These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

103 related articles for article (PubMed ID: 9638713)

  • 1. Clinical evaluation of a new generation membrane oxygenator: a prospective randomized study.
    Stammers AH; Fristoe LW; Alonso A; Song Z; Galbraith T
    Perfusion; 1998 May; 13(3):165-75. PubMed ID: 9638713
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A clinical evaluation of platelet function, haemolysis and oxygen transfer during cardiopulmonary bypass comparing the Quantum HF-6700 to the HF-5700 hollow fibre membrane oxygenator.
    Chukwuemeka AO; Turtle MR; Trivedi UH; Venn GE; Chambers DJ
    Perfusion; 2000 Nov; 15(6):479-84. PubMed ID: 11131210
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical evaluation of the Admiral 1.35m2 hollow-fibre membrane oxygenator.
    Issitt R; Cumberland T; Clements A; Mulholland J
    Perfusion; 2008 Jan; 23(1):33-8. PubMed ID: 18788215
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Clinical evaluation of the Bentley Univox membrane oxygenator.
    Nowak J; Pols G; Brands W; Rosseel P
    Perfusion; 1992 Jan; 7(1):59-65. PubMed ID: 10147700
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of the performance characteristics of three generations of membrane oxygenators: Univoxregistered, Univoxreqistered Goldtrademark and SpiralGoldtrademark.
    Beckley PD; Morris SM; Smith JJ; McNamara JL; Novak JA
    Perfusion; 1996 Jan; 11(1):61-70. PubMed ID: 8904329
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Clinical evaluation of a new hollow fibre membrane oxygenator.
    De Somer F; De Smet D; Vanackere M; Van Nooten G; Caes F; Delanghe J
    Perfusion; 1994 Jan; 9(1):57-64. PubMed ID: 8161869
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of three commercially available hollow fiber oxygenators: gas transfer performance and biocompatibility.
    de Vroege R; Wagemakers M; te Velthuis H; Bulder E; Paulus R; Huybregts R; Wildevuur W; Eijsman L; van Oeveren W; Wildevuur C
    ASAIO J; 2001; 47(1):37-44. PubMed ID: 11199313
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Clinical evaluation of nine hollow-fibre membrane oxygenators.
    Segers PA; Heida JF; de Vries I; Maas C; Boogaart AJ; Eilander S
    Perfusion; 2001 Mar; 16(2):95-106. PubMed ID: 11334201
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Clinical evaluation of minimized extracorporeal circulation in high-risk coronary revascularization: impact on air handling, inflammation, hemodilution and myocardial function.
    Gunaydin S; Sari T; McCusker K; Schonrock U; Zorlutuna Y
    Perfusion; 2009 May; 24(3):153-62. PubMed ID: 19755462
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Silicone-coated polypropylene hollow-fiber oxygenator: experimental evaluation and preliminary clinical use.
    Shimono T; Shomura Y; Hioki I; Shimamoto A; Tenpaku H; Maze Y; Onoda K; Takao M; Shimpo H; Yada I
    Ann Thorac Surg; 1997 Jun; 63(6):1730-6. PubMed ID: 9205175
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Prolonged extracorporeal membrane oxygenation in sheep with a hollow-fiber oxygenator and a centrifugal pump.
    Palder SB; Shaheen KW; Whittlesey GC; Nowlen TT; Kundu SK; Klein MD
    ASAIO Trans; 1988; 34(3):820-2. PubMed ID: 3196606
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A clinical evaluation of the Terumo Capiox SX18R hollow fiber oxygenator.
    Dekkers PA; Lawson DS; Smigla GR; Shearer IR
    J Extra Corpor Technol; 1995 Sep; 27(3):152-7. PubMed ID: 10155360
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Clinical evaluation of six hollow-fibre membrane oxygenators.
    Visser C; de Jong DS
    Perfusion; 1997 Nov; 12(6):357-68. PubMed ID: 9413848
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of a New Miniaturized Extracorporeal Membrane Oxygenation System With Integrated Rotary Blood Pump to a Standard System in a Porcine Model of Acute Lung Injury.
    Pilarczyk K; Heckmann J; Lyskawa K; Strauß A; Haake N; Wiese I; Jakob H; Kamler M; Pizanis N
    Artif Organs; 2016 Jul; 40(7):645-58. PubMed ID: 26636760
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Deleterious effects of cardiopulmonary bypass. A prospective study of bubble versus membrane oxygenation.
    van Oeveren W; Kazatchkine MD; Descamps-Latscha B; Maillet F; Fischer E; Carpentier A; Wildevuur CR
    J Thorac Cardiovasc Surg; 1985 Jun; 89(6):888-99. PubMed ID: 3158783
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A pulsatile cardiopulmonary bypass system that prevents negative pressure at the membrane oxygenator.
    Komoda T; Maeta H; Imawaki S; Shiraishi Y; Arioka I; Fukunaga S; Tanaka S; Nasu N
    ASAIO J; 1993; 39(4):936-41. PubMed ID: 8123931
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Experimental evaluation of the Medtronic Maxima Forté hollow fiber membrane oxygenator.
    Mueller XM; Tevaearai HT; Augstburger M; Horisberger J; von Segesser LK
    J Extra Corpor Technol; 1998 Sep; 30(3):115-9. PubMed ID: 10339286
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Preclinical evaluation of a hollow fiber silicone membrane oxygenator for extracorporeal membrane oxygenator application.
    Maeda T; Iwasaki A; Kawahito S; Nakata K; Nonaka K; Linneweber J; Schulte-Eistrup S; Takano T; Yoshikawa M; Sato K; Kuwana J; Murabayashi S; Nosé Y
    ASAIO J; 2000; 46(4):426-30. PubMed ID: 10926139
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of hollow-fiber membrane oxygenators in terms of pressure drop of the membranes during normothermic and hypothermic cardiopulmonary bypass in neonates.
    Undar A; Owens WR; McGarry MC; Surprise DL; Kilpack VD; Mueller MW; McKenzie ED; Fraser CD
    Perfusion; 2005 May; 20(3):135-8. PubMed ID: 16038384
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Impact of hollow-fiber membrane surface area on oxygenator performance: Dideco D903 Avant versus a prototype with larger surface area.
    Mueller XM; Tevaearai HT; Jegger D; Boone Y; Augstburger M; von Segesser LK
    J Extra Corpor Technol; 2000 Sep; 32(3):152-7. PubMed ID: 11146960
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.