132 related articles for article (PubMed ID: 9627853)
1. Influence of acquisition parameters on hemodynamic measurements with the Heidelberg Retina Flowmeter at the optic disc.
Bohdanecka Z; Orgül S; Prünte C; Flammer J
J Glaucoma; 1998 Jun; 7(3):151-7. PubMed ID: 9627853
[TBL] [Abstract][Full Text] [Related]
2. Reproducibility of retinal and optic nerve head blood flow measurements with scanning laser Doppler flowmetry.
Nicolela MT; Hnik P; Schulzer M; Drance SM
J Glaucoma; 1997 Jun; 6(3):157-64. PubMed ID: 9211138
[TBL] [Abstract][Full Text] [Related]
3. Observer interpretation variability of peripapillary flow using the Heidelberg Retina Flowmeter.
Iester M; Ciancaglini M; Rolle T; Vattovani O
Eye (Lond); 2006 Nov; 20(11):1246-53. PubMed ID: 16254592
[TBL] [Abstract][Full Text] [Related]
4. Decreased Heidelberg Retina Flowmeter (HRF) parameter "flow" at the papilla shortly after smoking a cigarette.
Lietz-Partzsch A; Griesser SM; Flammer J; Haefliger IO
Klin Monbl Augenheilkd; 2001 May; 218(5):332-4. PubMed ID: 11417328
[TBL] [Abstract][Full Text] [Related]
5. Confocal scanning laser Doppler flowmetry: experiments in a model flow system.
Chauhan BC; Smith FM
J Glaucoma; 1997 Aug; 6(4):237-45. PubMed ID: 9264303
[TBL] [Abstract][Full Text] [Related]
6. [Confocal scanning laser Doppler retinal flowmetry in normal eyes].
Li J; Chu R; Sun X; Shen Y
Zhonghua Yan Ke Za Zhi; 1999 Sep; 35(5):373-5. PubMed ID: 11835843
[TBL] [Abstract][Full Text] [Related]
7. Optic nerve head neuroretinal rim blood flow differences in monkeys with laser-induced glaucoma.
Brooks DE; Kallberg ME; Komaromy AM; Ollivier FJ; Lambrou GN
Vet Ophthalmol; 2005; 8(2):113-9. PubMed ID: 15762924
[TBL] [Abstract][Full Text] [Related]
8. Improved interpretation of flow maps obtained by scanning laser Doppler flowmetry using a rat model of retinal artery occlusion.
Yu DY; Townsend R; Cringle SJ; Chauhan BC; Morgan WH
Invest Ophthalmol Vis Sci; 2005 Jan; 46(1):166-74. PubMed ID: 15623770
[TBL] [Abstract][Full Text] [Related]
9. [Application of confocal scanning laser Doppler retinal flowmetry in the measurement of fundus blood flow parameters after retinal detachment surgery].
Chen S; Han M; Zhang L; Zhang S; Wang L; Wei J
Zhonghua Yan Ke Za Zhi; 2002 Mar; 38(3):140-3. PubMed ID: 11955316
[TBL] [Abstract][Full Text] [Related]
10. Reproducibility of pixel-by-pixel analysis of Heidelberg retinal flowmetry images: the Thessaloniki Eye Study.
Mavroudis L; Harris A; Topouzis F; Wilson MR; Yu F; Anastasopoulos E; Koskosas A; Siesky B; Pappas T; Founti P; Coleman AL
Acta Ophthalmol; 2008 Feb; 86(1):81-6. PubMed ID: 17850404
[TBL] [Abstract][Full Text] [Related]
11. Heidelberg retina flowmeter parameters at the papilla in healthy subjects.
Griesser SM; Lietz A; Orgül S; Schötzau A; Hendrickson P; Flammer J; Haefliger IO
Eur J Ophthalmol; 1999; 9(1):32-6. PubMed ID: 10230589
[TBL] [Abstract][Full Text] [Related]
12. Reproducibility of the Heidelberg retinal flowmeter in determining low perfusion areas in peripapillary retina.
Jonescu-Cuypers CP; Harris A; Wilson R; Kagemann L; Mavroudis LV; Topouzis F; Coleman AL
Br J Ophthalmol; 2004 Oct; 88(10):1266-9. PubMed ID: 15377548
[TBL] [Abstract][Full Text] [Related]
13. Principle, validity, and reliability of scanning laser Doppler flowmetry.
Michelson G; Schmauss B; Langhans MJ; Harazny J; Groh MJ
J Glaucoma; 1996 Apr; 5(2):99-105. PubMed ID: 8795741
[TBL] [Abstract][Full Text] [Related]
14. Reproducibility of retinal and optic nerve head perfusion measurements using scanning laser Doppler flowmetry.
Hafez AS; Bizzarro RL; Rivard M; Trabut I; Lovasik JV; Kergoat H; Lesk MR
Ophthalmic Surg Lasers Imaging; 2003; 34(5):422-32. PubMed ID: 14509472
[TBL] [Abstract][Full Text] [Related]
15. [2-dimensional mapping and retinal and papillary microcirculation using scanning laser Doppler flowmetry].
Michelson G; Groh M; Langhans M; Schmauss B
Klin Monbl Augenheilkd; 1995 Sep; 207(3):180-90. PubMed ID: 7474787
[TBL] [Abstract][Full Text] [Related]
16. Confocal laser Doppler flowmeter measurements in a controlled flow environment in an isolated perfused eye.
Townsend R; Cringle SJ; Morgan WH; Chauhan BC; Yu DY
Exp Eye Res; 2006 Jan; 82(1):65-73. PubMed ID: 15993409
[TBL] [Abstract][Full Text] [Related]
17. [Evaluation analysis of blood flow of peripapillary area in glaucoma patients using scanning laser Doppler flowmetry].
Nizankowska MH; Jamrozy-Witkowska A; Asejczyk M
Klin Oczna; 2002; 104(3-4):201-6. PubMed ID: 12608300
[TBL] [Abstract][Full Text] [Related]
18. Interobserver repeatability of heidelberg retinal flowmetry using pixel-by-pixel analysis.
Zion IB; Harris A; Moore D; Werne A; Ralstin M; Siesky B; McCranor L; Rospigliosi C; Steinmann W; Katz LJ; Garzozi HJ
J Glaucoma; 2009; 18(4):280-3. PubMed ID: 19365191
[TBL] [Abstract][Full Text] [Related]
19. Retinal blood flow measurements and neuroretinal rim damage in glaucoma.
Logan JF; Rankin SJ; Jackson AJ
Br J Ophthalmol; 2004 Aug; 88(8):1049-54. PubMed ID: 15258023
[TBL] [Abstract][Full Text] [Related]
20. Hemodynamic evaluation of the optic nerve head in cerebral autosomal dominant arteriopathy with subcortical infarcts and leukoencephalopathy.
Rufa A; Dotti MT; Frezzotti P; De Stefano N; Caporossi A; Federico A
Arch Neurol; 2004 Aug; 61(8):1230-3. PubMed ID: 15313839
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]