachytherapy sources.
    Ferreira IH; de Almeida CE; Marre D; Marechal MH; Bridier A; Chavaudra J
    Phys Med Biol; 1999 Aug; 44(8):1897-904. PubMed ID: 10473203
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of scatter contribution and distance error by iterative methods for strength determination of HDR 192Ir brachytherapy source.
    Kumar S; Srinivasan P; Sharma SD; Subbaiah KV; Mayya YS
    Med Dosim; 2010; 35(3):230-7. PubMed ID: 19931038
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Replacement corrections of a Farmer-type ionization chamber for the calibration of Cs-137 and Ir-192 sources in a solid phantom.
    Steggerda MJ; Mijnheer BJ
    Radiother Oncol; 1994 Apr; 31(1):76-84. PubMed ID: 8041900
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Air-kerma strength determination of a 169Yb high dose rate brachytherapy source.
    VanDamme JJ; Culberson WS; DeWerd LA; Micka JA
    Med Phys; 2008 Sep; 35(9):3935-42. PubMed ID: 18841844
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Applications of the Italian protocol for the calibration of brachytherapy sources.
    Piermattei A; Azario L
    Phys Med Biol; 1997 Aug; 42(8):1661-9. PubMed ID: 9279913
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Calibration of multiple LDR brachytherapy sources.
    DeWerd LA; Micka JA; Holmes SM; Bohm TD
    Med Phys; 2006 Oct; 33(10):3804-13. PubMed ID: 17089845
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Experimental derivation of wall correction factors for ionization chambers used in high dose rate 192Ir source calibration.
    Maréchal MH; de Almeida CE; Ferreira IH; Sibata CH
    Med Phys; 2002 Jan; 29(1):1-5. PubMed ID: 11833542
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A simplified analytical approach to estimate the parameters required for strength determination of HDR 192Ir brachytherapy sources using a Farmer-type ionization chamber.
    Kumar S; Srinivasan P; Sharma SD; Mayya YS
    Appl Radiat Isot; 2012 Jan; 70(1):282-9. PubMed ID: 21872480
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.