BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

82 related articles for article (PubMed ID: 9627352)

  • 1. Enhanced accuracy and reproducibility in reporting of lung scintigrams by a segmental reference chart.
    Magnussen JS; Chicco P; Palmer AW; Mackey DW; Magee M; Murray IP; Bautovich G; Allman K; Storey G; Van der Wall H
    J Nucl Med; 1998 Jun; 39(6):1095-9. PubMed ID: 9627352
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Variability of perceived defect size in virtual lung scintigraphy.
    Magnussen JS; Chicco P; Palmer AW; Mackey DW; Magee M; Murray IP; Bautovich G; Allman K; Storey G; Van der Wall H
    J Nucl Med; 1998 Feb; 39(2):361-5. PubMed ID: 9476951
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Recognition of subsegmental scintigraphic defects in virtual lung scintigraphy.
    Chicco P; Magnussen JS; Mackey DW; Murray IP; van der Wall H
    Nucl Med Commun; 1997 Aug; 18(8):728-33. PubMed ID: 9293503
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Optimization of the scintigraphic segmental anatomy of the lungs.
    Magnussen JS; Chicco P; Palmer AW; Mackey DW; Magee M; Murray IP; Bautovich G; Allman K; Storey G; van der Wall H
    J Nucl Med; 1997 Dec; 38(12):1987-91. PubMed ID: 9430483
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Ventilation-perfusion lung scanning and the diagnosis of pulmonary embolism: improvement of observer agreement by the use of a lung segment reference chart.
    Lensing AW; van Beek EJ; Demers C; Tiel-van Buul MM; Yakemchuk V; van Dongen A; Coates G; Ginsberg JS; Hirsh J; ten Cate JW
    Thromb Haemost; 1992 Sep; 68(3):245-9. PubMed ID: 1440485
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Simulation of the stripe sign in a scintigraphic model of the lungs.
    Magnussen JS; Chicco P; Mackey DW; Murray IP; van der Wall H
    Nucl Med Commun; 1997 Jul; 18(7):648-54. PubMed ID: 9342103
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Observer variation in the interpretation of ventilation-perfusion lung scintigraphy.
    Kraemmer Nielsen H; Husted SE; Krusell LR; Charles P; Fasting H; Hansen HH
    Eur J Nucl Med; 1994 Feb; 21(2):103-7. PubMed ID: 8162931
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Single-photon emission tomography of a computerised model of pulmonary embolism.
    Magnussen JS; Chicco P; Palmer AW; Bush V; Mackey DW; Storey G; Magee M; Bautovich G; Van der Wall H
    Eur J Nucl Med; 1999 Nov; 26(11):1430-8. PubMed ID: 10552084
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Diagnostic imaging of acute pulmonary embolism.
    Christiansen F
    Acta Radiol Suppl; 1997; 410():1-33. PubMed ID: 9105183
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Interobserver and intraobserver variability in lung scan reading in suspected pulmonary embolism.
    Hoey JR; Farrer PA; Rosenthall LJ; Spengler RF
    Clin Nucl Med; 1980 Nov; 5(11):508-13. PubMed ID: 7438639
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The underestimation of segmental defect size in radionuclide lung scanning.
    Morrell NW; Nijran KS; Jones BE; Biggs T; Seed WA
    J Nucl Med; 1993 Mar; 34(3):370-4. PubMed ID: 8441025
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Ventilation-perfusion lung scintigraphy as a guide for pulmonary angiography in the localization of pulmonary emboli.
    Davey NC; Smith TP; Hanson MW; Lee VS; Stackhouse DJ; Coleman RE
    Radiology; 1999 Oct; 213(1):51-7. PubMed ID: 10540639
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Observer agreement and accuracy for lung scintigraphy: a comparison with pulmonary angiography.
    Christiansen F; Nilsson T; Måre K; Carlsson A
    Nucl Med Commun; 1997 Feb; 18(2):112-7. PubMed ID: 9076765
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Threshold of detection of diffuse lung disease.
    Chicco P; Magnussen JS; Palmer AW; Mackey DW; Van der Wall H
    J Nucl Med; 1999 Jan; 40(1):85-90. PubMed ID: 9935062
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Prospective validation of the stripe sign in ventilation-perfusion scintigraphy.
    Sostman HD; Gottschalk A
    Radiology; 1992 Aug; 184(2):455-9. PubMed ID: 1620847
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The anatomy of radioisotope lung scanning.
    Morrell NW; Roberts CM; Jones BE; Nijran KS; Biggs T; Seed WA
    J Nucl Med; 1992 May; 33(5):676-83. PubMed ID: 1569475
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Interpretation of indeterminate lung scintigrams.
    Biello DR; Mattar AG; Osei-Wusu A; Alderson PO; McNeil BJ; Siegel BA
    Radiology; 1979 Oct; 133(1):189-94. PubMed ID: 472290
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Pulmonary embolism: prospective comparison of spiral CT with ventilation-perfusion scintigraphy.
    Mayo JR; Remy-Jardin M; Müller NL; Remy J; Worsley DF; Hossein-Foucher C; Kwong JS; Brown MJ
    Radiology; 1997 Nov; 205(2):447-52. PubMed ID: 9356627
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Anatomic distribution of pulmonary emboli at pulmonary angiography: implications for cross-sectional imaging.
    Oser RF; Zuckerman DA; Gutierrez FR; Brink JA
    Radiology; 1996 Apr; 199(1):31-5. PubMed ID: 8633168
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Experience with routine use of combined inhalation-perfusion lung scintigraphy. The most reliable diagnosis of pulmonary embolism].
    Bajnok L; Varga J; Pásztor T; Nagy J
    Orv Hetil; 1993 Feb; 134(7):355-8. PubMed ID: 8430021
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.