These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 9623691)

  • 1. Nasal prongs in the detection of sleep-related disordered breathing in the sleep apnoea/hypopnoea syndrome.
    Ballester E; Badia JR; Hernández L; Farré R; Navajas D; Montserrat JM
    Eur Respir J; 1998 Apr; 11(4):880-3. PubMed ID: 9623691
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Nasal pressure recording in the diagnosis of sleep apnoea hypopnoea syndrome.
    Sériès F; Marc I
    Thorax; 1999 Jun; 54(6):506-10. PubMed ID: 10335004
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Evaluating oronasal flow with temperature (thermistor) and obstructive pressure (prongs)].
    Rühle KH; Fahrner A; Randerath W
    Pneumologie; 2001 Jan; 55(1):4-6. PubMed ID: 11236356
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of Apnea Detection Using Oronasal Thermal Airflow Sensor, Nasal Pressure Transducer, Respiratory Inductance Plethysmography and Tracheal Sound Sensor.
    Sabil A; Glos M; Günther A; Schöbel C; Veauthier C; Fietze I; Penzel T
    J Clin Sleep Med; 2019 Feb; 15(2):285-292. PubMed ID: 30736876
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Scoring respiratory events in paediatric patients: evaluation of nasal pressure and thermistor recordings separately and in combination.
    Verginis N; Davey MJ; Horne RS
    Sleep Med; 2010 Apr; 11(4):400-5. PubMed ID: 20189872
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Performance of nasal prongs in sleep studies : spectrum of flow-related events.
    Hernández L; Ballester E; Farré R; Badia JR; Lobelo R; Navajas D; Montserrat JM
    Chest; 2001 Feb; 119(2):442-50. PubMed ID: 11171721
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Detection of apnoeas, hypopnoeas and arousals by the AutoSet in the sleep apnoea/hypopnoea syndrome.
    Rees K; Wraith PK; Berthon-Jones M; Douglas NJ
    Eur Respir J; 1998 Oct; 12(4):764-9. PubMed ID: 9817142
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Noninvasive monitoring of respiratory mechanics during sleep.
    Farré R; Montserrat JM; Navajas D
    Eur Respir J; 2004 Dec; 24(6):1052-60. PubMed ID: 15572552
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Detection of respiratory events during NPSG: nasal cannula/pressure sensor versus thermistor.
    Norman RG; Ahmed MM; Walsleben JA; Rapoport DM
    Sleep; 1997 Dec; 20(12):1175-84. PubMed ID: 9493929
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of ResMed AutoSet (version 3.03) with polysomnography in the diagnosis of the sleep apnoea/hypopnoea syndrome.
    Gugger M
    Eur Respir J; 1997 Mar; 10(3):587-91. PubMed ID: 9072989
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of nasal pressure transducer and thermistor for detection of respiratory events during polysomnography in children.
    Budhiraja R; Goodwin JL; Parthasarathy S; Quan SF
    Sleep; 2005 Sep; 28(9):1117-21. PubMed ID: 16268381
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Forced oscillation measurements do not affect upper airway muscle tone or sleep in clinical studies.
    Badia JR; Farré R; Rigau J; Uribe ME; Navajas D; Montserrat JM
    Eur Respir J; 2001 Aug; 18(2):335-9. PubMed ID: 11529293
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Sleepwalking and sleep terrors in prepubertal children: what triggers them?
    Guilleminault C; Palombini L; Pelayo R; Chervin RD
    Pediatrics; 2003 Jan; 111(1):e17-25. PubMed ID: 12509590
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of partially attended night time respiratory recordings and full polysomnography in patients with suspected sleep apnoea/hypopnoea syndrome.
    Lloberes P; Montserrat JM; Ascaso A; Parra O; Granados A; Alonso P; Vilaseca I; Rodriguez-Roisin R
    Thorax; 1996 Oct; 51(10):1043-7. PubMed ID: 8977607
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of an auto-nCPAP device based on snoring detection.
    Lofaso F; Lorino AM; Duizabo D; Najafi Zadeh H; Theret D; Goldenberg F; Harf A
    Eur Respir J; 1996 Sep; 9(9):1795-800. PubMed ID: 8880093
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A novel device (SD-101) with high accuracy for screening sleep apnoea-hypopnoea syndrome.
    Agatsuma T; Fujimoto K; Komatsu Y; Urushihata K; Honda T; Tsukahara T; Nomiyama T
    Respirology; 2009 Nov; 14(8):1143-50. PubMed ID: 19818056
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Value of beat-to-beat blood pressure changes, detected by pulse transit time, in the management of the obstructive sleep apnoea/hypopnoea syndrome.
    Pitson DJ; Stradling JR
    Eur Respir J; 1998 Sep; 12(3):685-92. PubMed ID: 9762800
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Reciprocal interactions between spontaneous and respiratory arousals in adults with suspected sleep-disordered breathing.
    Tauman R; O'Brien LM; Barbé F; Iyer VG; Gozal D
    Sleep Med; 2006 Apr; 7(3):229-34. PubMed ID: 16564216
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Forced oscillation technique for the evaluation of severe sleep apnoea/hypopnoea syndrome: a pilot study.
    Badia JR; Farré R; Montserrat JM; Ballester E; Hernandez L; Rotger M; Rodriguez-Roisin R; Navajas D
    Eur Respir J; 1998 May; 11(5):1128-34. PubMed ID: 9648967
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Influence of moderate alcohol consumption on obstructive sleep apnoea with and without AutoSet nasal CPAP therapy.
    Teschler H; Berthon-Jones M; Wessendorf T; Meyer HJ; Konietzko N
    Eur Respir J; 1996 Nov; 9(11):2371-7. PubMed ID: 8947088
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.