These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
165 related articles for article (PubMed ID: 9631640)
21. A clinical evaluation of the Camino subdural screw and ventricular monitoring kits. Chambers IR; Mendelow AD; Sinar EJ; Modha P Neurosurgery; 1990 Mar; 26(3):421-3. PubMed ID: 2320210 [TBL] [Abstract][Full Text] [Related]
22. The Presence of Blood in a Strain Gauge Pressure Transducer Has a Clinical Effect on the Accuracy of Intracranial Pressure Readings. Nairon EB; Joseph J; Kamal A; Busch DR; Olson DM Crit Care Explor; 2024 May; 6(5):e1089. PubMed ID: 38728059 [TBL] [Abstract][Full Text] [Related]
23. [Ventricular fluid pressure measurement by microcatheter and pressure-controlled external fluid drainage (author's transl)]. Richard KE Acta Neurochir (Wien); 1977; 38(1-2):73-87. PubMed ID: 899897 [TBL] [Abstract][Full Text] [Related]
24. Erroneous intracranial pressure measurements from simultaneous pressure monitoring and ventricular drainage catheters. Birch AA; Eynon CA; Schley D Neurocrit Care; 2006; 5(1):51-4. PubMed ID: 16960297 [TBL] [Abstract][Full Text] [Related]
25. Laboratory testing of three intracranial pressure microtransducers: technical report. Czosnyka M; Czosnyka Z; Pickard JD Neurosurgery; 1996 Jan; 38(1):219-24. PubMed ID: 8747977 [TBL] [Abstract][Full Text] [Related]
26. Methods of experimental and clinical assessment of the relative measurement accuracy of an intracranial pressure transducer. Technical note. Morgalla MH; Krasznai L; Dietz K; Mettenleiter H; Deininger M; Grote EH J Neurosurg; 2001 Sep; 95(3):529-32. PubMed ID: 11565881 [TBL] [Abstract][Full Text] [Related]
27. ICP Monitoring by Open Extraventricular Drainage: Common Practice but Not Suitable for Advanced Neuromonitoring and Prone to False Negativity. Hockel K; Schuhmann MU Acta Neurochir Suppl; 2018; 126():281-286. PubMed ID: 29492575 [TBL] [Abstract][Full Text] [Related]
28. The evaluation of the wave-form analysis capability of a new strain-gauge intracranial pressure MicroSensor. Piper IR; Miller JD Neurosurgery; 1995 Jun; 36(6):1142-4; discussion 1144-5. PubMed ID: 7643994 [TBL] [Abstract][Full Text] [Related]
30. Experimental evaluation of the Spiegelberg intracranial pressure and intracranial compliance monitor. Technical note. Yau YH; Piper IR; Clutton RE; Whittle IR J Neurosurg; 2000 Dec; 93(6):1072-7. PubMed ID: 11117854 [TBL] [Abstract][Full Text] [Related]
31. Are External Ventricular Drains Better than Parenchymal Intracranial Pressure Monitors in Trauma Patients? Valadka AB World Neurosurg; 2015 Aug; 84(2):211-3. PubMed ID: 25725163 [No Abstract] [Full Text] [Related]
32. ICP measurement accuracy: the effect of temperature drift. Design of a laboratory test for assessment of ICP transducers. Morgalla MH; Mettenleiter H; Katzenberger T J Med Eng Technol; 1999; 23(1):10-4. PubMed ID: 10202697 [TBL] [Abstract][Full Text] [Related]
33. A clinical study of parenchymal and subdural miniature strain-gauge transducers for monitoring intracranial pressure. Gray WP; Palmer JD; Gill J; Gardner M; Iannotti F Neurosurgery; 1996 Nov; 39(5):927-31; discussion 931-2. PubMed ID: 8905747 [TBL] [Abstract][Full Text] [Related]
34. [Percutaneous revision of shunt with obstructed ventricular catheter (author's transl)]. Ono H; Moriyama T; Uneoka K; Matsumura H; Fujita Y No Shinkei Geka; 1976 Apr; 4(4):365-70. PubMed ID: 944878 [TBL] [Abstract][Full Text] [Related]
36. The role of permanent invasive monitoring of intracranial pressure in the treatment of infants with posthaemorrhagic ventricular dilatation after intraventricular haemorrhage (case report). Tsirkvadze I; Chkhaidze M; Pruidze D; Nizharadze G; Kanjaradze D Georgian Med News; 2010 Apr; (181):55-8. PubMed ID: 20495227 [TBL] [Abstract][Full Text] [Related]
37. External Ventricular Drains versus Intraparenchymal Intracranial Pressure Monitors in Traumatic Brain Injury: A Prospective Observational Study. Liu H; Wang W; Cheng F; Yuan Q; Yang J; Hu J; Ren G World Neurosurg; 2015 May; 83(5):794-800. PubMed ID: 25541084 [TBL] [Abstract][Full Text] [Related]
38. A proposal method for the assessment of cerebrospinal fluid pressure in the cerebral ventricles. Cicchiello LR J Neurosurg Sci; 1979; 23(4):311-14. PubMed ID: 548578 [TBL] [Abstract][Full Text] [Related]
39. Intracranial pressure monitoring and outcome in traumatic brain injury: the probe does matter? Servadei F; Picetti E World Neurosurg; 2015 May; 83(5):732-3. PubMed ID: 25659804 [No Abstract] [Full Text] [Related]
40. [Effects of hyperoxia, glycerol and ventricular drainage on ICP and CBF in patients with increased ICP due to CSF circulatory-absorbance disturbance]. Ohta H; Suzuki E; Hinuma Y; Kawamura S; Nemoto M; Hadeishi H No To Shinkei; 1987 Mar; 39(3):273-9. PubMed ID: 3580214 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]